| Plan Review Stops For Permit 00051008 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2000-12-13 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-12-13 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2000-08-24 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-08-24 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLANS ARE READY ISSUANCE, | | | PAY CITY RADON AND COUNTY IMPACT FEES, | | | HAVE ZONING APPROVAL, |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-08-11 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-08-11 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 2ND REVIEW[BUILDING] | | | | | | SHEET RF-01 DETAIL "A",PARAPET SHALL BE | | | OF NON COMBUSTIBLE MATERIAL[TABLE 600 | | | AND 1517.6]. | | | | | | SUBMIT SPECIFICATION FOR EXTERIOR WALL, | | | [3HR AND 2HR] REQUIRED BY TABLE 600 SBC. | | | | | | | | | REVIEWED BY: | | | LUIS MARTINEZ | | | 659-8096#8456 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-07-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-07-22 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************BUILDING************* | | | | | | 1]ALL EXTERIOR WALLS SHALL COMPLY WITH | | | TABLE 600,SBC,REQUIREMENTS.SUBMIT | | | APPROVED TESTED ASSEMBLY'S FOR 3HR WALL | | | INCLUDE MIN. 18" PARAPET. NO OPENINGS | | | ARE PERMITED WERE SPERATIONS OF LESS | | | THAN 3' EXIST BETWEEN PROPERTY LINES OR | | | OTHER BUILDINGS. | | | 2]SUBMIT COMPLETE CONSTRUCTION DETAILS | | | FOR CONNECTION TO EXISTING BUILDING. | | | 3]PROVIDE ROOF DRAINAGE PLAN. | | | 4]A 2ND APPROVED EXIT IS REQUIRED,1004.2 | | | SBC. | | | 5]SUBMIT INTERIOR WALL SECTION. | | | 6]ADDITIONAL FEES OWED,COUNTY IMPACT FEE | | | AND CITY RADON FEE. | | | | | | | | | | | | REVIEWED BY: | | | LUIS MARTINEZ | | | 659-8096#8456 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-10 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-10 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-07-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-05 |
Time |
21:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-05 |
Time |
21:23 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** PROVISO **************** | | | | | | 1)NOTE: YOU HAVE SUBMITTED THE AIC RAT- | | | -ING FOR BRANCH BREAKERS. HOW-EVER THE | | | AIC RATING FOR MAIN IS REQ`D ALSO. MUST | | | BE RATED FOR THE AVAILABLE FAULT CURRENT | | | PER 110-9. | | | | | | 2)NOTE: PLEASE SHOW ALL BRANCH CIRCUIT | | | #`S ON PLANS/ CORRELATE WITH PANEL SCHE- | | | -DULE. | | | | | | 3)NOTE PLEASE SUBMIT LOAD CALCULATION | | | WITH ALL CONTINUOUS LOADS FIGURED AT | | | 125% (LIGHTING). | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-08-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-10 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-07-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-07-11 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) PROVIDE EMERGENCY LIGHTING AND EXIT | | | SIGNS. | | | 2) PROVIDE AT LEAST TWO MEANS OF EGRESS | | | FROM STORAGE BUILDING. | | | 3) ACCORDING TO PERSONS, THE BUILDING | | | IS TO BE USED FOR STORAGE OR ORNAMENTAL | | | METAL. THEY WERE EXPLAINED ABOUT EXITING | | | REQUIREMENTS AND THAT OVERHEAD DOORS | | | CANNOT BE USED FOR EXITING. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-07-14 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-14 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
cthirben |
Date |
2000-07-14 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO********************************* | | | PROVIDE VENTILATION TO THE BATHROOM AS | | | PER 1997 SMC 503.3.1.. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-07-11 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-11 |
Time |
08:29 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-07-11 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-12-13 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-05-22 |
Time |
16:32 |
Rev Time |
0.25 |
| Received By |
nleiva |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NEEDS LEVEL 1 SITE PLAN REVIEW |
|
|