Plan Review Details - Permit 00050907
Plan Review Stops For Permit 00050907
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2001-01-26 Cont ID  
Sent By hpiskura Date 2001-01-25 Time 11:23 Rev Time 0.00
Received By hpiskura Date 2001-01-25 Time 11:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2001-01-12 Cont ID  
Sent By hpiskura Date 2001-01-12 Time 14:39 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2000-11-09 Cont ID  
Sent By drunnels Date 2000-11-09 Time 10:10 Rev Time 1.00
Received By drunnels Date 2000-11-09 Time 10:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2000-09-28 Cont ID  
Sent By lmartine Date 2000-09-28 Time 15:48 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00BUILDING COMMENTS
 -------------------
  
 PLEASE REFER TO ORIGINAL COMMENTS
  
 1] C0MMENTS 1THRU4 HAVE COMPLIED.
 2] COMMENT #5, DOOR SCHEDULE DOES NOT
 REFLECT HOURLY RATINGS.
 3] COMMENT #6,7 AND 8 HAVE COMPLIED.
 4] COMMENT #9, SPRINKLER LAYOUT IN PATIO
 STILL NOT PROVIDED.
  
  
  
 REVIEWED BY:
 LUIS MARTINEZ
 561-659-8096
 EXT: #8456

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-06-28 Cont ID  
Sent By lmartine Date 2000-06-28 Time 14:58 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00*****BUILDING REVIEW COMMENTS*****
  
 1]SUBMIT PRODUCT TESTS FOR ANY NEW EXTER
 IOR DOORS AND WINDOWS,PROVIDE IMPACT
 PROTECTION METHOD FOR EXTERIOR GLAZING
 2]ENERGY CALCULATIONS ARE REQUIRED.
 3]SPECIFY ALL HAZARDOUS LOCATIONS FOR
 GLAZING,SEE 2405.2,SBC.
 4]TABLE 1004,SBC,REQUIRES CORRIDOR AND
 ISLE WIDTH TO BE MIN.44"CLEAR,FOR
 OCCUPANCY OVER 50 PERSONS.
 5]CLERIFY [B] RATING FOR DOORS 121A AND
 121B,ALSO DOOR 121B SHALL PROVIDE 18"
 CLEAR ON PULL SIDE OF HANDLE.
 6]PROVIDE ACCESSIBLE SEATING AT PATIO.
 7]SUBMIT EXITING CALCULATIONS FOR # OF
 PERSONS EXITING FROM THE RESTAURANTS
 AND THE BUILDING THRU THE VESTIBULE.
 8]HEALTH DEPARTMENT APPROVAL REQUIRED.
 9]SUBMIT FIRE SPRINKLER LAYOUT,PATIO
 SEATING AREA MUST BE PROTECTED.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-09-19 Cont ID  
Sent By dpalmer Date 2000-09-19 Time 20:04 Rev Time 0.00
Received By dpalmer Date 2000-09-19 Time 20:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-06-05 Cont ID  
Sent By dpalmer Date 2000-06-05 Time 20:33 Rev Time 0.00
Received By dpalmer Date 2000-06-05 Time 20:33 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE: PLEASE SUBMIT THE AIC RATINGS
 OF 600 AMP DISC AND 700AMP BREAKER.
 MAINS MUST BE RATED FOR THE AVAILABLE
 FAULT CURRENT.MUST BE PLANS 215-5
  
 2)NOTE: PLEASE NOTE AS PER LOCAL CODE
 OUTLET SPACING TO BE EVERY 20` OF
 UNENCUMBERED WALL SPACE. 210-50 SEE E-3
 CLOUDED AREA .
  
 3)NOTE: PLEASE NOTE ART 450-21B FOR
 TRANSFORMER ROOM REQ`MENTS.
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL 561-659-8096 EXT 8372
  
  
 PLEASE SHOW CHEFS PANEL LOCATION.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-06-19 Cont ID  
Sent By rturnque Date 2000-06-19 Time 09:49 Rev Time 1.00
Received By rturnque Date   Time   Sent To  
Notes
2001-01-08 00:00:00FIRE ALARM SYSTEM SHALL BE CLASS "A" OR
 ADDRESSABLE.
  
 HOOD EXTINGUISHING SYSTEM SHALL BE
 INTERCONNECTED WITH FIRE ALARM SYSTEM.
  
 INTERIOR FINISH SHALL BE CLASS A OR B.
  
 PROVIDE AN APPROVED,RATED CURTAIN IN THE
 DOORWAY OF THE PRIVATE ROOM. CURTAIN
 SHALL BE IN ACCORDANCE WITH NFPA 701.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-12-21 Cont ID  
Sent By ndenmark Date 2000-12-21 Time 11:22 Rev Time 0.25
Received By ndenmark Date 2000-12-21 Time 11:22 Sent To  
Notes
2001-01-08 00:00:00NO CHANGES TO PREVIOUSLY REVIEWED PLANS

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-09-14 Cont ID  
Sent By ndenmark Date 2000-09-14 Time 11:20 Rev Time 1.00
Received By ndenmark Date 2000-09-14 Time 11:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-06-09 Cont ID  
Sent By ndenmark Date 2000-06-09 Time 13:57 Rev Time 1.00
Received By ndenmark Date 2000-06-09 Time 13:57 Sent To  
Notes
2001-01-08 00:00:00***********DENIED**********************
 1) AIR CONDITIONING AND AIR BALANCE OK
  
 2) PROVIDE DETAIL ON KITCHEN GREASE EX-
 HAUST DUCT PATH OF TRAVEL FROM KITCHEN
 TO OUTSIDE OF BUILDING
  
 1997 SMC 505.9.1 VERTICAL AND HORIZONTAL
 DUCTS LOCATED IN BUILDINGS TWO OR MORE
 STORIES SHALL BE ENCLOSED IN A CONTIN-
 UOUS ENCLOSURE FROM THE CEILING ABOVE
 THE HOOD TO OR THROUGH THE ROOF.
 SMC 505.9.2 REQUIRES THE ENCLOSURE TO BE
 USED EXCLUSIVELY FOR A SINGLE GREASE
 EXHAUST SYSTEM ANS SHALL BE USED FOR NO
 OTHER PURPOSE.
 NOTE: SEPARATE PERMITS REQUIRED FOR HOOD
 WALK-IN COOLER/FREEZER AND FIRE SUPPRES-
 SION FOR HOODS

Review Stop P PLUMBING
Rev No 5 Status P Date 2000-12-19 Cont ID  
Sent By jleech Date 2000-12-19 Time 08:50 Rev Time 1.50
Received By jleech Date 2000-12-19 Time 08:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2000-11-15 Cont ID  
Sent By jleech Date 2000-11-15 Time 12:16 Rev Time 3.00
Received By jleech Date 2000-11-15 Time 12:16 Sent To  
Notes
2001-01-08 00:00:001.STOP GAS RISER AT METER. DELETE GAS
 SERVICE LINE AND COMMENT.
 2.TOTAL BTU'S TOTAL 1,389,000 3" PIPE
 REQUIRED FROM METER TO FIRST DROP.
 SHT. P-2 GAS PIPE SHOWN 3" ISO. SHOWS
 2 1/2"
 3.LIST GAS PIPE TYPE TO BE INSTALLED.
 4.SUBMIT MANUF. SHEETS FOR ALL GAS
 EQUIPMENT.
 5.CALCULATIONS FOR COMBUSTION AIR
 REQUIRED FOR WATER HEATERS.
 6.HANDYCAP STALLS DOES NOT COMPLY WITH
 FACBC SEC 4.17.3 AND FIG. 30
 7.CANNOT LOCATE DPR APPROVAL.
 8.W.H. VAC.BRACKER TO BE PIPED ABOVE
 WATER HEATERS.
 9.WASTE FROM 3 COMPARTMENT SINK IN
 BAR AREA TO BE PIPED TO GREASE INTER-
 CEPTOR.

Review Stop P PLUMBING
Rev No 3 Status F Date 2000-09-15 Cont ID  
Sent By tlarge Date 2000-09-15 Time 18:30 Rev Time 3.00
Received By tlarge Date 2000-09-15 Time 10:43 Sent To  
Notes
2001-01-08 00:00:001)SHT.A0-THE APPLICABLE PLUMBING CODE
 IS THE 1994 EDITION OF THE STANDARD
 PLUMBING CODE,NOT 1997.
  
 2)SHOW THE CLEAR INSIDE DIMENSIONS(LXW)
 OF THE HANDICAP STALLS.COMPLY W/FACBC
 SEC.4.17.3,& FIG.30.
  
 3)SUBMIT CALCULATIONS FOR COMBUSTION AIR
 FOR THE WATER HEATERS.SGC SEC.402.4.,
 402.4.4.
  
 4)SUBMIT DETAIL OF GAS VENT.SHOW TYPE,
 TERMINATION AND SIZE.SEE ATTACHED REQS.
 SUBMIT DETAILS FOR THE AIR INTAKE AND
 EXHAUST SYSTEMS FOR THE WATER HEATERS.
 COMPLY W/SGC CHAPT.6.SEE SHT.P-3.
  
 5)CONTROLS FOR GAS EQUIPMENT SHALL
 COMPLY W/NFPA 5.5.4.,SGC SEC.310.1.A
 MANUAL SHUT-OFF VALVE AND UNION SHALL BE
 INSTALLED AT CONTROLS FOR REMOVAL AND
 REPLACEMENT.VALVES SHALL BE LOCATED
 BELOW CEILING.
  
 6)WATER SUPPLY CONTROL SHALL COMPLY W/
 SPC SEC.610.4.2.(S.O.V.IS REQD.ON WATER
 SUPPLY BRANCH FROM MAIN.)
  
 7)CONTACT R.COMPO W/CITY OF WPB
 UTILITIES FOR CHANGES TO THE GREASY
 WASTE SYSTEM.(SUBMIT APPROVAL FROM
 UTILITIES FOR GREASE TRAP.)
  
 8)A FLOOR SINK IN LIEU OF THE FLOOR
 DRAIN SHALL BE INSTALLED TO RECEIVE THE
 DISCHARGE FROM THE P & T VALVE FROM THE
 WATER HEATER.SPC SEC.804.1,807.1.3.
  
 9)A VACUUM RELIEF VALVE IS REQD.ON
 BOTTOM FED WATER HEATERS PER SPC.507.1.2
  
 10)SHT.P-4-NOT MORE THAN 2 FIXTURES
 SHALL BE SUPPLIED BY 1/2" CW LINE.
 COUNTYWIDE AMENDMENTS TO SPC SEC.607.7.
  
 11)SHT.P-4-THE APPLICABLE GAS CODE IN
 EFFECT IN THE CITY OF WPB IS THE 1997
 STANDARD GAS CODE,NOT HTE 1994 EDITION.
  
 12)SHT.P-4-CLARIFY PSI FOR THE GAS
 SYSTEM.PLANS NOTE 25 PS1.THIS CANNOT BE
 CORRECT AS DESIGNED.COUNTYWIDE AMENDMENT
 TO SPC SEC.104.2.1.
  
 13)DISCHARGE OF EFFLUENT TO SANITARY
 SYSTEM SHALL NOT EXCEED 140 DEGREES
 UNLESS PROPER COOLING METHODS ARE
 INCORPORATED.SPC SEC.717.8.
  
 14.)DISHWASHER CANNOT DISCHARGE TO THE
 GREASY WASTE SYSTEM PER LOCAL ORDINANCE.
 DISCHARGE SHALL BE TO THE SANITARY
 SYSTEM.
  
 15)SHT.A-8-MEN'S TOILET ROOM-THE DOOR ON
 THE HANDICAP STALL SHALL NOT SWING INTO
 THE CLEAR FLOOR SPACE REQD.FOR THE LAV.
 COMPLY W/FACBC SEC.4.22.2.(SEE SHT.P-2
 ALSO).
  
 16)SIZE THE GAS LINES TO THE APPLIANCE.
 COMPLY W/TABLE 305.4(A).
  
 18)SUBMIT MANUF.SHEETS FOR GAS EQUIPMENT
 EQUIPMENT SHALL BE LISTED PER SGC SEC.
 402.1.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-08-30 Cont ID  
Sent By tlarge Date 2000-08-30 Time 11:29 Rev Time 1.75
Received By pschmitz Date 2000-08-28 Time 16:23 Sent To  
Notes
2001-01-08 00:00:001)SHT.A0-THE APPLICABLE PLUMBING CODE IS
 THE 1994 EDITION OF THE STANDARD PLUMB-
 ING CODE,NOT 1997.
  
 2)SHOW THE CLEAR INSIDE DIMENSIONS(LXW)
 OF THE HANDICAP TOILET STALLS.COMPLY W/
 FACBC SEC.4.17.3,FIG.30.
  
 3)THE GAS ISOMETRIC SHALL REFLECT THE
 FOLLOWING ITEMS.
 A)A COPY OF OR REFERENCE TO THE SPECIFIC
 GAS SIZING TABLE USED TO DESIGN THE
 SYSTEM.SGC 305.4
 B)SHOW DIMENSIONS OF ALL CUT SECTIONS OF
 PIPE,TYPE OF PIPING MATERIAL,ALL PIPE
 SIZES,TYPE OF GAS,ETC.
 C)DISTANCE TO MOST REMOTE OUTLET.
 D)DELIVERY PSI AT METER.
 E)CALCULATIONS FOR COMBUSTION AIR.
 F)TYPE,LOCATION AND SIZE OF GAS VENTS.
 G)MANUF.SHEETS FOR ALL GAS EQUIPMENT.
 (EQUIPMENT SHALL BE LISTED PER SGC SEC.
 402.1.)
  
 4)SUBMIT ADDITIONAL INFORMATION ON THE
 AIR INTAKE AND EXHAUST SYSTEMS FOR THE
 WATER HEATERS.(SEE SHT.P-3.)
  
 5)CONTROLS FOR GAS EQUIPMENT SHALL
 COMPLY W/ NFPA 5.5.4.,SGC 310.1.
 A MANUAL SHUT-OFF VALVE AND A UNION
 DOWNSTREAM SHALL BE INSTALLED AT
 CONTROLS FOR REMOVAL AND REPLACEMENT.
 VALVES SHALL BE LOCATED BELOW CEILING.
  
 6)WATER SUPPLY CONTROL SHALL COMPLY W/
 SPC SEC.610.4.2.(S.O.V.REQD.ON BRANCH
 MAIN).
  
 7)WASTES FROM THE BAR AREA SHALL DIS-
 CHARGE THROUGH THE GREASE INTERCEPTOR
 PER SPC 804.1,1004.4.
  
 8)CONTACT R.COMPO W/CITY OF WPB
 UTILITIES FOR CHANGES TO THE GREASY
 WASTE SYSTEM.(SUBMIT APPROVAL FROM
 UTILITIES FOR EXIST,GREASE TRAP.)
  
 9)A FLOOR SINK SHALL BE INSTALLED TO
 RECEIVE THE DISCHARGE FROM THE P & T
 VALVE
  
 10)A VACUUM RELIEF VALVE IS REQ,ON
 BOTTOM FED WATER HEATERS PER SPC SEC.
 507.1.2.
  
 11)SHT.P-4-NOT MORE THAN 2 FIXTURES CAN
 BE SUPPLIED BY 1/2"C.W.LINE.COUNTYWIDE
 AMENDMENTS TO SPC SEC.607.
  
 12)SHT.A8-MEN'S TOILET ROOM-H.C.STALL
 DOOR SWINGS INTO CLEAR FLOOR SPACE FOR
 LAV.COMPLY W/FACBC SEC.4.22.2.(SEE SHT.
 P2 ALSO).
  
 13)SHT.P4-THE APPLICABLE GAS CODE IS THE
 1997 EDITION OF THE STANDARD GAS CODE,
 NOT 1994.
  
 14)CLARIFY PSI FOR GAS SYSTEM.PLANS NOTE
 25 PSI?(SEE SHT.P4.)
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-05-27 Cont ID  
Sent By tlarge Date 2000-05-27 Time 08:01 Rev Time 1.75
Received By tlarge Date 2000-05-27 Time 08:01 Sent To  
Notes
2001-01-08 00:00:00PLANS SHALL BE ROUTED TO DEPT.OF
 BUSINESS REGULATION FOR REVIEW AND
 APPROVAL.COUNTYWIDE AMENDMENTS TO SPC
 SEC.101.4.7.
  
 SHT.A0-THE APPLICABLE PLUMBING CODE IS
 THE 1994 EDITION OF THE STANDARD
 PLUMBING CODE.
  
 SUBMIT SQ.FOOT AREA OF HABITABLE FLOOR
 SPACE FOR DETERMINATION OF MIN.FIXTURE
 REQS.SEE SPC SEC.407.1.3.FOR ALLOWED
 DEDUCTIBLE AREAS.
  
 SHOW DIMENSIONS OF HANDICAP STALLS.(LXW)
 COMPLY W/FACBC SEC.4.17.3.
  
 WALLS IN TOILET ROOMS SHALL BE
 NONABSORBENT TO A HEIGHT OF 4'PER SBC
 SEC.1204.2.
  
 STALL DOOR IN MEN'S TOILET ROOM SHALL
 NOT SWING INTO CLEAR FLOOR SPACE FOR
 LAVATORY.FACBC SEC.4.17.5,4.22.2(1).
  
 SUBMIT A COMPLETE GAS DRAWING SHOWING
 ALL GAS PIPING AS A WHOLE ALONG W/THE
 FOLLOWING ITEMS:
 A COPY OF OR REFERENCE TO THE SPECIFIC
 GAS SIZING TABLE USED TO DESIGN THE
 SYSTEM.
 2)SHOW DIMENSIONS OF ALL CUT SECTIONS OF
 PIPE,TYPE OF PIPING MATERIAL,ALL PIPE
 SIZES,TYPE OF GAS,ETC.
 3)DISTANCE TO MOST REMOTE OUTLET,
 4)DELIVERY PSI AT METER.
 5)CALCULATIONS FOR COMBUSTION AIR.
 6)TYPE,LOCATION AND SIZE OF GAS VENTS.+
 7)MANUF.SHEETS FOR ALL GAS EQUIP.
 (EQUIPMENT SHALL BE LISTED.SGC SEC.402.1
  
 SUBMIT MORE INFORMATION ON AIR INTAKE
 AND EXHAUST PIPING FOR WATER HEATERS.
 (SEE SHT.P-3)
  
 CONTROLS FOR GAS EQUIPMENT SHALL COMPLY
 W/NFPA 54 SEC.5.5.4.
  
 WATER SUPPLY CONTROL SHALL COMPLY W/SPC
 610.4.1,610.4.2.
  
 FLOOR SINKS SHALL BE USED IN KIT.AREA
 IN LIEU OF FLOOR RAINS PER SPC SEC.807.1
 807.1.3.
  
 INDIRECT WASTES SHALL COMPLY W/SPC SEC.
 805.1,805.2.
  
 WASTES FROM BAR SINK AREA SHALL DIS-
 CHARGE TO THE GREASE INTERCEPTOR PER SPC
 SEC.804.1,1004.4.
  
 CONTACT R.COMPO W/CITY OF WEST PALM
 BEACH UTILITIES FOR CHANGES TO THE
 GREASY WASTE SYSTEM.(SUBMIT APPROVAL
 FORM FROM UTILITIES FOR EXIST.GREASE
 INT.)

Review Stop Z ZONING
Rev No 1 Status N Date 2001-03-01 Cont ID  
Sent By lmartine Date 2001-03-01 Time 10:38 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***