| Plan Review Stops For Permit 00050265 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-07-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-18 |
Time |
19:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-18 |
Time |
19:54 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************** PROVISO ************* | | | | | | 1)NOTE :PLEASE SUBMIT REVISED PLANS | | | FOR REVIEW WITH ALL INKED IN CHANGES | | | MADE TO PLANS OF RECORD. | | | | | | 2)NOTE : PLEASE INCLUDE THE BATH(S) | | | CIRCUIT(S) AS PER 210-11-C-3 AND AS | | | PREVIOUS NOTES ASKED FOR. PLEASE LIST ON | | | PANEL SCHEDULE. | | | | | | PLEASE SUBMIT FOR REVIEW BEFORE FINAL | | | ELECTRICAL INSPECTION IS CALLED IN. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-05-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-31 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-31 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SUBMIT LOAD CALCULATION | | | FOR NEW LOAD AND EXISTING LOADS REQ`D BY | | | 220-3-C-1 PLEASE SHOW EXISTING SERVICE | | | SIZE. RISER DIAGRAM. | | | | | | 2))NOTE: PLEASE NOTE THAT SMOKE DETECTOR | | | -S ARE REQ`D INSIDE AND OUTSIDE ALL | | | SLEEPING ROOMS IN NEW DWELLINGS/ AREAS. | | | NFPA-72 2-2.1.1.1 | | | | | | 3)NOTE:PLEASE LIST ON THE PANEL SCHEDULE | | | THE REQ`D DEDICATED BATH(S) CIRCUIT(S) | | | PER 210-11-C-3 MUST BE 20AMP #12 AWG. | | | | | | 4)NOTE: PLEASE SEE MISSING OUTLET PER | | | 210-52 2` OF WALL. | | | | | | 5)NOTE:PLEASE LABEL ALL GFI RECEPTS IN | | | GARAGE AS BEING GFI/GFI PROTRECTED AS | | | REQ`D BY 210-8/215-5 | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW.IF THERE ARE ANY QUESTIONS | | | PLEASECALL 659-8096 EXY 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-07-18 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-18 |
Time |
17:42 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-18 |
Time |
17:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-03 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-06-03 |
Time |
07:22 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-06-03 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************DENIED****************** | | | REQUIRE MORE INFORMATION ON A/C UNIT, | | | THE MODEL #, SIZE, UNIT CAPABLE OF | | | HANDLING THE ADDITIONAL LOAD REQUIRMENTS | | | ETC. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-07-11 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-11 |
Time |
07:14 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-07-11 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT SANITARY AND WATER RISER PRIOR TO | | | PLUMBING INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-06-03 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-03 |
Time |
05:59 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-06-03 |
Time |
05:59 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT SIGNED AND SEALED SANITARY AND | | | WATER RISER DIAGRAMS FOR REVIEW.COUNTY- | | | WIDE AMENDMENTS TO SPC SEC.104.2.1. | | | | | | COMPILE SHEETS INTO TWO COMPLETE SETS OF | | | PLANS.COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 104.2.1. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2001-06-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-06-12 |
Time |
18:39 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2001-06-12 |
Time |
18:39 |
Sent To |
|
|
| Notes |
| 2001-06-12 00:00:00 | TRUSS DRAWINGS REVIEW. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2001-05-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-05-22 |
Time |
17:29 |
Rev Time |
0.75 |
| Received By |
jgomez |
Date |
2001-05-22 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2001-05-22 00:00:00 | TRUSS DRAWINGS SECOND CHECKLIST: | | | | | | 1-TRUSS LAYOUT AND ENGINEERED TRUSSES: | | | A)WHO IS THE ENGINEER RESPONSIBLE FOR | | | THE LAYOUT? MISSING INFORMATION AS | | | REQUIRED BY CHAPTER 471 FL. STATUTES. | | | (NO DONE FROM PREVIOUS CHECKLIST). | | | | | | B)WHY IS THERE ANOTHER ENGINEER SIGNING | | | AND SEALING THE ENGINEERED TRUSSES? | | | C)WHY IS THERE ANOTHER ENGINEER SIGNING | | | AND SEALING THE PARALLAM BEAM? | | | D)WHERE IS TRUSS FGA ON TRUSS LAYOUT? | | | E)ENGINEER TO PROVIDE ORIGINAL | | | SIGNATURE ON TRUSS FGA AS REQUIRED BY | | | CHAPTER 471 OF FLORIDA STATUTES. | | | F)UPDATE DESIGN CRITERIA ON TRUSS | | | LAYOUT AS REQUIRED: ASCE 7-95 145MPH | | | (NO DONE FROM PREVIOUS CHECKLIST). | | | | | | 2-ARCHITECT TO REVIEW ALL TRUSS DRAWINGS | | | PRIOR TO SUBMITTAL TO THIS OFFICE. | | | -USE STANDARD REVIEW STAMP TO IDENTIFY | | | REVIEWED DRAWINGS. | | | | | | 3-ARCHITECT TO PROVIDE A COMPLETE ANCHOR | | | SCHEDULE THAT IS CLEARLY KEYED TO THE | | | FRAMING PLANS.INFORMATION SUBMITTED | | | IS VERY CONFUSING AND IS NOT CLEAR | | | WHERE IT APPLIES TO. | | | | | | | | | NOTE: INFORMATION SUBMITTED IS VERY | | | CONFUSING & RAISES MORE QUESTIONS | | | THAN ANSWERS. IF YOU HAVE ANY | | | QUESTIONS CONCERNING MY COMMENTS, | | | PLEASE CALL JULIO GOMEZ AT | | | 659-8096 EXT. 8232. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2001-05-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-05-07 |
Time |
17:34 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2001-05-07 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2001-05-07 00:00:00 | TRUSS DRAWINGS CHECKLIST: | | | 1-WHO IS THE ENGINEER FOR THE TRUSS | | | DRAWINGS? IT IS MISSING ALL THE | | | INFORMATION REQUIRED BY CHAPTER 471 OF | | | FLORIDA STATUTES. | | | 2-PROVIDE TWO COPIES OF THE ENGINEERED | | | TRUSSES USING ASCE 7-95 FOR 145 MPH | | | (NOT ASCE FOR 110 MPH AS SHOWN ON | | | TRUSS LAYOUT). | | | 3-ARCHITECT OF RECORD TO REVIEW ALL | | | TRUSS DRAWINGS PRIOR TO SUBMITTAL TO | | | THIS OFFICE. | | | 4-ARCHITECT TO PROVIDE A COMPLETE ANCHOR | | | SCHEDULE SPECIFYING CONNECTORS TO | | | RESIST CALCULATED LOADS ON ENGINEERED | | | DRAWINGS. | | | 5-UPDATE TRUSS LAYOUT DESIGN CRITERIA. | | | SEE COMMENTS ON LAYOUT. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-07-27 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-07-27 |
Time |
11:33 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | OK PER T. MAURCELLO | | | PRODUCT APPROVAL NEEDED FOR ROOF COVER | | | OR UNDER SEPARATE PERMIT. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-06-13 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2000-06-13 |
Time |
11:03 |
Rev Time |
0.10 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PER TONY MARCELLO6/12/00 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-05-08 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-05-08 |
Time |
10:43 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|