Plan Review Details - Permit 00050035
Plan Review Stops For Permit 00050035
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-07-05 Cont ID  
Sent By dpalmer Date 2000-07-05 Time 20:11 Rev Time 0.00
Received By dpalmer Date 2000-07-05 Time 20:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-05-24 Cont ID  
Sent By dpalmer Date 2000-05-24 Time 20:44 Rev Time 0.00
Received By dpalmer Date 2000-05-24 Time 20:44 Sent To  
Notes
2001-01-08 00:00:00NOTES ATTACHED TO PLANS

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-11-08 Cont ID  
Sent By jleech Date 2000-11-08 Time 17:14 Rev Time 0.33
Received By jleech Date 2000-11-08 Time 17:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-05-15 Cont ID  
Sent By cthirben Date 2000-05-15 Time 07:33 Rev Time 1.00
Received By cthirben Date 2000-05-15 Time 07:33 Sent To  
Notes
2001-01-08 00:00:00******************PROVISO***************
 NOTES: SHOW ON THE PLANS THE VALUE OF
 THE CFM'S ON THE EXHAUST FANS.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-05-08 Cont ID  
Sent By tlarge Date 2000-05-08 Time 06:22 Rev Time 0.33
Received By tlarge Date 2000-05-08 Time 06:22 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 6 Status P Date 2000-09-28 Cont ID  
Sent By jgomez Date 2000-09-28 Time 13:47 Rev Time 0.25
Received By jgomez Date 2000-09-28 Time 13:47 Sent To  
Notes
2001-01-08 00:00:00APPROVAL OF ADDITIONAL INFORMATION FOR
 STELL COLUMN ANCHORING.

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2000-08-09 Cont ID  
Sent By jgomez Date 2000-08-09 Time 17:14 Rev Time 0.50
Received By jgomez Date 2000-08-09 Time 17:14 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-SEE COMMENTS ON PLANS.
  
  
  
  
  
  
 REMAINDER:
  
 PLEASE SUBMIT ITEMS REQUESTED ON PROVISO
 DATED 7-18-00 PRIOR TO CONSTRUCTION OR
 INSTALLATION, IN ORDER TO AVOID
 UNNECESSARY DELAYS OR CONFLICTS.
 THANK YOU. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2000-08-05 Cont ID  
Sent By jgomez Date 2000-08-05 Time 17:35 Rev Time 1.00
Received By jgomez Date 2000-08-05 Time 17:35 Sent To  
Notes
2001-01-08 00:00:00REVISION CHECKLIST:
 1-FOOTING F6 BETWEEN KITCHEN AND BATHRM
 #2 IS ENCROACHING INTO THE NEIGHBOR'S
 PROPERTY. THIS' A ZERO LOT LINE WALL.
 NOTE: DO YOU REALLY NEED THIS CONCRETE
 PAD. SEE ROOF FRAMING PLAN. ARCHITECT
 TO REVISE DRAWING AS REQUIRED.
 2-ROOF FRAMING PLAN:
 -SPECIFY CONNECTORS AT ALL BEARING
 POINTS. SOME ARE MISSING. THROUGHFULLY
 REVIEW ROOF FRAMING PLAN AND REVISE
 AS REQUIRED.
 -MAKE SURE THAT CONNECTORS SPECIFIED
 ARE FOR THE PROPER APPLICATION.
 WA CONNECTORS ARE FOR WOOD TO WOOD
 CONNECTIONS AND A1 THRU A-6 CONNECTORS
 ARE FOR CONCRETE TO WOOD CONNECTIONS.
 REVISE ROOF FRAMING PLAN AS REQUIRED.
  
  
 REMINDER:
 RESUBMIT ITEMS REQUESTED ON PROVISO
 DATED 7-18-00 PRIOR TO CONSTRUCTION OR
 INSTALLATION IN ORDER TO AVOID
 UNNECESSARY DELAYS OR CONFLICTS.
 THANK YOU.JG.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-07-18 Cont ID  
Sent By jgomez Date 2000-07-18 Time 10:39 Rev Time 2.00
Received By jgomez Date 2000-07-18 Time 10:39 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-REVISE ENERGY CALCULATIONS: THERE ARE
 FOUR BEDROOMS, NOT 3. SEE PLANS.
 2-PROFESSIONAL ENGINEER SHOULD NOT SEAL
 ORIGINAL DRAWINGS. SEC 61G15-23.002.
 ALSO, SURVEYOR TO PROVIDE WET
 SIGNATURE AND DATE WHEN SEALING DWG.
 3-PROVIDE PRODUCT APPROVAL FOR:
 -ONE HOUR FIRE RATED EGRESS PANEL.
 -DOUBLE ENTRY DOORS.
 -FRENCH DOORS.
 -GARAGE DOORS THAT MEET THE DESIGN
 PRESSURES CALCULATED BY THE ARCHITECT.
 -WINDOW MULLIONS.
 -FIXED WINDOWS WITH THE SIZES SHOWN AT
 THE GREAT ROOM.
 4-PROVIDE COMPLETE DETAIL/SPECIFICATIONS
 FOR CEILING CONSTRUCTION AT ENTRY AND
 REAR PORCH. INCLUDE FASTENER TYPE AND
 SPACING. SECTION 2504 SBC 1997.
 5-SPECIFY SIZE OF ATTIC ACCESS PANELS.
 SECTION 2309.6 SBC 1997.
 6-PROVIDE COMPLETE CONNECTION DETAIL AT
 BOTTOM OF STEEL COLUMNS. SEC 104.2.2
 7-REVISE TYPICAL WALL SECTION AND
 FOUNDATION NOTES. MINIMUM 6 MIL VAPOR
 BARRIER. SECTION 1909.2 SBC 1997.
 8-SPECIFY SIZE OF CEILING FANS AS PER
 TABLE 6-6 OF FLORIDA ENERGY EFFICIENCY
 CODE FOR BUILDING CONSTRUCTION, 1997
 9-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM:
 -MEAN ROOF HEIGHT IS WRONG. MEAN ROOF
 HEIGHT IS TAKEN FROM GRADE, NOT FROM
 FINISH FLOOR, TO THE AVERAGE POINT OF
 THE HIGHEST ROOF.
 -SEE CHAPTER 16 OF SBC 1997 FOR THE
 CORRECT VALUES FOR THE BASIC VELOCITY
 PRESSURE AND THE IMPORTANCE FACTOR.
 10-PROVIDE COPIES OF THE SOIL TESTS DONE
 AS PER SEC 1804.2.7.3 CITY AMENDMENTS
 11-ARCHITECT'S GENERAL NOTES ON SHEET GN
 SPECIFIES WINDOWS, DOORS AND ROOF TILE
 WHICH ARE DIFFERENT FROM THE PRODUCT
 APPROVALS SUBMITTED. ARCHITECT TO
 APPROVE ALL PRODUCT APPROVALS PRIOR TO
 SUBMITTAL TO THIS OFFICE.
 12-SEE COMMENTS ON PLANS, INCLUDING
 THOSE BY THE OTHER TRADES AND REVISE
 ORIGINALS AS REQUIRED.
  
  
 NOTE:
  
 INFORMATION REQUESTED ON THIS PROVISO
 SHALL BE SUBMITTED PRIOR TO INSTALLATION
 TO AVOID CONFLICT OR DELAYS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-07-12 Cont ID  
Sent By jgomez Date 2000-07-12 Time 16:22 Rev Time 3.50
Received By jgomez Date 2000-07-12 Time 16:22 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-IMPACT FEES WERE NOT PAID.
 2-REVISE ENERGY CALCULATIONS: THERE ARE
 FOUR BEDROOMS, NOT 3. SEE PLANS.
 3-PROFESSIONAL ENGINEER SHOULD NOT SEAL
 ORIGINAL DRAWINGS. SEC 61G15-23.002.
 4-PROVIDE PRODUCT APPROVAL FOR:
 ONE HOUR FIRE RATED EGRESS PANEL,
 FRENCH DOOR, DOUBLE ENTRY DOORS,
 GARAGE DOORS THAT MEET THE DESIGN
 PRESSURES CALCULATED BY THE ARCHITECT,
 SLIDING GLASS DOORS THAT MEET THE
 DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT, WINDOW MULLIONS, FIXED
 WINDOWS WITH THE SIZES SHOWN AT THE
 GREAT ROOM.
 5-PROVIDE COMPLETE DETAIL/SPECIFICATIONS
 FOR CEILING CONSTRUCTION AT ENTRY AND
 REAR PORCH. INCLUDE FASTENER TYPES AND
 SPACING. SECTION 2504 SBC 1997.
 6-REVISE DETAIL 6 OF A-9: HEIGHT OF WALL
 AT ATRIUM TO BE UP TO THE BOTTOM OF
 WINDOW LINTEL.
 7-SPECIFY SIZE OF ATTIC ACCESS PANELS.
 SECTION 2309.6 SBC 1997.
 8-PROVIDE COMPLETE DETAIL/SECTION AT
 FOYER STAIR. SEC 104.2.2 CITY AMENDMTS
 9-SPECIFY INSTALLATION DETAIL OF STEEL
 COLUMNS. BOTTOM PLATE. SEC 104.2.2
 CITY AMENDMENTS.
 10-REVISE TYPICAL WALL SECTION AND
 FOUNDATION NOTES. MINIMUM 6 MIL VAPOR
 BARRIER. SECTION 1909.2 SBC 1997.
 11-SPECIFY SIZES OF CEILING FANS. SEE
 TABLE 6-6 FLORIDA ENERGY EFFICIENCY
 CODE FOR BULDING CONSTRUCTION, 1997 ED
 12-REVISE THE DESIGN CERTIFICATION FOR
 BULDING CODE COMPLIANCE FORM. THE MEAN
 ROOF HEIGHT IS INCORRECT (MEAN ROOF HT
 IS TAKEN FROM GRADE TO THE AVERAGE
 POINT OF THE HIGHEST ROOF.
 -SEE CHAPTER 16 OF SBC 1997 FOR THE
 CORRECT VALUES FOR THE BASIC VELOCITY
 PRESSURES AND THE IMPORTANCE FACTOR.
 13-PROVIDE COPIES OF THE SOIL TEST DONE
 AS PER SECTION 1804.2.7.3 OF CITY
 AMENDMENTS.
 14-ARCHITECT'S GENERAL NOTES ON SHEET GN
 SPECIFIES WINDOWS, DOORS AND ROOF TILE
 WHICH ARE DIFFERENT FROM THE PRODUCT
 APPROVALS SUBMITTED. ARCHITECT TO
 APPROVE ALL PRODUCT APPROVALS PRIOR TO
 SUBMITTAL TO THIS OFFICE.
 15-OWES $ 314.73 FOR LOW VALUATION AND
 RADON FEES.
 16-SEE COMMENTS ON PLANS AND REVISE/
 UPDATE ALL ORIGINALS AS REQUIRED.
  
 NOTE:
 PLEASE RETURN REVIEWED SET AFTER ALL
 CORRECTIONS ARE DONE, IN ORDER TO
 EXPEDITE THE REVIEW PROCESS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-06-15 Cont ID  
Sent By tmoore Date 2000-06-15 Time 16:07 Rev Time 4.00
Received By tmoore Date 2000-06-15 Time 16:06 Sent To  
Notes
2001-01-08 00:00:00 
  
 *****************PROVISO****************
  
 SBC 104.2.2
  
 1)NEED PRODUCT APPROVALS FOR ALL
 OUTSWING DOORS.
  
 2)NEED PRODUCT APPROVAL FOR 18'
 GARAGE DOOR.
  
 3)PROVIDE SAFETY GLASS AS RELQUIRED.
 S.B.C. 2405.2.1
  
 4)OWE IMPACT FEES.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-05-04 Cont ID  
Sent By gjoyce Date 2000-05-04 Time 08:52 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***