| Plan Review Stops For Permit 00050062 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2001-02-09 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-02-09 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-02-09 00:00:00 | SHUTTERS DENIED | | | 1.A SEPARATE PERMIT IS REQUIRED FOR | | | THE INSTALLATION OF THE SHUTTERS SINCE | | | THE INFORMATION WAS NOT INCLUDED WITH | | | THE ORIGINAL BUILDING PERMIT | | | APPLICATION. | | | | | | 2.SELECT WHICH COMPONENTS WILL BE | | | USED FROM THE REPORT. | | | | | | 3.PROVIDE A SKETCH OF THE BLDG AND | | | OPENINGS TO BE COVERED WITH DIMENSIONS. | | | | | | 4.REVIEW THE FASTENER LIMITATIONS IN | | | THE PRODUCT REPORT. | | | | | | HAROLD PISKURA | | | 659-8096 X 8219 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2000-08-23 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-08-23 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2000-08-15 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-08-15 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | LETTER W/ PERMIT APP HHP |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-07-31 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-07-31 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-20 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-06-20 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-07-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-20 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-20 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************PROVISO**************** | | | | | | 1)NOTE: PLEASE CORRECT LOAD CALCUALTIONS | | | TO SHOW ALL CONTINUOUS LOADS AT 125% | | | LIGHTING ETC. PER 220 OF THE NEC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW BEFORE FINAL ELECTRICAL INSPEC- | | | -TION IS CALLED IN. IF THERE ARE ANY | | | QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELETRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH. | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-05-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-09 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-09 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE ART 210-62 OF THE NEC | | | AS TO THE REQ`MENTS FOR SHOW WINDOW | | | OUTLETS. | | | | | | 2)NOTE:YOU ARE SHOWINGEXISTING BUILD. | | | SERVICE BEINGREFED BY SERVICE ON NEW | | | BUILD. THE EXISTING BUILDING MUST BE | | | PART OF THE NEW BUILDING.THIS MEANS | | | STRUCTUALLY ATTACHED AND BY ZONING | | | APPROVAL. IF THIS IS THE CASE THEN | | | PLEASE HAVE SERVICE CLEARLY LABELED AS | | | TO WHAT THE MAINS DISCONNECTS. | | | | | | 3)NOTE: PLEASE SUBMIT ALL AIC RATINGS | | | OF MAINS AND PANELS. PER 110-9 AND 215-5 | | | MAINS MUST BE RATED FOR THE AVAILABLE | | | FAULT CURRENT. | | | | | | 4)NOTE:ALL LOAD CALCUALTIONS NEED TO | | | SHOW ALL CONTINUOUS LOADS FIGURED AT | | | 125%. PLEASE SHOW.LIGHTING ETC. | | | | | | 5)NOTE: PANEL SCHEDULE/OR PLANS DO NOT | | | SHOW THE REQ`D ROOFTOP RECEPT. REQ`D BY | | | 210-63 PLEASE SHOW | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2000-07-17 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-07-17 |
Time |
10:34 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ALL ENGINEERING COMMENTS HAVE | | | BEEN REVIEWED AND APPROVED. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2000-05-24 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-05-24 |
Time |
13:54 |
Rev Time |
2.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NEED POLLUTION CONTROL PLAN | | | | | | PROVIDE HANDI CAP ACCES TO SIDEWALK | | | EITHER BY PROVIDING A FLUSH SIDEWALK | | | WITH CAR STOPS ON PARKING ALONG FRONT | | | OF BUILDING OR PROVIDE HANDI CAP RAMPS | | | | | | A HANDI CAP RAMP IS REQUIRED ON THE | | | NORTH SIDE OF PARKING TO SIDEWALK THAT | | | CONNECTS TO 45TH ST PEDESTRIAN ACCESS. | | | | | | DUMPSTER DETAIL NEEDS REVISION TO | | | A 12'-6" OPENING MINIMUM TO ALLOW DUMP- | | | STER AND A 13'-8" DEPTH IS REQUIRED. | | | | | | NOTE: WATER AND SEWER SERVICES ARE NOT | | | LOCATED ON ANY OF THESE PLANS. IF ANY | | | RELOCATIONS, WATER AND SEWER MUST BE | | | APPROVED BY CITY OF WEST PALM BEACH | | | PUBLIC UTILITIES DEPARTMENT | | | 1000 45TH STREET, WPB, FL 33405 | | | ATTENTION: MANNY GONZALEZ 561 659 8040 | | | EXT. 2306 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-05-03 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-05-03 |
Time |
11:41 |
Rev Time |
0.35 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-05-04 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-05-04 |
Time |
08:13 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-05-04 |
Time |
08:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2000-08-21 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-21 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
tlarge |
Date |
2000-08-21 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ENTERED IN ERROR |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-07-20 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-07-20 |
Time |
10:28 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-05-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-05-06 |
Time |
11:33 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PLAN REVIEW PES | | | (1) SHT A-2 HANDI CAP STALL TO COMPLY | | | WITH FACBC 97 SEC 4.17.3 EXCEPTION | | | ( NEW CONSTRUCTION ) WIDTH OF STALL. | | | (2)SHT A-2 ALL DEMINISONS FOR HANDI CAP | | | TO COMPLY WITH FACBC-97. | | | (4) SHT A-4 URI MISS LABLED AS BIDETS. | | | END OF COMMENTS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2000-07-12 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-07-12 |
Time |
11:20 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2000-06-19 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-05-02 |
Time |
10:41 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | HAS NOT RESPONDED TO PPRC COMMENTS | | | BUILDINGS CAN NOT CONNECT |
|
|