Plan Review Details - Permit 00041284
Plan Review Stops For Permit 00041284
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-06-07 Cont ID  
Sent By hpiskura Date 2000-06-07 Time 07:46 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00LETTER ATTACHED TO APP

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-05-31 Cont ID  
Sent By jleahy Date 2000-05-31 Time 14:09 Rev Time 2.30
Received By jleahy Date 2000-05-31 Time 14:01 Sent To  
Notes
2001-01-08 00:00:001- NO PANEL SCHEDULES SHOWN
  
 2- NO LOAD CALCULATIONS SHOWN
  
 3- OUTLET SPACING SHOWN DOES NOT MEET
 LOCAL CODE

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2000-06-06 Cont ID  
Sent By mgonzale Date 2000-06-06 Time 07:30 Rev Time 2.00
Received By mgonzale Date   Time   Sent To  
Notes
2001-01-08 00:00:00PASSED WITH PROVISOS
  
 METER MUST BE LOCATED JUST OUTSIDE OF
 R.O.W. LINE AND BACKFLOW JUST INSIDE
 OF PROPERTY LINE.
  
 EACH SERVICE MUST BE TAPPED SEPERATELY.
  
 NO SADDLE TAPS ALLOWED, ONLY DIRECT TAPS
  
 IF THE PAVEMENT REMOVAL AREA SHOWN IS
 FOR WATER SERVICE THEN IT IS IN THE
 WRONG LOCATION.
  
 PLACE NOTE REFERING TO OUR STANDARD
 PAVEMENT REPLACEMENT DETAIL.
  
 SHOP DRAWINGS MUST BE PROVIDED TO
 MANNY GONZALEZ, PROJECT SPECIALIST
 AT CITY OF WEST PALM BEACH
 PUBLIC UTILITIES ENGINEERING
 1000 45TH ST
 WEST PALM BEACH, FL 33407
 561-659-8040 EXT. 2306

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-06-01 Cont ID  
Sent By rturnque Date 2000-06-01 Time 14:11 Rev Time 1.00
Received By rturnque Date   Time   Sent To  
Notes
2001-01-08 00:00:00FIRE HYDRANT SHALL BE LOCATED W/I 150 FT
 OF FIRE DEPARTMENT CONNECTION.
 EMERGENCY LIGHTS SHALL BE SO LOCATED AS
 TO PROVIDE THE REQUIRED ILLUMINATION IN
 THE EVENT OF ANY INTERRUPTION OF NORMAL
 LIGHTING.
 PROVIDE PANIC HARDWARE ON ALL DESIGNATED
 EXIT DOORS.
 ANY USABLE SPACE UNDER STAGE SHALL BE
 PROTECTED BY FIRE SPRINKLERS.
 STAGE REQUIREMENTS SHALL COMPLY WITH
 SECTION 8-3, OF THE 1985 LIFE SAFETY
 CODE.
 FIRE ALARM SYSTEM SHALL BE CLASS "A"
 OR ADDRESSABLE.
 INTERIOR FINISH SHALL BE CLASS A OR B.
 KITCHEN HOOD EXTINGUISHING SYSTEM SHALL
 BE CONNECTED TO FIRE ALARM SYSTEM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-05-09 Cont ID  
Sent By cthirben Date 2000-05-09 Time 13:53 Rev Time 0.00
Received By cthirben Date 2000-05-09 Time 14:15 Sent To  
Notes
2001-01-08 00:00:00*****************DENIED*****************
 INSUFFICIENT INFORMATION PROVIDED FOR
 REVIEW.
 OUTSIDE-AIR NEEDS TO BE ASHRAE 62-89 EG:
 LOCKER ROOM=60 CFM/PERSON.
 PROVIDE AIRBALANCE SCHEDULE PER 1997 SMC
 501.2
 PROVIDE GRILLE SIZES CFM VALUE, DUCT
 SIZES FOR RETURN AIR & SUPPLY AIR.

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-05-23 Cont ID  
Sent By tlarge Date 2000-05-23 Time 16:12 Rev Time 6.50
Received By tlarge Date 2000-05-23 Time 16:12 Sent To  
Notes
2001-01-08 00:00:00CONTINUATION OF PLUMBING COMMENTS:
 24)CIRCUIT AND LOOP SYSTEM SHALL COMPLY
 W/SPC SEC.914.1,914.2.
  
 25)A VENT IS REQD.BETWEEN THE SHOWER AND
 THE JANITOR SINK.SPC SEC.901.2.
  
 26)WATER CLOSETS AND FIXTURE DRAINS ARE
 NOT PERMITTED ON WET VENTS PER COUNTY-
 WIDE AMENDMENTS TO SPC SEC.911.1.1.
  
 27)TWO WATER CLOSETS SHALL BE VENTED PER
 COUNTYWIDE AMENDMENTS SEC.911.1.3.
  
 28)FIXTURES DOWNSTREAM OF WATER CLOSETS
 SHALL BE VENTED PER SPC SEC.913.2.
  
 29)SUBMIT COMPLETE SANITARY AND WATER
 RISERS FOR ALL AREAS.(KIT.,3RD.FLR.,ETC.
  
 30)SANITARY RISER SHALL CORRELATE W/
 FLOOR PLAN.COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.1.
  
 31)A PERMIT MAY BE REQD.FROM DEPT.OF
 ENVIRONMENTAL PROTECTION FOR THE WATER
 AND SANITARY LINE.COUNTYWIDE AMENDMENTS
 TO SPC SEC.101.4.7.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-05-23 Cont ID  
Sent By tlarge Date 2000-05-23 Time 13:41 Rev Time 0.00
Received By tlarge Date 2000-05-23 Time 13:41 Sent To  
Notes
2001-01-08 00:00:001)SUBMIT COPY OF JOB SPECIFICATIONS FOR
 REVIEW.COUNTYWIDE AMENDMENTS TO SPC SEC.
 104.2.1.,104.2.2.
  
 2)ALL DRAWINGS SHALL BE SIGNED/SEALED
 PER COUNTYWIDE AMENDMENTS TO SBC SEC.
 104.2.3,FLA.STATUTE 471 & 481.
  
 3)SUBMIT OCCUPANT LOAD BASED UPON
 HABITABLE FLOOR SPACE AS MANDATED BY SPC
 SEC.407.1.3.MINIMUM SANITARY FACILITIES
 SHALL BE BASED UPON THIS OCCUPANT LOAD.
  
 4)AN ADDITIONAL STALL 36" WIDE W/
 PARALLEL GRAB BARS & OUTSWINGING DOOR
 SHALL BE PROVIDED PER FACBC SEC.4.22.4.
  
 5)NUMBER OF SANITARY FACILITIES SHALL
 COMPLY W/FLA.STATUTE 553.141.(3)."POTTY
 PARITY"
  
 6)DRESSING ROOMS SHALL COMPLY W/FACBC
 SECS.4.1.3(21),4.35.1-4.35.5.(A BENCH IS
 REQD.IN THE ROOM.)
  
 7)ALL PUBLIC USE AND COMMON USE TOILET
 ROOMS SHALL BE ACCESSIBLE PER FACBC
 SEC.4.1.3(11)
  
 8)DOORS SHALL NOT SWING INTO THE CLEAR
 FLOOR SPACE REQD.REQUIRED FOR ANY
 FIXTURE PER FACBC SEC.4.22.2.(SEE
 URINALS IN ROOMS 107,206.
  
 9)THE PLUMBING CODE IN EFFECT IS THE
 1994 EDITION.PLUMBING DESIGN,FIXTURES,
 ETC.SHALL CONFORM TO THIS STANDARD.
  
 10)SUBMIT COMPLETE STORM DRAINAGE
 ISOMETRIC.SHOW ALL PIPE SIZES,SQ.FOOT
 AREA DRAINED BY EACH DRAIN,SLOPE OF PIPE
 ETC.COMPLY W/SPC SEC.1108.1,1108.2 FOR
 CORRECT SIZING.
  
 11)MOUNTING HEIGHTS/DIMENSIONS FOR H.C.
 APPURTENANCES SHALL COMPLY W/FACBC 1997
 EDITION.
  
 12)SHOW LOCATION OF H.C.URINALS ON PLANS
 AND SHOW REQD.CLEAR FLOOR SPACE PER
 FACBC SEC.4.18.3.
  
 13)SHT.A-13-URINALS SHALL BE LOCATED TO
 ENSURE PRIVACY.(THEY ARE LOCATED IN THE
 LINE OF SIGHT FROM THE CORRIDOR.)RM.206.
  
 14.)SHT.A-13-ROOM#206-SIZE OF THE
 HANDICAP STALL SHALL COMPLY W/FACBC SEC.
 4.17.3.OF THE FACBC.(SEE EXCEPTION :NEW
 CONSTRUCTION.)
  
 15)SHT.A-13-SHOW THE CLEAR DIMENSIONS OF
 ALL H.C. TOILET STALLS.COMPLY W/FCBC
 SEC.4.17.3.
  
 16)SHOW RED.WHEELCHAIR TURNING SPACE IN
 THE TOILET ROOMS PER FACBC SEC.4.2.3.
  
 17)INDICATE ON PLAN IF A PUMP AND DRAIN
 LINE WILL BE INSTALLED IN THE ELEVATOR
 SUMP.IF SO,SUBMIT PIPING ISOMETRIC FOR
 REVIEW.IF ELEVATOR IS HYDRAULIC AN
 INTERCEPTOR WILL BE REQD.
  
 18)SHT.P01-GREASE TRAP DETAIL SHALL
 COMPLY W/CITY OF WPB STANDARDS.A TWO WAY
 CLEANOUT SHALL BE INSTALLED ENTERING AND
 LEAVING EACH INTERCEPTOR.
  
 19)CAPACITY OF GREASE TRAP SHALL BE
 APPROVED BY CITY OF WEST PALM BEACH
 UTILITIES.CONTACT R.COMPO OR BONNIE KAMP
 AT 835-7423.SUBMIT COPY OF APPROVAL FORM
 FROM UTILITIES.
  
 20)PLANSSHALL BE ROUTED TO DEPT.OF
 BUSINESS REGULATION FOR REVIEW.COUNTY-
 WIDE AMENDMENTS TO SPC SEC.101.4.7.
  
 21)A VACUUM RELIEF VALVE SHALL BE IN-
 STALLED ON THE COLD WATER SUPPLY TO THE
 WATER HEATER PER SPC.SEC.507.1.2.
  
 22)SUBMIT MANUF.SHEETS FOR ALL GAS
 EQUIPMENT.EQUIPMENT SHALL BE LISTED PER
 SGC SEC.402.1.
  
 23)SHT.P6-URINAL SHALL BE VENTED.SPC
 SEC.901.2.
 SEE STEP #2 FOR CONTINUATION OF PLBG.

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***