| Plan Review Stops For Permit 00050235 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2000-10-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-10-24 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-10-24 |
Time |
14:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2000-10-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-10-10 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-10-10 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE NOTES FROM FIRST TWO | | | REVIEWS. | | | | | | 2)NOTE: PLEASE SEE PANELS "B" AND "C" | | | STILL SHOW (3) AIR HANDLER UNIT #1. | | | ALSO WIRE SIZED AT 10AWG W/ 50A, 10KW | | | LOAD.? | | | | | | 3)NOTE: PLEASE SEE BRKR FEED TO PANEL | | | "C". SHOWN AT 2P30? 1/0 CONDUCTOR SIZE.? | | | | | | 4)NOTE: PLEASE NOTE THAT AIC RATINGS FOR | | | PANELS HAVE NOT BEEN SUBMITTED. | | | PER110-9 AND 215-5 | | | | | | 5)NOTE: PANEL SCHEDULES FOR PANEL "A" | | | SHOWS MLO?? WHERES MAIN? | | | S | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-09-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-11 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-11 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | | | | | | 1)NOTE: PLEASE NOTE THAT ALL THE NOTES | | | ON THE FIRST REVIEW WERE NOT ADDRESSED. | | | PLEASE SEE THE LIST ATTACHED AND MAKE | | | CORRECTIONS. | | | | | | 2)NOTE: PLEASE SEE PLANS AND SHOW WHERE | | | PANEL "C" IS BEING FED FROM.?? | | | PLEASE SHOW CONDUIT/WIRE/BRKR/ ETC. | | | | | | PLEASE SUBMIT ALL THE INFORMATION FROM | | | BOTH REVIEWS. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 659-8096 EXT8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2000-10-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-30 |
Time |
21:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-30 |
Time |
21:46 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** PROVISO *************** | | | | | | 1)NOTE: PLEASE SUBMIT THE AIC RATING OF | | | THE EQUIPMENT MAINS. MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT AS REQ`D BY | | | 110-9 AND 215-5. | | | | | | 2)NOTE; PLEASE NOTE THAT ON THE PANEL | | | SCHEDULES YOU ARE SHOWING GAS WATER | | | HEATER AND GAS DRYER AND YET YOU ARE | | | SHOWING A HIGH ELECTRIC LOAD. ?? PLEASE | | | CALRIFY.IF GAS PLEASE CORRECT LOAD. | | | | | | 3) NOTE: PLEASE NOTE AS REQ`D BY 210-11- | | | -C-3 . PLEASE LIST THE REQ`D DEDICATED | | | BATH(S) CIRCUIT(S) . MUST BE 20 AMP AND | | | #12 AWG. | | | | | | 4)NOTE: PLEASE CORRECT LOAD SHOWN FOR | | | ELECTRIC COOK TOP? 2000VA 2P50? | | | | | | 5)NOTE: YOU SHOW TWO AHU-1 PLEASE CORREC | | | -T. AND NOTE THAT YOU ARE SHOWING 10000W | | | ON #10 AWG.2P50. | | | | | | 6)NOTE:MISSING OUTLET SECOND FLOOR 2`OF | | | WALL 210-52 | | | | | | 7)NOTE: PLEASE NOTE SD MISSING SD OUT- | | | -SIDE BEDROOM. UPSTAIRS AND NEED TO | | | MOVE SD DOWNSTAIRS TO BE IN THE VICINITY | | | OF STAIRS. NFPA-72 2-2.1.1.1 | | | | | | 8)NOTE:PLEASE INCLUDE AND SHOW THE COLD | | | WATER PIPE AND BLDG.STEEL AS PART OF THE | | | GROUNDING ELECTRODE SYSTEM AND SHOW ON | | | RISER DIAGRAM. 250-50 /215-5 | | | | | | 9)NOTE:PLEASE LABEL AND SHOW ALL OUTLETS | | | SERVING KITCHEN COUNTERSPACE AS GFI/GFI | | | PROTECTED AS REQ`D BY 210-8-A-6. | | | | | | 10)NOTE: PLEASE NOTE MISSING OUTLET REQ` | | | FOR COUNTER OUTLET SPACING PER 210-52- | | | C-1. | | | | | | 11)NOTE:MISSING SMOKE DETECTOR OUTSIDE | | | BEDROOM DOWNSTAIRS. | | | | | | 12)NOTE: MISSING MEANS OF EGRESS LIGHT- | | | -ING OUTSIDE GARAGE DOOR. 210-70 | | | | | | 13)NOTE:MISSING GFI REC FOR A/C CU`S | | | | | | 14)NOTE: PLEASE SHOW PANEL LOCATIONS ON | | | FLOOR PLAN., 215-5 | | | | | | 15)NOTE:MISSING OUTLETS FOR 2` OF WALL | | | FOYER/DEN | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW BEFORE ROUGH/ELEC FOR SLAB. | | | THIS INFORMATION MUST BE PROVIDED. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-09-13 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-09-13 |
Time |
09:27 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-09-13 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-05-15 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-05-15 |
Time |
08:04 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-05-15 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************PROVISO***************** | | | NOTES: INDICATE ON PLANS. | | | 1. CFM'S VALUE OF EXHAUST FANS | | | 2. DRYER VENT SIZE AND LOCATION | | | 3. RETURN AIR FOR AHU # 1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2001-09-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-09-05 |
Time |
16:39 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2001-09-05 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-08-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-08-23 |
Time |
16:23 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2001-08-23 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-09-08 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-08 |
Time |
09:27 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-09-08 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *******************PROVISO************** | | | SEPARATE PERMIT REQD.FOR GAS. | | | | | | SUBMIT CALCULATIONS FOR COMBUSTION AIR | | | FOR DRYER.SGC SEC.402.4. | | | | | | WATER HEATER IN GARAGE SHALL COMPLY W/ | | | SGC 402.7. | | | | | | SUBMIT REVISED SANITARY RISER PRIOR TO | | | PLBG.INSPECTION.COUNTYWIDE AMENDMENTS TO | | | SPC SEC.104.2.1. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-05-08 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-05-08 |
Time |
08:12 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-05-08 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2000-10-20 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-10-20 |
Time |
10:33 |
Rev Time |
3.00 |
| Received By |
fknapp |
Date |
2000-10-20 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | *************BUILDING PROVISO*********** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR: | | | ARCH WINDOWS | | | OCTAGON WINDOWS | | | | | | PLEASE SUBMIT PRIOR TO INSTALLATION. | | | | | | 2)PROVIDE STORM PANEL INFORMATION UNDER | | | SEPARATE PERMIT. | | | | | | 3)PROVIDE ENGINEER REPORTS AND APPROVAL | | | OF PILE INSTALLATION PRIOR TO CONCRETE | | | SLAB BEING POURED. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2000-10-13 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-10-13 |
Time |
11:42 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2000-10-13 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ************BUILDING UNSAT************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR: | | | INSWING DOOR WITH SIDELITES | | | ARCH TRANSOMS | | | OCTAGON WINDOWS | | | MULLIONS | | | | | | 2)PROVIDE INSTALLATION SCHEDULE AND | | | KEY PLAN FOR STORM PANELS. | | | | | | 3)PROVIDE OWNER/AGENT SIGNATURE ON | | | ENERGY CALCULATIONS. | | | | | | 4)PROVIDE FRAMING DETAILS FOR DECORATIVE | | | CHIMNEY. | | | | | | 5)PROVIDE ENGINEER REPORTS AND APPROVAL | | | OF PILE INSTALLATION PRIOR TO CONCRETE | | | BEING POURED. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-09-07 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-09-07 |
Time |
11:46 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-09-07 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | | | | **********BUILDING UNSAT**************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR: | | | INSWING DOOR WITH SIDELITES | | | FIX GLASS | | | ARCH TRANSOMS | | | OCTAGON WINDOWS | | | MULLIONS AND ROOF COVERING | | | | | | 2)PROVIDE INSTALLATION SCHEDULE AND KEY | | | PLAN WITH SPECIFIC ANCHORS TO BE USE | | | FOR STORM PANELS. | | | | | | 3)PROVIDE ENERGY CALCULATIONS WITH | | | MANUEL J FORM. | | | | | | 4)PROVIDE SOIL TEST. | | | | | | 5)PROVIDE SHEET A-2 FOR BOTH SETS OF | | | PLANS. | | | | | | 6)SPECIFY USE OF CHIMNEY, NO FIRE PLACE | | | SHOWM ON PLANS. | | | | | | 7)PROVIDE ENGINEER REPORTS AND APPROVAL | | | OF PILE INSTALLATION PRIOR TO CONCRETE | | | BEING POURED. | | | | | | 8)PROVIDE FLOOD ZONE ELEVATION | | | CERTIFICATE WITH FLOOR ELEVATION AT 7'5" | | | OR BETTER. | | | | | | 9)NEED ZONNING APPROVAL. | | | | | | 10)BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO., THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-05-04 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-05-04 |
Time |
14:25 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | MUST GET CONCURRENY FROM TIM |
|
|