| Plan Review Stops For Permit 00040867 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-07-27 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2000-07-27 |
Time |
08:49 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ADD'L WALLS IN BATHS TO ADD PLUMBING FIX |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-05-05 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-05-05 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-06-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-28 |
Time |
20:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-28 |
Time |
20:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-06-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-05 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-05 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE THAT OUTLET SPACING | | | TO MEET LOCAL CODE; 210-50 EVERY 20` OF | | | UNENCUMBERED WALL. | | | | | | 2)NOTE: YOUSHOW ON E-4 TWO DIFFERENT | | | FEEDER SCHEDULES?? PLEASE SHOW CORRECT | | | SCHEDULE. ONE SHOWS 2-SETS OF 500 AND | | | THE OTHER SHOWS 3-SETS OF 600 MCM?? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-03 |
Time |
19:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-03 |
Time |
19:40 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT ******************* | | | | | | 1)NOTE: NEED TO SHOW THE REQ`D OUTLETS | | | FOR SHOW WINDOWS AS PER 210-62 | | | REVISE PANEL SCHEDULE. | | | | | | 2)NOTE: NEED TO SUBMIT THE LOAD CALCS | | | SHOWING ALL CONTINUOUS LOADS AT 125% | | | THIS WOULD BE LIGHTING OR ANY OTHER LOAD | | | EXPECTED TO RUN FOR 3 OR MORE HOURS PER | | | ART;22-3-B-7 AND 210-20 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATIONFOR | | | REVIEW. PLANS WOULD HAVE PASSED WITH | | | PROVISO BUT THEY WERE COMING BACK FOR | | | OTHER COMMENTS. IF THERE ARE ANY QUEST- | | | -IONS PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-06-08 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-06-08 |
Time |
14:26 |
Rev Time |
0.15 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-04-20 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-04-20 |
Time |
10:38 |
Rev Time |
0.30 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVIDE FIRE SPRINKLER DRAWINGS | | | PROVIDE SHOP DRAWINGS FOR FIRE ALARM | | | SYSTEM AND FIRE SPRINKLER SYSTEM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-08-29 |
Time |
15:27 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-08-29 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-06-07 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-06-07 |
Time |
09:29 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-06-07 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-05-04 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-05-04 |
Time |
11:34 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-05-04 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************DENIED****************** | | | 1) OUTSIDE AIR PER ASHRAE 62-89 REQUIRED | | | 2) PROVIDE AIR BALANCE SCHEDULE TO SHOW | | | COMPLIANCE WITH 1997 SMC 501.2 | | | 3) OFFICE AREA SHOWS NO VENTILATION | | | 4) STOCKROOM SHOWS NO VENTILATION | | | VENTILATION REQUIRED FOR ALL PORTIONS OF | | | BUILDINGS REQUIRED PER 1997 SMC 403 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2000-07-13 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-13 |
Time |
10:00 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-07-13 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2000-07-05 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-05 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
tlarge |
Date |
2000-07-05 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ******************PROVISO*************** | | | THERE ARE LESS THAN THE REQUIRED NUMBER | | | OF SANITARY FACILITIES IN THE WOMEN'S | | | RESTROOM.REVISED PLANS ARE REQUIRED AND | | | PLUMBING PERMIT SHALL NOT BE ISSUED | | | UNTIL PLUMBING PLANS ARE APPROVED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-07-05 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-03 |
Time |
15:56 |
Rev Time |
0.75 |
| Received By |
pschmitz |
Date |
2000-07-03 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | THE MINIMUM NUMBER OF REQUIRED SANITARY | | | FACILITIES SHALL COMPLY W/SPC TABLE 407 | | | OF SPC.THERE ARE NOT ENOUGH FIXTURES IN | | | THE WOMEN'S RESTROOM.PLEASE COMPLY.THIS | | | COMMENT IS NOT GOING AWAY. | | | | | | URINAL SHALL BE MOUNTED AT 17"MAX.TO THE | | | RIM,NOT TO THE BOTTOM.FACBC SEC.4.18. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-07-05 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-04 |
Time |
07:38 |
Rev Time |
1.00 |
| Received By |
tlarge |
Date |
2000-06-04 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | THE MINIMUM REQUIRED PLUMBING FIXTURES | | | SHALL COMPLY W/TABLE 407 OF THE SPC.THE | | | NUMBER OF FIXTURES IN THE WOMEN'S REST- | | | ROOM ARE INSUFFICIENT ACCORDING TO THE | | | NOTED HABITABLE SQUARE FOOT AREA OF THE | | | SPACE. | | | | | | THE SIZE OF THE HANDICAP TOILET STALLS | | | DO NOT COMPLY W/FACBC SEC.4.17.3.SEE | | | EXCEPTION:NEW CONSTRUCTION.THE LAVATORY | | | CANNOT INFRINGE ON THE CLEAR FLOOR | | | SPACE FOR THE WATER CLOSET. | | | | | | URINAL SHALL BE MOUNTED AT 17"MAX.TO THE | | | RIM,NOT THE BOTTOM OF THE URINAL.FACBC | | | 4.18. | | | | | | A CLEANOUT IS REQD.IN THE UPSTREAM END | | | OF THE BUILDING DRAIN PER SPC SEC.710.2 | | | | | | NOTE:SHT.P-1-THE SQUARE FOOTAGE PER | | | PERSON FOR THIS OCCUPANCY PER TABLE 407 | | | OF THE SPC IS 200 SQ.FT.THE CODE SEC. | | | 403.1 OF THE SPC YOU REFERENCED ON THE | | | PLAN REFERS TO THE CLEANING OF PLUMBING | | | FIXTURES,NOT THE OCCUPANT LOAD.MY | | | CALCULATIONS SHOW 29,465 SQ.FT.WHICH | | | EQUALS AN OCCUPANT LOAD OF 148 PERSONS. | | | (CALCULATIONS ARE FROM HABITABLE FLOOR | | | SPACE SHOWN ON A-2.) |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-07-05 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-04-30 |
Time |
10:06 |
Rev Time |
1.00 |
| Received By |
tlarge |
Date |
2000-04-30 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SHOW SQ.FOOTAGE OF HABITABLE FLOOR SPACE | | | ON PLANS TO ENSURE COMPLIANCE W/SPC | | | TABLE 407 FOR MIN.PLUMBING FIXTURE REQS. | | | | | | LAVATORIES ARE REQUIRED IN THE | | | ACCESSIBLE STALLS PER FLA.ACCESS.CODE | | | FOR BUILDING CONSTRUCTION SEC.4.17.3. | | | RESTROOMS SHALL FULLY COMPLY W/FACBC | | | OCT.1997 EDITION. | | | | | | SHOW INSIDE CLEAR DIMENSIONS (LXW) OF | | | ACCESSIBLE STALLS AND STANDARD STALLS. | | | COMPLY W/FACBC 4.17.3.,FIG.#30, SPC SEC. | | | 403.4. | | | | | | SHT.A-4-ACCESSIBLE WATER CLOSET SHALL BE | | | 18"FROM WALL,NOT 36" AS SHOWN PER FACBC | | | FIGURE 30. | | | | | | SHOW HEIGHT OF URINAL.COMPLY W/FACBC SEC | | | 4.18. | | | | | | MIN.CLEAR FLOOR SPACE UNDER DRINKING | | | FOUNTAIN SHALL BE 27"PER FACBC SEC.4.15. | | | | | | WATER HEATER SHALL BE READILY ACCESSIBLE | | | PER SPC SEC.501.7.SUPPLY FIXED LADDER | | | OR RELOCATE WATER HEATER TO FLOOR. | | | | | | WATER SUPPLY CONTROL SHALL COMPLY W/SPC | | | SEC.610.4.1,610.4.2. | | | | | | SHOW REQD.WHEELCHAIR TURNING SPACE IN | | | RESTROOMS PER FACBC SEC.4.2.3. |
|
|