Plan Review Details - Permit 00050265
Plan Review Stops For Permit 00050265
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-07-18 Cont ID  
Sent By dpalmer Date 2000-07-18 Time 19:54 Rev Time 0.00
Received By dpalmer Date 2000-07-18 Time 19:54 Sent To  
Notes
2001-01-08 00:00:00****************** PROVISO *************
  
 1)NOTE :PLEASE SUBMIT REVISED PLANS
 FOR REVIEW WITH ALL INKED IN CHANGES
 MADE TO PLANS OF RECORD.
  
 2)NOTE : PLEASE INCLUDE THE BATH(S)
 CIRCUIT(S) AS PER 210-11-C-3 AND AS
 PREVIOUS NOTES ASKED FOR. PLEASE LIST ON
 PANEL SCHEDULE.
  
 PLEASE SUBMIT FOR REVIEW BEFORE FINAL
 ELECTRICAL INSPECTION IS CALLED IN.
 IF THERE ARE ANY QUESTIONS PLEASE CALL
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-05-31 Cont ID  
Sent By dpalmer Date 2000-05-31 Time 15:11 Rev Time 0.00
Received By dpalmer Date 2000-05-31 Time 15:11 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLEASE SUBMIT LOAD CALCULATION
 FOR NEW LOAD AND EXISTING LOADS REQ`D BY
 220-3-C-1 PLEASE SHOW EXISTING SERVICE
 SIZE. RISER DIAGRAM.
  
 2))NOTE: PLEASE NOTE THAT SMOKE DETECTOR
 -S ARE REQ`D INSIDE AND OUTSIDE ALL
 SLEEPING ROOMS IN NEW DWELLINGS/ AREAS.
 NFPA-72 2-2.1.1.1
  
 3)NOTE:PLEASE LIST ON THE PANEL SCHEDULE
 THE REQ`D DEDICATED BATH(S) CIRCUIT(S)
 PER 210-11-C-3 MUST BE 20AMP #12 AWG.
  
 4)NOTE: PLEASE SEE MISSING OUTLET PER
 210-52 2` OF WALL.
  
 5)NOTE:PLEASE LABEL ALL GFI RECEPTS IN
 GARAGE AS BEING GFI/GFI PROTRECTED AS
 REQ`D BY 210-8/215-5
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW.IF THERE ARE ANY QUESTIONS
 PLEASECALL 659-8096 EXY 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-07-18 Cont ID  
Sent By cthirben Date 2000-07-18 Time 17:42 Rev Time 1.00
Received By cthirben Date 2000-07-18 Time 17:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-06-03 Cont ID  
Sent By cthirben Date 2000-06-03 Time 07:22 Rev Time 1.00
Received By cthirben Date 2000-06-03 Time 07:22 Sent To  
Notes
2001-01-08 00:00:00****************DENIED******************
 REQUIRE MORE INFORMATION ON A/C UNIT,
 THE MODEL #, SIZE, UNIT CAPABLE OF
 HANDLING THE ADDITIONAL LOAD REQUIRMENTS
 ETC.

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-07-11 Cont ID  
Sent By tlarge Date 2000-07-11 Time 07:14 Rev Time 0.50
Received By tlarge Date 2000-07-11 Time 07:14 Sent To  
Notes
2001-01-08 00:00:00SUBMIT SANITARY AND WATER RISER PRIOR TO
 PLUMBING INSPECTION.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-06-03 Cont ID  
Sent By tlarge Date 2000-06-03 Time 05:59 Rev Time 0.33
Received By tlarge Date 2000-06-03 Time 05:59 Sent To  
Notes
2001-01-08 00:00:00SUBMIT SIGNED AND SEALED SANITARY AND
 WATER RISER DIAGRAMS FOR REVIEW.COUNTY-
 WIDE AMENDMENTS TO SPC SEC.104.2.1.
  
 COMPILE SHEETS INTO TWO COMPLETE SETS OF
 PLANS.COUNTYWIDE AMENDMENTS TO SPC SEC.
 104.2.1.

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2001-06-12 Cont ID  
Sent By jgomez Date 2001-06-12 Time 18:39 Rev Time 0.50
Received By jgomez Date 2001-06-12 Time 18:39 Sent To  
Notes
2001-06-12 00:00:00TRUSS DRAWINGS REVIEW.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2001-05-22 Cont ID  
Sent By jgomez Date 2001-05-22 Time 17:29 Rev Time 0.75
Received By jgomez Date 2001-05-22 Time 17:29 Sent To  
Notes
2001-05-22 00:00:00TRUSS DRAWINGS SECOND CHECKLIST:
  
 1-TRUSS LAYOUT AND ENGINEERED TRUSSES:
 A)WHO IS THE ENGINEER RESPONSIBLE FOR
 THE LAYOUT? MISSING INFORMATION AS
 REQUIRED BY CHAPTER 471 FL. STATUTES.
 (NO DONE FROM PREVIOUS CHECKLIST).
  
 B)WHY IS THERE ANOTHER ENGINEER SIGNING
 AND SEALING THE ENGINEERED TRUSSES?
 C)WHY IS THERE ANOTHER ENGINEER SIGNING
 AND SEALING THE PARALLAM BEAM?
 D)WHERE IS TRUSS FGA ON TRUSS LAYOUT?
 E)ENGINEER TO PROVIDE ORIGINAL
 SIGNATURE ON TRUSS FGA AS REQUIRED BY
 CHAPTER 471 OF FLORIDA STATUTES.
 F)UPDATE DESIGN CRITERIA ON TRUSS
 LAYOUT AS REQUIRED: ASCE 7-95 145MPH
 (NO DONE FROM PREVIOUS CHECKLIST).
  
 2-ARCHITECT TO REVIEW ALL TRUSS DRAWINGS
 PRIOR TO SUBMITTAL TO THIS OFFICE.
 -USE STANDARD REVIEW STAMP TO IDENTIFY
 REVIEWED DRAWINGS.
  
 3-ARCHITECT TO PROVIDE A COMPLETE ANCHOR
 SCHEDULE THAT IS CLEARLY KEYED TO THE
 FRAMING PLANS.INFORMATION SUBMITTED
 IS VERY CONFUSING AND IS NOT CLEAR
 WHERE IT APPLIES TO.
  
  
 NOTE: INFORMATION SUBMITTED IS VERY
 CONFUSING & RAISES MORE QUESTIONS
 THAN ANSWERS. IF YOU HAVE ANY
 QUESTIONS CONCERNING MY COMMENTS,
 PLEASE CALL JULIO GOMEZ AT
 659-8096 EXT. 8232.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-05-07 Cont ID  
Sent By jgomez Date 2001-05-07 Time 17:34 Rev Time 1.00
Received By jgomez Date 2001-05-07 Time 17:34 Sent To  
Notes
2001-05-07 00:00:00TRUSS DRAWINGS CHECKLIST:
 1-WHO IS THE ENGINEER FOR THE TRUSS
 DRAWINGS? IT IS MISSING ALL THE
 INFORMATION REQUIRED BY CHAPTER 471 OF
 FLORIDA STATUTES.
 2-PROVIDE TWO COPIES OF THE ENGINEERED
 TRUSSES USING ASCE 7-95 FOR 145 MPH
 (NOT ASCE FOR 110 MPH AS SHOWN ON
 TRUSS LAYOUT).
 3-ARCHITECT OF RECORD TO REVIEW ALL
 TRUSS DRAWINGS PRIOR TO SUBMITTAL TO
 THIS OFFICE.
 4-ARCHITECT TO PROVIDE A COMPLETE ANCHOR
 SCHEDULE SPECIFYING CONNECTORS TO
 RESIST CALCULATED LOADS ON ENGINEERED
 DRAWINGS.
 5-UPDATE TRUSS LAYOUT DESIGN CRITERIA.
 SEE COMMENTS ON LAYOUT.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-07-27 Cont ID  
Sent By fknapp Date 2000-07-27 Time 11:33 Rev Time 2.00
Received By fknapp Date   Time   Sent To  
Notes
2001-01-08 00:00:00OK PER T. MAURCELLO
 PRODUCT APPROVAL NEEDED FOR ROOF COVER
 OR UNDER SEPARATE PERMIT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-06-13 Cont ID  
Sent By lsmith Date 2000-06-13 Time 11:03 Rev Time 0.10
Received By lsmith Date   Time   Sent To  
Notes
2001-01-08 00:00:00PER TONY MARCELLO6/12/00

Review Stop Z ZONING
Rev No 1 Status P Date 2000-05-08 Cont ID  
Sent By gjoyce Date 2000-05-08 Time 10:43 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***