| Plan Review Stops For Permit 00050833 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-08-02 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-08-02 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-16 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-06-16 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2000-06-12 |
Time |
09:38 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-05 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-12-05 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-07-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-27 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-27 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-05-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-30 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-30 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SUBMIT LOAD CALCULATION | | | SHOWING DETAIL/BREAKDOWN OF CALCS. | | | YOU HAVE NOTE ON PLAN FOR CONTINUOUS | | | LOADS? PLEASE SHOW IT IN THE CALCULATION | | | FOR ALL CONTINUOUS LOADS. (LIGHTING ETC) | | | | | | 2)NOTE: PLEASE NOTE THAT THE MDP NEEDS | | | TO CORRELATE WITH THE LOADS SHOWN ON | | | PANELS. PLEASE MATCH UP. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. PLANS WOULD HAVE PASSED WITH A | | | PROVISO, BUT WERE COMING BACK FOR PLUMB | | | COMMENTS. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2000-08-18 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-08-18 |
Time |
13:43 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PASSED |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2000-08-09 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-08-09 |
Time |
15:04 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | FAILED | | | TOO MANY COMMENTS MUST BE ADDRESSED | | | 1- 6" GRAVITY SEWER LATERALS REQUIRED ON | | | CITY ROW.4" IS ALLOWED ON PRIVATE | | | PROPERTY. | | | 2- SHOW SIZES OF EXISTING DIP WM AS BEIN | | | G 6" AND PLACE NOTE TO BE FIELD VERIFIED | | | 3- PLACE METER ON SIDEWALK | | | 4- PLEASE SHOW FULL EXTENT OF ALL SANITA | | | RY LINES AND WATER LINE UP TO THE BUILDI | | | NG. MEASURE AND SEE IF ANY DEP PERMITS | | | WILL BE REQUIRED. | | | 5-CORRECT DIRECT TAP NOTE TO REFLECT | | | EXISTING PIPE SIZE THAT YOU WILL BE | | | CONNECTING TO. | | | 6- SDR 26 PVC IS THE MINIMUM REQUIREMENT | | | FOR SANITARY SEWER SERVICES OUT IN R.O.W | | | 7- PROVIDE ON PLAN THE SUNSHINE LOCATING | | | NOTE 1 800 432 4770 | | | 8- PLEASE PROVIDE ON PLAN THE PERVIOUS | | | AND IMPERVIOUS INFORMATION IN ACRES AND | | | IN SQUARE FEET. | | | 9- SHOW POLLUTION CONTROL FENCE AROUND | | | CONSTRUCTION SITE AND POLLUTION CONTROL | | | DEVICES. | | | 10- THE 6" STUB MUST BE INSTALLED AFTER | | | DDCV. (SEE PLAN) | | | AFTER PLAN HAS BEEN SUBMITTED PLEASE | | | FILL THE PRODUCT SUBMITTAL LIST AND | | | RETURN TWO COPIES ONE FOR OUR INSPECTOR | | | AND ON FOR THE FILE. | | | ANY QUESTIONS MAY BE DIRECTED TO MANNY | | | GONZALEZ AT PUBLIC UTILITIES | | | 1000 45TH STR WPB FL 33407 | | | 561 659 8040 PLEASE RETURN MARK-UP | | | ALONG WITH THE TWO NEW REVISED SETS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2000-06-05 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-06-05 |
Time |
14:33 |
Rev Time |
3.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVIDE WATER AND SEWER PLAN SHOWING | | | THE FOLLOWING ITEMS: | | | CONNECTIONS OF WATER SERVICE WILL BE | | | THRU DIRECT TAPS ONLY. PROVIDE SIZE | | | (NO TAPPING SADDLES WILL BE ALLOWED) | | | SHOW EXIST. METER LOCATION AND NOTE | | | METER TO BE SHUT OFF, CUT AND PLUGGED. | | | | | | NEW METER LOCATION MUST BE JUST OUT SIDE | | | OF RIGHT OF WAY ON THE SIDEWALK WITH | | | LOCKING METER BOX LID AND TOUCH READ | | | HOLE.THE DOUBLE CHECK DETECTOR ASSEMBL | | | Y MUST JUST INSIDE PROPERTY LINE/R.O.W. | | | LINE. | | | | | | SHOW EXISTING WATER AND SEWER LINE | | | LOCATIONS ALONG SAQUOIA DRIVE. | | | FOR LOCATION OF THESE LINE YOU MAY | | | CONTACT OUR CAD DEPARTMENT AT 659-8040 | | | EXT. 2303 | | | FOR SEWER CONNECTION YOU MAY CONNECT TO | | | EXISTING SANITARY SEWER SERVICE LINE IF | | | IT IS 6" OR HIGHER, THIS WOULD COST | | | EFFECTIVE TO THE PROPERTY OWNER. | | | | | | AN 18" MINIMUM SEPARATION IS REQUIRED | | | BETWEEN ALL WATER AND SEWER. | | | | | | A 6" MINIMUM SEPERATION WILL BE REQUIRED | | | BETWEEN SANITARY AND STORM. | | | | | | WHEN CONNECTION NEW SEWER SERVICE TO | | | NEW PARISH HALL THE BATHROOMS CONNECTION | | | S MUST BE CONNECTED AFTER THE GREASE | | | TRAP.A CLEAN OUT WILL BE REQUIRED AT | | | EVERY TURN OR EVER 100 L.F. OF STRAIGHT | | | RUN. A CLEAN OUT IS REQUIRED JUST INSIDE | | | OF PROPERTY LINE. | | | NO STORM PLAN HAS BEEN SUBMITTED. | | | SEE ATTACHED OUR STORM WATER UTILITY | | | REQUIREMENTS. | | | | | | SINCE THERE IS A MINIMAL AMOUNT OF STORM | | | YOU MAY INCLUDE IT IN WATER AND SEWER | | | PLAN. | | | | | | YOU MUST ALSO PROVIDE THE CITY'S | | | STANDARD DETAILS THAT MAY APPLY. EITHER | | | CREATE A NEW SHEET OR YOU MAY INCLUDE | | | THEM ON THIS SHEET IF THEY FIT. | | | | | | ONCE PLANS HAVE BEEN APPROVED THE | | | CONTRACTOR MUST SUPPLY SHOP DRAWINGS | | | FOR APPROVAL BY CITY OF WEST PALM BEACH | | | PUBLIC UTILITIES ENGINEERING DEPARTMENT | | | ATTENTION MANNY GONZALEZ, PROJECT SPECIA | | | LIST. LOCATION: 1000 45TH ST. SUITE 9 | | | WEST PALM BEACH, FL 33407 (561) 659-8040 | | | EXT. 2306 | | | | | | ALL PAVEMENT CUT TO INSTALL SERVICES | | | MUST BE NOTED AND REFERENCED TO THE | | | OUR STANDARD PAVEMENT REPLACEMENT DETAIL | | | | | | THE WATER SEWER AND DRAINAGE MUST BE | | | DESIGNED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED CIVIL ENGINEER. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-12-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-12-10 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-12-10 |
Time |
14:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-07-18 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-07-18 |
Time |
09:57 |
Rev Time |
0.25 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-07-18 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-06-06 |
Time |
14:06 |
Rev Time |
1.00 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | | | | 1.FIRE ALARM SYSTEM SHALL BE CLASS "A" | | | OR ADDRESSABLE.PROVIDE SPEAKER STROBES | | | IN EACH SECOND FLOOR MEETING ROOM. | | | 2.KITCHEN HOOD EXTINGUISHING SYSTEM | | | SHALL BE CONNECTED TO THE FIRE ALARM | | | SYSTEM. | | | 4. INTERIOR FINISH SHALL THROUGHOUT | | | SHALL BE CLASS A OR B. | | | 5.PROVIDE PANIC HARDWARE ON ALL | | | DESIGNATED EXIT DOORS SUBJECT TO 100 OR | | | MORE PERSONS.(PARISH HALL,NORTH & SOUTH | | | EXIT CORRIDORS,&DOORS LEADING TO STAIRS) | | | 6. DOORS 36 AND 37 SHALL SWING IN THE | | | DIRECTION OF EXIT TRAVEL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2001-12-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-08 |
Time |
11:54 |
Rev Time |
1.30 |
| Received By |
pkrauss |
Date |
2001-12-08 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-08-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-08-07 |
Time |
15:43 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-08-07 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-07-24 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-24 |
Time |
09:01 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-24 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-09 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-06-09 |
Time |
13:11 |
Rev Time |
2.00 |
| Received By |
ndenmark |
Date |
2000-06-09 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************DENIED******************** | | | 1) EXHAUST FAN #7 SERVES FIRST FLOOR | | | SPACE, INTERLOCKED WITH SECOND FLOOR | | | EQUIPMENT. INTERLOCK TO EQUIPMENT WHICH | | | SERVES FLOOR INVOLVED. | | | 2) EQUIPMENT UNIT DATA CONFLICTS WITH | | | VOLUME OF AIR DELIVED TO SPACE. CORRECT | | | TO REFLECT EQUIPMENT MATCHING SPACE | | | REQUIREMENTS | | | 3) AIR CONDITIONING UNIT DATA SHOWS | | | UNIT #5 AND #6. THESE UNITS ARE NOT | | | INDICATED ON PLAN. WHAT AREAS DO THESE | | | SERVE? | | | 4) PROVIDE AIR BALANCE SCHEDULE TO SHOW | | | COMPLIANCE WITH 1997 SMC 501.2 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2000-08-11 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-11 |
Time |
10:58 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
2000-08-11 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *****************PROVISO**************** | | | | | | 1)DETAILS AND CALCULATIONS SHALL BE | | | SUBMITTED FOR SECONDARY ROOF DRAINAGE | | | SYSTEM.COMPLY W/SPC SECX.1109.1-1109.3 | | | AND APPENDIX"A".INCLUDE 1/2 THE AREA OF | | | THE PARAPET WALL PER SPC SEC.1108.3. | | | SHOW THE CALCULATIONS PER THE ABOVE | | | NOTED CODE SECTIONS AND SIZE THE | | | SCUPPERS ACCORDINGLY.THE SCUPPERS FOR | | | THE HIGH ROOF ARE DRAINING ONTO THE LOW | | | ROOF.WHERE IS THE SECONDARY DRAINAGE | | | FOR THE LOW ROOF?PROVIDE CALCULATIONS | | | THAT THE 2-4" ROOF DRAINS WILL HANDLE | | | THE ADDITIONAL LOAD.PLANS SHALL BE | | | SUBMITTED FOR REVIEW WITHIN 7 DAYS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-08-10 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-10 |
Time |
19:58 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
2000-08-10 |
Time |
19:58 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | AS PREVIOUSLY REQUESTED-SUBMIT DETAILS | | | AND CALCULATIONS FOR SECONDDARY ROOF | | | DRAINAGE SYSTEM.COMPLY W/SPC SEC.1109.1- | | | 1109.3 AND APPENDIX "A".INCLUDE 1/2 THE | | | AREA OF THE PARAPET WALL PER SPC 1108.3. | | | SHOW THE CALCULATIONS PER THE ABOVE | | | NOTED CODE SECTIONS AND SIZE THE | | | SCUPPERS ACCORDINGLY.THE SCUPPERS ARE | | | SHOWN DRAINING ONTO THE LOW ROOF.WHERE | | | IS THE SECONDARY SYSTEM FOR THIS AREA & | | | PROVIDE CALCULATIONS THAT THE 2-4"ROOF | | | DRAINS WILL HANDLE THE ADDITIONAL LOAD. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-08-04 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-04 |
Time |
17:16 |
Rev Time |
3.00 |
| Received By |
tlarge |
Date |
2000-08-04 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)LAVATORIES ARE REQD.IN THE HANDICAP | | | STALLS ON THE 2ND.LEVEL.FACBC SEC.4.17.3 | | | | | | 2)SHOW THE LENGTH AND WIDTH OF THE | | | HANDICAP STALLS ON THE FIRST AND SECOND | | | LEVELS.COMPLY W/FACBC SEC.4.17.3.AND | | | FIG.30.(MIN.WIDTH SHALL NOT BE LESS THAN | | | 83".) | | | | | | 3)SUBMIT DETAILS AND CALCULATIONS FOR | | | SECONDARY ROOF DRAINAGE SYSTEM.COMPLY W/ | | | SPC SEC.1109.1-1109.3.AND APPENDIX "A". | | | | | | 4)SUBMIT DETAIL OF GREASE TRAP.COMPLY | | | W/CITY OF WPB REQS.(SEE ATTACHED). | | | SUBMIT APPROVAL FORM FROM CITY OF WPB | | | UTILITIES.CONTACT R.COMPO AT 561-835- | | | 7423. | | | | | | 5)WATER CLOSETS NOT PERMITTED ON WET | | | VENTS PER COUNTYWIDE AMENDMENTS TO SPC | | | SEC.911.1.1. | | | | | | 6)CLEANOUTS IN BLDG.SEWER SHALL BE | | | SPACED PER SPC 710.2.4. | | | | | | 7)DRINKING FOUNTAIN SHALL COMPLY W/FACBC | | | SEC.4.1.3.(10)(A).PROVISIONS SHALL BE | | | MADE FOR PEOPLE WHO HAVE TROUBLE BENDING | | | OR STOOPING. | | | | | | IF YOU HAVE ANY QUESTIONS CALL | | | 561-659-8096,EXT.8377. | | | | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-05-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-05-26 |
Time |
19:07 |
Rev Time |
1.00 |
| Received By |
tlarge |
Date |
2000-05-26 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT DETAILS ON THE TYPES OF FUNCTIONS | | | AND ACTIVITIES TAKING PLACE IN THE | | | STRUCTURE.COUNTYWIDE AMENDMENTS TO SPC | | | SEC.104.2.1. | | | | | | LAVATORIES ARE REQD.WITHIN THE H.C. | | | ACCESSIBLE STALLS PER FACBC SEC.4.17.3. | | | | | | SIZE OF ACCESSIBLE STALLS SHALL COMPLY | | | W/FACBC SEC.4.17.3. | | | | | | A H.C.ACCESSIBLE STALL IS REQD.IN EACH | | | TOILET ROOM PER FACBC 4.1.3.(11). | | | (UNISEX TOILET ROOM WILL NOT SUFFICE) | | | | | | TOILET ROOMS SHALL HAVE WAINSCOTING UP | | | TO 4' PER SBC SEC.1204.2. | | | | | | SHT.ME-2-SHOWS 6"ROOF DRAIN LINE | | | DRAINING INTO 4"LINE.COMPLY W/SPC 307.5, | | | 709.1,709.2. | | | | | | SUBMIT COMPLETE STORM DRAINAGE ISOMETRIC | | | SHOWING SQ.FT.AREA OF ROOF DRAINED BY | | | EACH DRAIN AND PROVISIONS FOR SECONDARY | | | (EMERGENCY )DRAINAGE. | | | | | | SHT.P1-WATER SERVICE AND SEWER CANNOT BE | | | RUN IN THE SAME TRENCH PER SPC 307.5. | | | | | | CONTACT CITY OF WEST PALM BEACH UTILITY | | | DEPT.FOR GREASE TRAP APPROVAL.SUBMIT | | | COPY OF APPROVAL FORM.CONTACT R.COMPO | | | AT 835-7423. | | | | | | DISHWASHER SHALL DISCHARGE TO SANITARY | | | PER CITY OF WPB ORDINANCE. | | | | | | PVC INSTALLED ON ROOF SHALL BE SUPPORTED | | | AT 4' INTERVALS PER SPC SEC.310.3.6. | | | | | | SHT.P4-2ND.FLR.SANITARY-DRY VENTS NOT | | | PERMITTED PER SPC 906.2.1. | | | | | | WATER CLOSET NOT PERMITTED ON WET VENT | | | PER COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 911.1.1. | | | | | | A PERMIT MAY BE REQD.FROM DEPT.OF | | | ENVIRONMENTAL PROTECTION FOR THE WATER | | | AND SEWER LINES. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-06-22 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-06-16 |
Time |
14:11 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|