| Plan Review Stops For Permit 00050057 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2001-03-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-03-09 |
Time |
06:44 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-09 00:00:00 | APPROVE WD-65 BY FOLD DOORS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2001-02-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-02-22 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-02-21 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-02-21 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-02-21 00:00:00 | REVISION DATED 1/24/01 HOOOD PLATFORM. | | | NEEDS DOWN TOWN REVIEW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-08-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-08-01 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***PROVISO*** | | | | | | 1]SUBMIT CORRECTED ENERGY EFFICIENCY | | | CALCULATIONS. | | | 2]IF STORM SHUTTERS ARE PROPOSED FOR | | | IMPACT PROTECTION,PLEASE SUBMIT TEST | | | REPORT WITH ENGINEERING FOR APPROVAL. | | | ALSO SUBMIT INSTALLATION AND STORAGE | | | PLAN. | | | | | | | | | REVIEWED BY: | | | LUIS MARTINEZ | | | 561-659-8096#8456 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-20 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-06-20 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***PLAN REVIEW COMMENTS*** | | | | | | 1]SIGNED AND SEALED SURVEYS ARE REQUIRED | | | 2]PROVIDE CITY'S APPROVAL FOR CONSTR. | | | ON CITY PROPERTY. | | | 3]SUBMIT TEST REPORTS FOR ALL INTERIOR | | | FINISHES MUST COMPLY WITH 803,'97SBC. | | | 4]PROVIDE TEST REPORTS FOR WIND AND | | | IMPACT COMPLIANCE ON ALL EXTERIOR DOOR | | | AND WINDOW SYSTEMS. | | | 5]DOORS #24 AND 25 MUST BE APPROVED TYPE | | | DOORS,SEE 1012SBC. | | | 6]DOORS #6,20,25,AND26 MUST BE 20 MIN. | | | RATED IF PART OF THE EXIT ACCESS. | | | 7]DOORS 15 AND 16 MUST COMPLY WITH '97 | | | FAC,4.13.6[MANUVERING CLEARENCES FROM | | | PULL SIDE]. | | | 8]ENTRY CANOPY'S SHALL COMPLY WITH APPEN | | | "F",102.2.8 | | | 9]TYPE 2 CONSTRUCTION REQUIRES ANY WOOD | | | USED,SHALL BE OF FIRE RETARDANT TREAT- | | | ED. | | | 10]SPECIFY WHICH CODE WAS USED FOR THE | | | DESIGN CALCULATION,EACH PAGE SHALL BE | | | SIGNED AND SEALED. | | | 11]SUBMIT ENERGY EFFICIENCY CALCULATIONS | | | 12]PROVIDE ACCESSIBLE SEATING FOR DINING | | | PATIO"C". | | | 13]SUBMIT FIRE SPRINKLER LAYOUT. | | | | | | REVIEWED BY | | | LUIS MARTINEZ | | | 561-659-8096#8456 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2001-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-01 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-01 |
Time |
18:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2001-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-27 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-27 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2001-02-27 00:00:00 | ******************* UNSAT ************ | | | | | | 1)NOTE: PLEASE NOTE THAT UNDER F.A.C. | | | SECTION(S) 481.221 AND 471.025 ALL CHANG | | | ES ON PLANS ARE TO BE DONE BY THE ARCH/ | | | ENGINEER OF RECORD. PLANS ARE TO BE | | | SEALED/ SIGNED AND DATED. | | | | | | PLEASE REDRAW AND SUBMIT THE ABOVE INFOR | | | MATION FOR REVIEW. IF THERE ARE ANY | | | QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2001-02-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-22 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-22 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2001-02-22 00:00:00 | ****************** UNSAT ************ | | | | | | 1)NOTE: PLEASE SUBMIT SIGNED AND SEALED | | | PLANS PER F.A.C SECT 481.221. | | | | | | 2)NOTE: PLEASE PROVIDE INFORMATION ON | | | LOCATIONS OF TRANSFORMERS. | | | | | | 3)NOTE: PLEASE SHOW ALL BRANCH CIRCUIT | | | #`S ON PLANS THAT CORRELATE WITH PANEL | | | SCHEDULE. | | | | | | 4)NOTE: PLEASE PROVIDE INFORMATION ON | | | THE CONTROL OF ALL FIXTURES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-08-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2000-08-02 |
Time |
12:45 |
Rev Time |
1.45 |
| Received By |
jleahy |
Date |
2000-08-02 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | TRANSFORMER TO MEET 450-21BJLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-07-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-27 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-27 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT***************** | | | | | | 1)NOTE: UNSAT FOR PHASE TWO (II) | | | PLEASE SEE AND ADDRESS FIRST SET OF | | | NOTES GIVEN BY JAKE LEAHY. | | | | | | 2)NOTE: PLEASE PROVIDE CONDUIT LAYOUT | | | PLAN, SHOWING CONDUIT SIZES FOR PHASE | | | I ONLY. | | | | | | 3)NOTE: PLEASE SUBMIT SPECS ON 1400 AMP | | | OCP SHOWN AT 1600AMP MAIN. 1400 AMP | | | FUSES ARE NOT STANDARD AND IF YOU HAVE | | | A MANUFACTURE`S LISTING, THEN PLEASE | | | SUBMIT. SEE ART;240-6 | | | | | | | | | IF WIRE SIZES, AND CONDUIT SIZES CHANGE | | | DUE TO MAIN OCP THEN THERE WOULD BE A | | | PROBLEM ISSUING ANY PERMIT FOR PHASE I | | | ELECTRICAL. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-05-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2000-05-25 |
Time |
13:09 |
Rev Time |
1.30 |
| Received By |
jleahy |
Date |
2000-05-25 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1-PG. E-5 MAIN FEEDER TO MDP IS TOO SMAL | | | WIRE HAS TO MATCH BREAKER AND BE BASED | | | ON 75C RATING NOT 90C 110-14(C2) | | | | | | 2-PG. E-5 GROUNDING ELECTRODE CONDUCTOR | | | IS TOO SMALL SHOULD BE A LEAST A 4/0 | | | 250-66 | | | | | | 3-PG. E-5 NO AIC RATINGS SHOWN FOR ANY | | | PANELS, MAINS, BREAKERS, OR OTHER EQUP | | | 110-9,10 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2000-08-14 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-08-14 |
Time |
14:20 |
Rev Time |
2.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PASSED WITH PROVISOS | | | 1. ANY WORK ALONG SIDEWALK MUST BE | | | CONTAINED ON SITE.ANY DAMAGE TO EXIST. | | | SIDEWALK MUST BE RESTORE TO EQUAL OR | | | BETTER CONDITIONS. | | | 2. DUMPSTER MUST BE ACCESSIBLE AT ALL | | | TIMES. SEE DUMPSTER MINIMUM DIMENSIONS | | | ON DETAIL ATTACHED. | | | 3. PROVIDE TWO COPIES OF PLANS SHOWING | | | WATER, SEWER AND DRAINAGE FOR PUBLIC | | | UTILITIES APPROVAL. | | | ATTENTION: MANNY GONZALEZ | | | PROJECT SPECIALIST | | | 1000 45TH ST, SUITE 15 | | | WEST PALM BEACH, FL 33407 | | | 561-659-8040 FAX 561-659-8039. | | | PLEASE ALSO SUBMIT SHOP DRAWINGS | | | TO THE SAME LOCATION.WE MUST RETAIN | | | TWO COPIES, 1 FOR THE UTILITY FILE AND | | | 1 FOR OUR PUBLIC UTILITY INSPECTORS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-03-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-03-05 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-03-05 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-01-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-01-26 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-01-26 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2001-01-26 00:00:00 | 1) DEEP FAT FRYERS ARE TO BE EQUIPPED | | | WITH HIGH LIMIT CONTROLS. | | | 2) IT APPEARS THAT MORE CLEAN-OUTS MAY | | | BE NEEDED TO PROPERLY INSPECT AND CLEAN | | | THE EXHAUST DUCTS. | | | | | | APPROVED PROVISO: | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-08-04 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-08-04 |
Time |
14:46 |
Rev Time |
1.00 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVIDE PANICK HARDWARE ON ALL DESIGNATE | | | D EXIT DOORS. | | | PROVIDE SHOP DRAWINGS FOR HOOD AND | | | EXTINGUISHING SYSTEM. | | | PROVIDE SHOP DRAWINGS FOR FIRE ALARM | | | SYSTEM. | | | SUBMIT SEATING DIAGRAM TO THE FIRE DEPT. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-05-09 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-05-09 |
Time |
15:02 |
Rev Time |
0.55 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVIDE FIRE SPRINKLER DRAWINGS. | | | PROVIDE PANICK HARDWARE ON ALL EXIT | | | DOORS. | | | PROVIDE SHOP DRAWINGS FOR HOOD | | | EXTINGUISHING SYSTEM, FIRE ALARM SYSTEM | | | AND FIRE SPRINKLER SYSTEM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-08-16 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-08-16 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
cthirben |
Date |
2000-08-16 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | *FAN SHUTDOWN FOR A SYSTEM UNDER | | | 2000 CFM SERVING AN AREA USED AS AN | | | EGRESS AS PER 1997 SMC 406.2.... | | | *ADDITIONAL PERMIT REQUIRED FOR HOOD, | | | FIRE SUPPRESSION SYSTEM, FUEL AND WALK- | | | IN COOLER/FREEZER. | | | | | | ***EXHAUST DUCT INSIDE RATED SHAFT SHALL | | | MAINTAIN A MINIMUM CLEARANCE OF 6" AS | | | PER 1997 SMC 505.9.1 AND NOT AS STATED | | | ON SHEET M7 OF THE PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-05-24 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-05-24 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
cthirben |
Date |
2000-05-24 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ******************PROVISO*************** | | | 1. FAN SHUTDOWN FOR AGGREGATE AREA OF | | | 2000 CFM OR MORE, OR UNDER 2000 CFM | | | BUT SERVING AN AREA USED FOR EGRESS | | | 1997 SMC 406.2 | | | 2. ADDITIONAL PERMIT REQUIRED FOR HOOD, | | | FIRE SUPPRESSIONAND GAS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2001-01-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-18 |
Time |
17:07 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2001-01-18 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2001-01-18 00:00:00 | GAS REVISIONS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2000-08-15 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-15 |
Time |
17:21 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
2000-08-15 |
Time |
17:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-08-14 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-14 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2000-08-14 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-08-01 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-01 |
Time |
18:26 |
Rev Time |
3.00 |
| Received By |
pschmitz |
Date |
2000-08-01 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)INDICATE TYPE OF PIPING FOR GAS SYSTEM | | | TO ENSURE COMPLIANCE W/SGC.(JOB SPECS. | | | ARE NOT WITH PLANS.) | | | | | | 2)SHT.A2.0-RESTROOM FIXTURE CALCULATIONS | | | ARE NOT IN COMPLIANCE W/SPC TABLE 407 | | | FOR THE TYPE OF OCCUPANCIES AND OCCUPANT | | | LOAD.RESTAURANT LOAD TO BE BASED ON | | | NUMBER OF SEATS NOTED ON SHEET A5.1. | | | (154)AN ADDITIONAL WATER CLOSET IS REQD. | | | IN EACH TOILET ROOM. | | | | | | 3)ADDITIONAL INFORMATION REQD.FOR POWER | | | VENT FOR GAS WATER HEATER.SEE SHT.M1, | | | NOTE #4. | | | | | | 4)SHT.M1-SUBMITTED COMBUSTION AIR CALC- | | | ULATIONS ARE DEFICIENT AS DESIGNED. | | | COMPLY W/SGC SEC.402.4.4.4(3),NFPA 5.3.5 | | | | | | 5)SHT.M2-KIT.EQUIP.#P-11A SHALL | | | DISCHARGE TO GREASY WASTE.SPC 1004.4. | | | | | | 6)DISHWASHER SHALL DISCHARGE TO THE | | | SANITARY SYSTEM PER CITY OF WPB ORDIN- | | | ANCE. | | | | | | 7)COMBINATION WASTE AND VENT SYSTEM IS | | | NOT SIZED TO SPC SEC.921.4.1-921.4.2. | | | SYSTEM SHALL DISCHARGE TO THE GREASY | | | WASTE SYSTEM,NOT THE SANITARY.SPC SEC. | | | 1004.4. | | | | | | 8)SUBMIT APPROVAL FORM FROM CITY OF WPB | | | UTILITIES DEPT.FOR GREASE TRAP.COUNTY | | | WIDE AMENDMENTS TO SPC SEC.101.4.7. | | | CONTACT R.COMPO AT 561-835-7423. | | | | | | 9)WATER SUPPLY CONTROL SHALL COMPLY W/ | | | SPC SEC.610.4.1.,610.4.2. | | | | | | 10)DISPOSAL OF CONDENSATE SHALL COMPLY | | | W/SMC SEC.304.8.3.(SEE SHT.M3,COL.A6) | | | | | | 11)DRESSING ROOM BENCH SHALL BE LOCATED | | | ALONG THE LONGER DIMENSION WALL PER | | | FACBC SEC.4.35.4. | | | | | | 12)URINALS SHALL BE SCREENED FOR PRIVACY | | | PER SPC SEC.404.3. | | | | | | 13)SEE ATTACHED DRAWING FOR GREASE TRAP. | | | | | | IF YOU HAVE ANY QUESTIONS I CAN BE | | | REACHED AT 561-659-8096,EXT.8377. | | | TIMOTHY LARGE,PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-05-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-05-26 |
Time |
16:20 |
Rev Time |
2.75 |
| Received By |
tlarge |
Date |
2000-05-26 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | JOB SPECIFICATION 15000-SEC.1.04-THE | | | PLUMBING CODE IN EFFECT IS THE 1994 | | | EDITION OF THE STANDARD PLUMBING CODE. | | | REVISE THE SPECS.TO REFLECT THIS STAN- | | | DARD. | | | | | | SUBMIT OCCUPANT LOAD OF EACH AREA PER | | | SPC TABLE 407 FOR DETERMINATION OF MIN. | | | REQUIRED SANITARY FACILITIES.SEE SEC. | | | 407.1.3. FOR ALLOWED DEDUCTIBLE AREAS. | | | | | | DELETE REFERENCE TO THE UNIFORM BUILDING | | | CODES NOTED THROUGHOUT THE PLANS.THE | | | STANDARD BUILDING CODES ARE THE ADOPTED | | | STANDARDS.COUNTYWIDE AMENDMENTS TO SPC | | | SEC.101.1. | | | | | | SUBMIT A COMPLETE SANITARY AND WATER | | | ISOMETRIC FOR REVIEW.COUNTYWIDE AMEND- | | | MENTS TO SPC SEC.104.2.1. | | | | | | SUBMIT A GAS ISOMETRIC FOR REVIEW.SHOW | | | DISTANCE TO MOST REMOTE OUTLET,PIPE | | | SIZES,TYPE OF PIPING,TYPE OF GAS,BTU | | | LOAD OF EACH APPLIANCE,TOTAL BTU LOAD ON | | | THE SYSTEM,TYPE OF VENT,ETC.SGC SEC.302. | | | | | | SUBMIT CALCULATIONS FOR COMBUSTION AIR. | | | COMPLY W/SGC SEC.402.4. | | | | | | DRAINS FROM THE BAR AREA SHALL DISCHARGE | | | THROUGH THE GREASE INTERCEPTOR PER SPC | | | SEC.1004.4. | | | | | | DRAINS IN BAR AND KITCHEN AREAS SHALL | | | DISCHARGE TO THE BUILDING DRAINAGE SYS- | | | TEM THROUGH AN INDIRECT WASTE PER SPC | | | SEC.804.INSTALLATION OF INDIRECT WASTES | | | SHALL COMPLY W/SPC SEC.805.1,806,807. | | | | | | CAPACITY OF GREASE TRAP SHALL BE | | | APPROVED BY CITY OF WPB UTILITIES.SUBMIT | | | APPROVAL FORM FROM CITY OF WPB.CONTACT | | | R.COMPO AT(561)835-7423. | | | | | | TWO WAY CLEANOUTS ARE REQD.ON THE INLET | | | AND OUTLET TO THE GREASE TRAP PER SPC | | | SEC.710.4. | | | | | | SUPPLY MANUF.INSTALLATION INSTRUCTIONS | | | FOR POWER VENT INSTALLATION.COMPLY W/ | | | SGC SEC.610.3. | | | | | | BOTTOM FED WATER HEATERS SHALL BE | | | EQUIPPED W/VACUUM RELIEF VALVE PER SPC | | | SEC.507.1.2. | | | | | | NUMBER OF SANITARY FACILITIES SHALL | | | COMPLY W/FLA.STATUTE 553.141(1)(2)(3). |
|
|