| Plan Review Stops For Permit 00040985 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2000-07-12 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-07-12 |
Time |
14:47 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2000-06-27 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-06-27 |
Time |
11:42 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. CHANGES TO EXTERIOR ELEVATION NOT | | | APPROVED BY CITYPLACE. | | | 2. FLORIDA ENERGY SHEETSW NOT SIGNED BY | | | OWNER. OK 7/5/00 | | | 3. LETTER RELEASING SPACE FROM SPECIAL | | | INSPECTOR OK 7/5/00, ORIGIONAL RECEIVED. | | | 4. FIRE SPRINKLER PERMIT REQUIRED | | | PRIOR TO ISSUANCE OF BUILDING PERMIT. | | | 5. ELEVATION REVIEWED BY JOHN COLLIER RE | | | TELEPHONE NO APPROVAL ISSUED 7/5/00. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-06-16 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-06-16 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. FLORIDA ENERGY SHEETS NOT SUBMITTED. | | | 2. LETTER FROM CITYPLACE ENGINEER NOT | | | SUBMITTED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-05-24 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-05-24 |
Time |
11:34 |
Rev Time |
3.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. FLORIDA ENERGY SHEETS 1997 CODE. | | | 2. LETTER FROM CITYPLACE ENG. RELEASING | | | SPACE FOR BUILDOUT PERMIT. | | | 3. SHEET G-1 CODE REFERENCE REVISE NOTE1 | | | A.BUILDING CODE IS 1997 SBC AS AMENDED | | | BY THE CITY OF WPB. | | | B. MECHANICAL CODE IS 1997 SBC AS | | | AMENDED BY THE CITY OF WPB. | | | C. NOTE 21: ALL EXTERIOR GLSAZING SHALL | | | COMPLY WITH THE 1997 SBC AND CITY OF WPB | | | AMENDMENTS FOR LARGE MISSLE IMPACT | | | PROTECTION. | | | D. PLUMBING CODE IS 1994 SBC AS AMENDED | | | BY THE CITY OF WPB. | | | E. ELECTERICAL CODE IS THE 1997 NEC AS | | | AMENDED BY THE CITY OF WPB. | | | F. FLORIDA ENERGY CODE IS THE 1997 | | | EDITION. | | | 4. FIRE SPRINKLER CONTRACTOR TO APPLY | | | FOR PERMIT. | | | 5. SHEET A-6 SECTION A, ALL FIRE | | | SEPERATIONS ARE TO BE FINISHED ON BOTH | | | SIDES. | | | 6. SIGNS REQUIRE SEPERATE PERMITS. | | | 7. BUILDING IS TYPE II CONSTRUCTION | | | 1997 SBC ALL WOOD PRODUCTS SHALL BE | | | INSTALLED ACCORDING TO THE APPLICABLE | | | CODE SECTIONS. | | | 8. GLAZING: PROVIDE PRODUCT APPROVAL | | | INFORMATION INDICATING COMPLIANCE WITH | | | THE 1997 SBC CHAPTER 16 AS AMENDED BY | | | THE CITY OF WPB. METRO DADE COUNTY OF | | | SBCCI PRODUCTS ARE ACCEPTABLE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2000-11-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-27 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-27 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2000-07-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-13 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-13 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-27 |
Time |
21:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-27 |
Time |
21:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2000-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-09 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-09 |
Time |
21:24 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO ELECTRICAL SHEETS SUBMITTED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-04-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-04-27 |
Time |
19:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-04-27 |
Time |
19:50 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** PROVISO ************** | | | | | | 1)NOTE: PLEASE CORRECT THE EQUIPMENT | | | GROUNDING CONDUCTOR YOU SHOW ON E-4. | | | AS PER 250-122 OF THE '99' NEC 400 AMP | | | OC PROTECTION REQ`S #3. | | | | | | 2)NOTE: ALSO FOR THE COLOR CODING ON E-5 | | | YOU SHOW FOR 277/480 GRAY AND WHITE WITH | | | STRIPE. UNDER THE LOCAL AMENDMENTS ART; | | | 215, 277/480 REQ`S ONLY GRAY. | | | PLEASE REMOVE THE WORDING FOR WHITE W/ | | | STRIPE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW BEFORE ANY ROUGH ELECTRICAL | | | INSPECTION IS CALLED IN. IF THERE ARE | | | ANY QUESTIONS PLEASE CALL (561)659-8096 | | | EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-07-05 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-07-05 |
Time |
11:02 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO M. CARSILLO, PROVIDE EMERGENCY | | | LIGHTING IN SALES AREA. 6/29/00. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-05-15 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-05-15 |
Time |
15:12 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SEE M. CARSILLO NOTES ATTACHED TO PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-08-07 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-08-07 |
Time |
08:02 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-08-07 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO; | | | SAFE ROOM: PROVIDE MANUFACTURERDETAIL- | | | ED INFORMATION TO INDICATE CODE COMPLI- | | | ANCE WITH SMC SECTION 403 PRIOR TO INSU- | | | LATION. SCHEDULE PRE-INSPECTION PRIOR TO | | | INSTALLING | | | | | | ATTACH DIFFUSERS AS REQUIRED BY FLORIDA | | | ENERGY CODE 1997 EDITION, SECTION 410. | | | 1ABCD.3.3. PROVIDE INFORMATION AND SCHE- | | | DULE PRE-INSPECTION PRIOR TO INSTALLING | | | SYSTEM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-07-05 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-07-05 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
cthirben |
Date |
2000-08-07 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. SAFE ROOM: PROVIDE MANFACTURES | | | DETAILED INFORMATION TO INDICATE CODE | | | COMPLIANCE WITH SMC SECTION 403 PRIOR | | | TO INSTULLATION. SCHEDULE PRE INSPECTION | | | PRIOR TO INSTALLING. | | | 2. ATTACH DIFUSER AS REQUIRED BY FLORIDA | | | ENERGY CODE 1997 EDITION, SECTION | | | 410.1ABCD.3.3. PROVIDE INFORMATION AND | | | SEHEDULE PRE INSPECTION PRIOR TO | | | INSTALLING SYSTEM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-05-01 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-05-01 |
Time |
07:08 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-05-01 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************DENIED********************* | | | | | | 1) EXHAUST FANS NOTE 2 SHOW VENT TO | | | ABOVE CEILING SPACE. 1997 SMC 501.3 | | | REQUIRES ALL EXHAUST TO BE DISCHARGED | | | OUTDOORS. | | | 2) SAFE ROOM SHOWS NO VENTILATION. | | | 1997 SMC 403 REQUIRES EVERY PORTION OF | | | EVERY BUILDING TO BE VENTILATED IN | | | ACCORDANCE WITH ASHRAE 62-89 | | | 3) DIFFUSER DETAIL INDICATES FLEX | | | ATTACHMENT METHOD. NOTE METHOD TO COMPLY | | | WITH ENERGY EFFICIENCY CODE FOR BLDG | | | CONSTRUCTION 1997 410.1ABCD.3.3 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2000-11-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-28 |
Time |
16:36 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2000-11-28 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2000-07-12 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-12 |
Time |
15:56 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-07-12 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2000-07-05 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-05 |
Time |
09:10 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-07-05 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************PROVISO****************** | | | WATER HEATER SHALL BE READILY ACCESSIBLE | | | PER SPC SEC.501.7.SUPPLY FIXED LADDER | | | FOR ACCESS OR RELOCATE EWH TO FLOOR. | | | | | | PROVISIONS SHALL BE MADE AT DRINKING | | | FOUNTAIN FOR PEOPLE WHO HAVE TROUBLE | | | BENDING OR STOOPING.FACBC SEC.4.1.3.(10) | | | (A). | | | | | | SUBMIT MANUF.SHEETS FOR STEAMER UNITS. | | | MAX.TEMPERATURE OF WASTE DISCHARGED TO | | | SANITARY SHALL BE 140 DEGREES PER SPC | | | SEC.717.8 | | | | | | FLOOR SINKS SHALL BE INSTALLED IN LIEU | | | OF HUB DRAINS AND SHALL BE OF A DESIGN | | | THAT PREVENTS SPLASHING PER SPC SEC. | | | 807.1.3. | | | | | | SHOW LOCATION OF 2ND.DRINKING FOUNTAIN | | | ON FLOOR PLAN.COUNTYWIDE AMENDMENTS TO | | | SPC SEC.104.2.1. | | | | | | IF YOU HAVE ANY QUESTIONS I CAN BE | | | REACHED AT 561-659-8096,EXT.8377. | | | | | | TIMOTHY LARGE,PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-06-12 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-12 |
Time |
18:04 |
Rev Time |
1.50 |
| Received By |
tlarge |
Date |
2000-06-12 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SINK AT KITCHEN AREA SHALL COMPLY | | | W/FACBC SECS.4.24.1-4.24.7. | | | | | | CLEARLY SHOW LOCATION OF DRINKING | | | FOUNTAIN AND COMPLIANCE W/FACBC SEC. | | | 4.1.3.(10)(A). | | | | | | WATER HEATER SHALL BE READILY ACCESSIBLE | | | PER SPC SEC.501.7.PROVIDE FIXED LADDER | | | OR RELOCATE TO FLOOR. | | | | | | SHOW DRINKING FOUNTAIN ON SANITARY AND | | | WATER RISER.DRINKING FOUNTAIN SHALL | | | COMPLY W/FACBC SEC.4.1.3.(10)(A). | | | PROVISIONS SHALL BE MADE FOR PEOPLE WHO | | | HAVE TROUBLE BENDING OR STOOPING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-04-29 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-04-29 |
Time |
10:17 |
Rev Time |
1.25 |
| Received By |
tlarge |
Date |
2000-04-29 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT SQ.FOOTAGE OF HABITABLE FLOOR | | | SPACE TO ENSURE COMPLIANCE W/TABLE 407 | | | OF SPC 1994 EDITION.REFER TO SEC.407.1.3 | | | FOR ALLOWED DEDUCTIBLE AREAS. | | | | | | PLANS SHALL BEAR CITY PLACE LANDLORD | | | APPROVAL STAMPS. | | | | | | SINK AT KITCHEN AREA SHALL COMPLY W/ | | | FACBC SECS.4.24.1-4.24.7. | | | | | | SANITARY FACILITIES AND DRINKING | | | FOUNTAIN SHALL BE ACCESSIBLE TO THE | | | PUBLIC PER SPC SEC.407.2.2. | | | | | | DRINKING FOUNTAIN SHALL COMPLY W/FACBC | | | SEC.4.1.3.(10)(A),4.15.PROVISIONS SHALL | | | BE MADE FOR PERSONS WHO HAVE TROUBLE | | | BENDING OR STOOPING.SUBMIT DETAIL. | | | | | | SHOW DIMENSIONS OF TOILET ROOMS.SIZE AND | | | CLEAR FLOOR SPACE FOR FIXTURES SHALL | | | COMPLY W/FACBC SEC.4.16,FIG.28. | | | | | | SHT.A-17-LENGTH OF GRAB BARS BEHIND AND | | | ALONG SIDE WATER CLOSETS SHALL COMPLY | | | W/FACBC SECS.4.16.4,FIG.#29. | | | | | | HEIGHT OF TOWEL DISPENSERS SHALL COMPLY | | | W/FACBC SEC.4.2.5, 4.2.6. | | | | | | SHOW HEIGHT OF H.C.WATER CLOSET.COMPLY | | | W/FACBC SEC.4.16.3. | | | | | | CLEAR FLOOR SPACE UNDER H.C.LAV.SHALL | | | COMPLY W/FACBC SEC.4.19.2. | | | | | | WATER HEATER SHALL BE READILY ACCESSIBLE | | | PER SPC SEC.501.7.PROVIDE FIXED LADDER | | | OR RELOCATE TO FLOOR. | | | | | | SUBMIT MANUF.SHEETS FOR STEAMERS.MAX. | | | TEMP.OF WATER TO SANITARY SHALL BE 140 | | | DEGREES PER SPC SEC.717.8. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-05-15 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-04-24 |
Time |
11:40 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
2000-05-15 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|