Plan Review Details - Permit 00050295
Plan Review Stops For Permit 00050295
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2000-06-20 Cont ID  
Sent By bstaples Date 2000-06-15 Time 14:48 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-01-08 00:00:00LETTER FROM SPECIAL INSPECTOR IS A FAX
 ORIGIONAL REQUIRED.
 PASSED BILL STAPLES SEE APP

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2000-06-06 Cont ID  
Sent By bstaples Date 2000-06-06 Time 07:46 Rev Time 2.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00SECOND REVIEW 6/6/00
 1. ITEMS 1, 2, 3, 4, FROM REVIEW OF
 5/4/00 NOT ADDRESSED. PLEASE PROVIDE
 INFORMATION REQUESTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-05-09 Cont ID  
Sent By bstaples Date 2000-05-09 Time 12:57 Rev Time 2.50
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:005/9/00 PLANS DENIED, SEE FOLLOWING
  
 1. LETTER FROM SPECIAL INSPECTOR
 RELEASING THE SPACE FOR CONSTRUCTION.
 2. FLORIDA ENERGY SHEETS OK 6/15/00
 3. FIRE SPRINKLER APPREC 6/15/00MIT
 4. EXTERIOR GLAZING TO MEET 1997 SBC FOR
 IMPACT PROTEOK REC 6/15/00 LOADS.
 5. SHEET A5.1 EIFS SHALL MEET THE
 REQUIREMENTS OF 1997 SBC CHAPTER 26 AND
 PROVIDE PRODUCT APPROVAL INFORMATION.
 6. SIGNS REQUIRE SEPERATE PERMITS.
 7. SHEET 10.1 REVISE LOCATION ADDRESS TO
 PROPER NUMBER A11 IS NOT APPROVED.
 8. SHEET A2.1 SECTION 3 ON A6.3 SHOULD
 BE A WALL SECTION DRAWING IS A CELING
 DETAIL?
 9. SHEET A2.1 SECTION 3 ON A6.5 SHOULD
 BE A WALL SECTION DETAIL IS FOR A CARPET
 TO WOOD SITUATION?
 SHEET A2.1 SECTION 7 ON A6.5 SHOULD BE A
 STRUCTURAL SECTION FOR A NEW DOOR DETAIL
 IS FOR THE DOOR THRESHOLD?
 10. SHEET A6.1 DETAIL J SECTION 1 ON
 A-6.2 FOR FIRE SEPERATION IS A CROSS
 BRACING DETAIL?
 11. PLAN REVIEW STOPPED, REVIEW ALL
 DRAWING AND RE SUBMIT AFTER COORDINATION
 OF CONSTRUCTION DETAILS.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-10-18 Cont ID  
Sent By dpalmer Date 2000-10-18 Time 21:33 Rev Time 0.00
Received By dpalmer Date 2000-10-18 Time 21:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-06-05 Cont ID  
Sent By dpalmer Date 2000-06-05 Time 16:51 Rev Time 0.00
Received By dpalmer Date 2000-06-05 Time 15:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-05-09 Cont ID  
Sent By dpalmer Date 2000-05-09 Time 21:16 Rev Time 0.00
Received By dpalmer Date 2000-05-09 Time 21:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-05-15 Cont ID  
Sent By bstaples Date 2000-05-15 Time 11:18 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00SEE PROVISO M. CARSILLO 5/9/00

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-05-19 Cont ID  
Sent By cthirben Date 2000-05-19 Time 13:27 Rev Time 2.00
Received By cthirben Date 2000-05-19 Time 13:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-06-04 Cont ID  
Sent By tlarge Date 2000-06-04 Time 08:24 Rev Time 0.65
Received By tlarge Date 2000-06-04 Time 08:24 Sent To  
Notes
2001-01-08 00:00:00*****************PROVISO****************
 ACCESSIBLE DRESSING ROOM SHALL COMPLY W/
 FACBC SEC.4.35.4 THE BENCH SHALL MEASURE
 24"X 48"AND BE MOUNTED 17"-19"AFF.THE
 BENCH SHALL BE FIXED TO THE WALL ALONG
 THE LONGER DIMENSION.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-05-16 Cont ID  
Sent By tlarge Date 2000-05-16 Time 19:39 Rev Time 0.75
Received By tlarge Date 2000-05-16 Time 19:39 Sent To  
Notes
2001-01-08 00:00:00PROVISO:DRESSING ROOM SHALL COMPLY W/
 FACBC SEC.4.35.