|
 |
 |
 |
 |
 |
Plan Review Details - Permit 00041035
| Plan Review Stops For Permit 00041035 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-05-30 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-05-30 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-09-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-21 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-21 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-05-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-04 |
Time |
06:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-04 |
Time |
06:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2000-06-02 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-06-02 |
Time |
09:05 |
Rev Time |
2.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PASSED WITH PROVISOS | | | PROJECT RECIEVED FOR ENG REVIEW 6/1/00 | | | | | | REVIEW COMMENTS FOR SHEET C-2 | | | | | | 1. DIRECT TAPS MUST BE CALLED OUT | | | SPECIFIYING SIZE AND INSTALLATION BY | | | CONTRACTOR. (NO SADDLE TAPS ALLOWED) | | | | | | 2. REDUCE PREASSURE ASSEMBLIES MUST BE | | | INSTALLED AS MARKED ON PLAN. | | | | | | 3. BACKFLOWS MUST BE INSTALLED IN THE | | | PROPERTY JUST INSIDE THE R.O.W. LINE. | | | | | | 4. METERS MUST BE INSTALLED JUST OUSIDE | | | OF THE R.O.W. | | | | | | 5. VERTICAL CLEARANCES MUST BE CALLED | | | OUT BETWEEN WATER AND SEWER. AN 18" | | | MINIMUM CLEARANCE IS REQUIRED. | | | | | | 6. MUST HAVE ON PLAN "SUNSHINE" LOCATING | | | SERVICE NOTE ALONG WITH THE TELEPHONE | | | NUMBER 1 800 432 4770. | | | | | | 7. SUPPLY STANDARD UTILITY DETAIL | | | DRAWINGS TO CONTRACTOR. THIS APPLY'S | | | TO SERVICES, BACKFLOW, CLEAN-OUTS, | | | AND LATERALS ETC. | | | | | | 8. SUBMITSHOP DRAWINGS TO PROJECT | | | COORDINATOR FOR WATER SERVICES AND STORM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-07-13 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-13 |
Time |
10:51 |
Rev Time |
0.65 |
| Received By |
tlarge |
Date |
2000-07-13 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-05-04 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-05-04 |
Time |
18:13 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-05-04 |
Time |
18:13 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DRINKING FOUNTAIN SHALL BE H.C.ACCESS- | | | IBLE AND BE LOCATED ON AN ACCESSIBLE | | | ROUTE PER FACBC SEC.4.1.1,4.1.2.,4.3. | | | PROVISIONS SHALL BE MADE FOR PEOPLE WHO | | | HAVE TROUBLE BENDING OR STOOPING. | | | | | | WATER LINE TO DRINKING FOUNTAIN SHALL BE | | | EQUIPPED W/BQCKFLOW PER SPC SEC.606.1, | | | 606.2. | | | | | | INDICATE ON PLAN HOW WASTE WATER FROM | | | DRINKING FOUNTAIN WILL BE DISPOSED. | | | WASTE SHALL BE CONNECTED TO SANITARY | | | SYSTEM.SPC SEC.301.11.1. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-04-25 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-04-25 |
Time |
09:13 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |