| Plan Review Stops For Permit 00050907 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2001-01-26 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-01-25 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2001-01-25 |
Time |
11:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2001-01-12 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-01-12 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2000-11-09 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-11-09 |
Time |
10:10 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-11-09 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-09-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-09-28 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | BUILDING COMMENTS | | | ------------------- | | | | | | PLEASE REFER TO ORIGINAL COMMENTS | | | | | | 1] C0MMENTS 1THRU4 HAVE COMPLIED. | | | 2] COMMENT #5, DOOR SCHEDULE DOES NOT | | | REFLECT HOURLY RATINGS. | | | 3] COMMENT #6,7 AND 8 HAVE COMPLIED. | | | 4] COMMENT #9, SPRINKLER LAYOUT IN PATIO | | | STILL NOT PROVIDED. | | | | | | | | | | | | REVIEWED BY: | | | LUIS MARTINEZ | | | 561-659-8096 | | | EXT: #8456 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-06-28 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *****BUILDING REVIEW COMMENTS***** | | | | | | 1]SUBMIT PRODUCT TESTS FOR ANY NEW EXTER | | | IOR DOORS AND WINDOWS,PROVIDE IMPACT | | | PROTECTION METHOD FOR EXTERIOR GLAZING | | | 2]ENERGY CALCULATIONS ARE REQUIRED. | | | 3]SPECIFY ALL HAZARDOUS LOCATIONS FOR | | | GLAZING,SEE 2405.2,SBC. | | | 4]TABLE 1004,SBC,REQUIRES CORRIDOR AND | | | ISLE WIDTH TO BE MIN.44"CLEAR,FOR | | | OCCUPANCY OVER 50 PERSONS. | | | 5]CLERIFY [B] RATING FOR DOORS 121A AND | | | 121B,ALSO DOOR 121B SHALL PROVIDE 18" | | | CLEAR ON PULL SIDE OF HANDLE. | | | 6]PROVIDE ACCESSIBLE SEATING AT PATIO. | | | 7]SUBMIT EXITING CALCULATIONS FOR # OF | | | PERSONS EXITING FROM THE RESTAURANTS | | | AND THE BUILDING THRU THE VESTIBULE. | | | 8]HEALTH DEPARTMENT APPROVAL REQUIRED. | | | 9]SUBMIT FIRE SPRINKLER LAYOUT,PATIO | | | SEATING AREA MUST BE PROTECTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-09-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-19 |
Time |
20:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-19 |
Time |
20:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-06-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-05 |
Time |
20:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-05 |
Time |
20:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE SUBMIT THE AIC RATINGS | | | OF 600 AMP DISC AND 700AMP BREAKER. | | | MAINS MUST BE RATED FOR THE AVAILABLE | | | FAULT CURRENT.MUST BE PLANS 215-5 | | | | | | 2)NOTE: PLEASE NOTE AS PER LOCAL CODE | | | OUTLET SPACING TO BE EVERY 20` OF | | | UNENCUMBERED WALL SPACE. 210-50 SEE E-3 | | | CLOUDED AREA . | | | | | | 3)NOTE: PLEASE NOTE ART 450-21B FOR | | | TRANSFORMER ROOM REQ`MENTS. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 561-659-8096 EXT 8372 | | | | | | | | | PLEASE SHOW CHEFS PANEL LOCATION. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-06-19 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-06-19 |
Time |
09:49 |
Rev Time |
1.00 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | FIRE ALARM SYSTEM SHALL BE CLASS "A" OR | | | ADDRESSABLE. | | | | | | HOOD EXTINGUISHING SYSTEM SHALL BE | | | INTERCONNECTED WITH FIRE ALARM SYSTEM. | | | | | | INTERIOR FINISH SHALL BE CLASS A OR B. | | | | | | PROVIDE AN APPROVED,RATED CURTAIN IN THE | | | DOORWAY OF THE PRIVATE ROOM. CURTAIN | | | SHALL BE IN ACCORDANCE WITH NFPA 701. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-12-21 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-12-21 |
Time |
11:22 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-12-21 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO CHANGES TO PREVIOUSLY REVIEWED PLANS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-09-14 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-09-14 |
Time |
11:20 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-09-14 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-09 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-06-09 |
Time |
13:57 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-06-09 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***********DENIED********************** | | | 1) AIR CONDITIONING AND AIR BALANCE OK | | | | | | 2) PROVIDE DETAIL ON KITCHEN GREASE EX- | | | HAUST DUCT PATH OF TRAVEL FROM KITCHEN | | | TO OUTSIDE OF BUILDING | | | | | | 1997 SMC 505.9.1 VERTICAL AND HORIZONTAL | | | DUCTS LOCATED IN BUILDINGS TWO OR MORE | | | STORIES SHALL BE ENCLOSED IN A CONTIN- | | | UOUS ENCLOSURE FROM THE CEILING ABOVE | | | THE HOOD TO OR THROUGH THE ROOF. | | | SMC 505.9.2 REQUIRES THE ENCLOSURE TO BE | | | USED EXCLUSIVELY FOR A SINGLE GREASE | | | EXHAUST SYSTEM ANS SHALL BE USED FOR NO | | | OTHER PURPOSE. | | | NOTE: SEPARATE PERMITS REQUIRED FOR HOOD | | | WALK-IN COOLER/FREEZER AND FIRE SUPPRES- | | | SION FOR HOODS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2000-12-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-19 |
Time |
08:50 |
Rev Time |
1.50 |
| Received By |
jleech |
Date |
2000-12-19 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2000-11-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-15 |
Time |
12:16 |
Rev Time |
3.00 |
| Received By |
jleech |
Date |
2000-11-15 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1.STOP GAS RISER AT METER. DELETE GAS | | | SERVICE LINE AND COMMENT. | | | 2.TOTAL BTU'S TOTAL 1,389,000 3" PIPE | | | REQUIRED FROM METER TO FIRST DROP. | | | SHT. P-2 GAS PIPE SHOWN 3" ISO. SHOWS | | | 2 1/2" | | | 3.LIST GAS PIPE TYPE TO BE INSTALLED. | | | 4.SUBMIT MANUF. SHEETS FOR ALL GAS | | | EQUIPMENT. | | | 5.CALCULATIONS FOR COMBUSTION AIR | | | REQUIRED FOR WATER HEATERS. | | | 6.HANDYCAP STALLS DOES NOT COMPLY WITH | | | FACBC SEC 4.17.3 AND FIG. 30 | | | 7.CANNOT LOCATE DPR APPROVAL. | | | 8.W.H. VAC.BRACKER TO BE PIPED ABOVE | | | WATER HEATERS. | | | 9.WASTE FROM 3 COMPARTMENT SINK IN | | | BAR AREA TO BE PIPED TO GREASE INTER- | | | CEPTOR. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-09-15 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-15 |
Time |
18:30 |
Rev Time |
3.00 |
| Received By |
tlarge |
Date |
2000-09-15 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)SHT.A0-THE APPLICABLE PLUMBING CODE | | | IS THE 1994 EDITION OF THE STANDARD | | | PLUMBING CODE,NOT 1997. | | | | | | 2)SHOW THE CLEAR INSIDE DIMENSIONS(LXW) | | | OF THE HANDICAP STALLS.COMPLY W/FACBC | | | SEC.4.17.3,& FIG.30. | | | | | | 3)SUBMIT CALCULATIONS FOR COMBUSTION AIR | | | FOR THE WATER HEATERS.SGC SEC.402.4., | | | 402.4.4. | | | | | | 4)SUBMIT DETAIL OF GAS VENT.SHOW TYPE, | | | TERMINATION AND SIZE.SEE ATTACHED REQS. | | | SUBMIT DETAILS FOR THE AIR INTAKE AND | | | EXHAUST SYSTEMS FOR THE WATER HEATERS. | | | COMPLY W/SGC CHAPT.6.SEE SHT.P-3. | | | | | | 5)CONTROLS FOR GAS EQUIPMENT SHALL | | | COMPLY W/NFPA 5.5.4.,SGC SEC.310.1.A | | | MANUAL SHUT-OFF VALVE AND UNION SHALL BE | | | INSTALLED AT CONTROLS FOR REMOVAL AND | | | REPLACEMENT.VALVES SHALL BE LOCATED | | | BELOW CEILING. | | | | | | 6)WATER SUPPLY CONTROL SHALL COMPLY W/ | | | SPC SEC.610.4.2.(S.O.V.IS REQD.ON WATER | | | SUPPLY BRANCH FROM MAIN.) | | | | | | 7)CONTACT R.COMPO W/CITY OF WPB | | | UTILITIES FOR CHANGES TO THE GREASY | | | WASTE SYSTEM.(SUBMIT APPROVAL FROM | | | UTILITIES FOR GREASE TRAP.) | | | | | | 8)A FLOOR SINK IN LIEU OF THE FLOOR | | | DRAIN SHALL BE INSTALLED TO RECEIVE THE | | | DISCHARGE FROM THE P & T VALVE FROM THE | | | WATER HEATER.SPC SEC.804.1,807.1.3. | | | | | | 9)A VACUUM RELIEF VALVE IS REQD.ON | | | BOTTOM FED WATER HEATERS PER SPC.507.1.2 | | | | | | 10)SHT.P-4-NOT MORE THAN 2 FIXTURES | | | SHALL BE SUPPLIED BY 1/2" CW LINE. | | | COUNTYWIDE AMENDMENTS TO SPC SEC.607.7. | | | | | | 11)SHT.P-4-THE APPLICABLE GAS CODE IN | | | EFFECT IN THE CITY OF WPB IS THE 1997 | | | STANDARD GAS CODE,NOT HTE 1994 EDITION. | | | | | | 12)SHT.P-4-CLARIFY PSI FOR THE GAS | | | SYSTEM.PLANS NOTE 25 PS1.THIS CANNOT BE | | | CORRECT AS DESIGNED.COUNTYWIDE AMENDMENT | | | TO SPC SEC.104.2.1. | | | | | | 13)DISCHARGE OF EFFLUENT TO SANITARY | | | SYSTEM SHALL NOT EXCEED 140 DEGREES | | | UNLESS PROPER COOLING METHODS ARE | | | INCORPORATED.SPC SEC.717.8. | | | | | | 14.)DISHWASHER CANNOT DISCHARGE TO THE | | | GREASY WASTE SYSTEM PER LOCAL ORDINANCE. | | | DISCHARGE SHALL BE TO THE SANITARY | | | SYSTEM. | | | | | | 15)SHT.A-8-MEN'S TOILET ROOM-THE DOOR ON | | | THE HANDICAP STALL SHALL NOT SWING INTO | | | THE CLEAR FLOOR SPACE REQD.FOR THE LAV. | | | COMPLY W/FACBC SEC.4.22.2.(SEE SHT.P-2 | | | ALSO). | | | | | | 16)SIZE THE GAS LINES TO THE APPLIANCE. | | | COMPLY W/TABLE 305.4(A). | | | | | | 18)SUBMIT MANUF.SHEETS FOR GAS EQUIPMENT | | | EQUIPMENT SHALL BE LISTED PER SGC SEC. | | | 402.1. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-08-30 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-30 |
Time |
11:29 |
Rev Time |
1.75 |
| Received By |
pschmitz |
Date |
2000-08-28 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)SHT.A0-THE APPLICABLE PLUMBING CODE IS | | | THE 1994 EDITION OF THE STANDARD PLUMB- | | | ING CODE,NOT 1997. | | | | | | 2)SHOW THE CLEAR INSIDE DIMENSIONS(LXW) | | | OF THE HANDICAP TOILET STALLS.COMPLY W/ | | | FACBC SEC.4.17.3,FIG.30. | | | | | | 3)THE GAS ISOMETRIC SHALL REFLECT THE | | | FOLLOWING ITEMS. | | | A)A COPY OF OR REFERENCE TO THE SPECIFIC | | | GAS SIZING TABLE USED TO DESIGN THE | | | SYSTEM.SGC 305.4 | | | B)SHOW DIMENSIONS OF ALL CUT SECTIONS OF | | | PIPE,TYPE OF PIPING MATERIAL,ALL PIPE | | | SIZES,TYPE OF GAS,ETC. | | | C)DISTANCE TO MOST REMOTE OUTLET. | | | D)DELIVERY PSI AT METER. | | | E)CALCULATIONS FOR COMBUSTION AIR. | | | F)TYPE,LOCATION AND SIZE OF GAS VENTS. | | | G)MANUF.SHEETS FOR ALL GAS EQUIPMENT. | | | (EQUIPMENT SHALL BE LISTED PER SGC SEC. | | | 402.1.) | | | | | | 4)SUBMIT ADDITIONAL INFORMATION ON THE | | | AIR INTAKE AND EXHAUST SYSTEMS FOR THE | | | WATER HEATERS.(SEE SHT.P-3.) | | | | | | 5)CONTROLS FOR GAS EQUIPMENT SHALL | | | COMPLY W/ NFPA 5.5.4.,SGC 310.1. | | | A MANUAL SHUT-OFF VALVE AND A UNION | | | DOWNSTREAM SHALL BE INSTALLED AT | | | CONTROLS FOR REMOVAL AND REPLACEMENT. | | | VALVES SHALL BE LOCATED BELOW CEILING. | | | | | | 6)WATER SUPPLY CONTROL SHALL COMPLY W/ | | | SPC SEC.610.4.2.(S.O.V.REQD.ON BRANCH | | | MAIN). | | | | | | 7)WASTES FROM THE BAR AREA SHALL DIS- | | | CHARGE THROUGH THE GREASE INTERCEPTOR | | | PER SPC 804.1,1004.4. | | | | | | 8)CONTACT R.COMPO W/CITY OF WPB | | | UTILITIES FOR CHANGES TO THE GREASY | | | WASTE SYSTEM.(SUBMIT APPROVAL FROM | | | UTILITIES FOR EXIST,GREASE TRAP.) | | | | | | 9)A FLOOR SINK SHALL BE INSTALLED TO | | | RECEIVE THE DISCHARGE FROM THE P & T | | | VALVE | | | | | | 10)A VACUUM RELIEF VALVE IS REQ,ON | | | BOTTOM FED WATER HEATERS PER SPC SEC. | | | 507.1.2. | | | | | | 11)SHT.P-4-NOT MORE THAN 2 FIXTURES CAN | | | BE SUPPLIED BY 1/2"C.W.LINE.COUNTYWIDE | | | AMENDMENTS TO SPC SEC.607. | | | | | | 12)SHT.A8-MEN'S TOILET ROOM-H.C.STALL | | | DOOR SWINGS INTO CLEAR FLOOR SPACE FOR | | | LAV.COMPLY W/FACBC SEC.4.22.2.(SEE SHT. | | | P2 ALSO). | | | | | | 13)SHT.P4-THE APPLICABLE GAS CODE IS THE | | | 1997 EDITION OF THE STANDARD GAS CODE, | | | NOT 1994. | | | | | | 14)CLARIFY PSI FOR GAS SYSTEM.PLANS NOTE | | | 25 PSI?(SEE SHT.P4.) | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-05-27 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-05-27 |
Time |
08:01 |
Rev Time |
1.75 |
| Received By |
tlarge |
Date |
2000-05-27 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLANS SHALL BE ROUTED TO DEPT.OF | | | BUSINESS REGULATION FOR REVIEW AND | | | APPROVAL.COUNTYWIDE AMENDMENTS TO SPC | | | SEC.101.4.7. | | | | | | SHT.A0-THE APPLICABLE PLUMBING CODE IS | | | THE 1994 EDITION OF THE STANDARD | | | PLUMBING CODE. | | | | | | SUBMIT SQ.FOOT AREA OF HABITABLE FLOOR | | | SPACE FOR DETERMINATION OF MIN.FIXTURE | | | REQS.SEE SPC SEC.407.1.3.FOR ALLOWED | | | DEDUCTIBLE AREAS. | | | | | | SHOW DIMENSIONS OF HANDICAP STALLS.(LXW) | | | COMPLY W/FACBC SEC.4.17.3. | | | | | | WALLS IN TOILET ROOMS SHALL BE | | | NONABSORBENT TO A HEIGHT OF 4'PER SBC | | | SEC.1204.2. | | | | | | STALL DOOR IN MEN'S TOILET ROOM SHALL | | | NOT SWING INTO CLEAR FLOOR SPACE FOR | | | LAVATORY.FACBC SEC.4.17.5,4.22.2(1). | | | | | | SUBMIT A COMPLETE GAS DRAWING SHOWING | | | ALL GAS PIPING AS A WHOLE ALONG W/THE | | | FOLLOWING ITEMS: | | | A COPY OF OR REFERENCE TO THE SPECIFIC | | | GAS SIZING TABLE USED TO DESIGN THE | | | SYSTEM. | | | 2)SHOW DIMENSIONS OF ALL CUT SECTIONS OF | | | PIPE,TYPE OF PIPING MATERIAL,ALL PIPE | | | SIZES,TYPE OF GAS,ETC. | | | 3)DISTANCE TO MOST REMOTE OUTLET, | | | 4)DELIVERY PSI AT METER. | | | 5)CALCULATIONS FOR COMBUSTION AIR. | | | 6)TYPE,LOCATION AND SIZE OF GAS VENTS.+ | | | 7)MANUF.SHEETS FOR ALL GAS EQUIP. | | | (EQUIPMENT SHALL BE LISTED.SGC SEC.402.1 | | | | | | SUBMIT MORE INFORMATION ON AIR INTAKE | | | AND EXHAUST PIPING FOR WATER HEATERS. | | | (SEE SHT.P-3) | | | | | | CONTROLS FOR GAS EQUIPMENT SHALL COMPLY | | | W/NFPA 54 SEC.5.5.4. | | | | | | WATER SUPPLY CONTROL SHALL COMPLY W/SPC | | | 610.4.1,610.4.2. | | | | | | FLOOR SINKS SHALL BE USED IN KIT.AREA | | | IN LIEU OF FLOOR RAINS PER SPC SEC.807.1 | | | 807.1.3. | | | | | | INDIRECT WASTES SHALL COMPLY W/SPC SEC. | | | 805.1,805.2. | | | | | | WASTES FROM BAR SINK AREA SHALL DIS- | | | CHARGE TO THE GREASE INTERCEPTOR PER SPC | | | SEC.804.1,1004.4. | | | | | | CONTACT R.COMPO W/CITY OF WEST PALM | | | BEACH UTILITIES FOR CHANGES TO THE | | | GREASY WASTE SYSTEM.(SUBMIT APPROVAL | | | FORM FROM UTILITIES FOR EXIST.GREASE | | | INT.) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-03-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-03-01 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|