Plan Review Details - Permit 00040991
Plan Review Stops For Permit 00040991
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-05-25 Cont ID  
Sent By dpalmer Date 2000-05-25 Time 16:58 Rev Time 0.00
Received By dpalmer Date 2000-05-25 Time 16:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-04-27 Cont ID  
Sent By dpalmer Date 2000-04-27 Time 06:12 Rev Time 0.00
Received By dpalmer Date 2000-04-27 Time 06:12 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE: NEED TO SHOW DETAIL ON ALL THE
 ELECTRICAL WORK BEING DONE.
 PLEASE GIVE IN DETAILS.
 PLEASE SUBMIT THE SIZE OF THE EXISTING
 SERVICE.
  
 2)NOTE: AS PER 210-11-C-3 BATH(S) REQ`
 A SEPARATE 20 AMP CIRCUIT #12 AWG.
  
 3)ALSO OUTLET SPACING TO MEET CODE ON
 INTERIOR WALLS.
  
 4)NOTE: MEANS OF EGRESS LIGHTING FOR
 EACH ROOM 210-70
  
 5)NOTE: SMOKE DETECTORS ARE GOING TO BE
 REQ`D INSDIE AND OUTSIDETHE BEDROOM.
 NFPA-72 2-2.1.1.1
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL. 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-04-28 Cont ID  
Sent By cthirben Date 2000-04-28 Time 07:47 Rev Time 1.00
Received By cthirben Date 2000-04-28 Time 07:46 Sent To  
Notes
2001-01-08 00:00:00****************DENIED******************
 MECHANICAL PLAN TO BE SUBMITTED.

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-05-26 Cont ID  
Sent By tlarge Date 2000-05-26 Time 07:30 Rev Time 0.30
Received By tlarge Date 2000-05-26 Time 07:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-04-28 Cont ID  
Sent By tlarge Date 2000-04-28 Time 06:26 Rev Time 0.50
Received By tlarge Date 2000-04-28 Time 06:26 Sent To  
Notes
2001-01-08 00:00:00 
 SHOWER SHALL BE A MIN.OF 30"WIDE AND
 A MIN.OF 1024 SQ.IN.FLOOR AREA PER
 COUNTYWIDE AMENDMENTS TO SPC SEC.409.8.2
  
 SUBMIT SANITARY RISER AND WATER SUPPLY
 RISER PRIOR TO ROUGH PLBG.INSPECTION.
  
 FIXTURES SHALL BE WATER CONSERVATION
 TYPE PER SPC SEC.406.
  
 SUBMIT TWO COPIES OF FLOOR PLAN.COUNTY-
 WIDE AMENDMENTS TO SPC SEC.104.2.1.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-05-26 Cont ID  
Sent By lmartine Date 2000-05-26 Time 07:36 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-05-15 Cont ID  
Sent By lmartine Date 2000-05-15 Time 16:29 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2000-04-24 Cont ID  
Sent By gjoyce Date 2000-04-24 Time 11:02 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***