Plan Review Details - Permit 00040050
Plan Review Stops For Permit 00040050
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-05-02 Cont ID  
Sent By dpalmer Date 2000-05-02 Time 20:57 Rev Time 0.00
Received By dpalmer Date 2000-05-02 Time 20:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-04-15 Cont ID  
Sent By cthirben Date 2000-04-15 Time 10:33 Rev Time 0.50
Received By cthirben Date 2000-04-15 Time 10:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-06-16 Cont ID  
Sent By tlarge Date 2000-06-16 Time 19:24 Rev Time 0.25
Received By tlarge Date 2000-06-16 Time 19:24 Sent To  
Notes
2001-01-08 00:00:00REVISED SANITARY RISER.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-04-18 Cont ID  
Sent By tlarge Date 2000-04-18 Time 20:00 Rev Time 0.33
Received By tlarge Date 2000-04-18 Time 20:00 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-08-03 Cont ID  
Sent By jgomez Date 2000-08-03 Time 10:12 Rev Time 0.50
Received By jgomez Date 2000-08-03 Time 10:12 Sent To  
Notes
2001-01-08 00:00:001-ENTRY DOORS PRODUCT APPROVAL IS FOR
 OUTSWING DOORS AND ARCHITECTURAL DWGS
 SHOW INSWING DOORS. PROVIDE REVISED
 ARCHITECTURAL PLAN.
 2-ENTRY DOORS PRODUCT APPROVAL REQUIRES
 A 2X BUCK DETAIL. ARCHITECT/ENGINEER
 TO PROVIDE STRUCTURAL BUCK DETAIL
 SHOWING A 2X.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-05-22 Cont ID  
Sent By jgomez Date 2000-05-22 Time 17:57 Rev Time 2.00
Received By jgomez Date 2000-05-22 Time 17:57 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE ROOF FRAMING PLAN SHOWING THE
 CALCULATED UPLIFT LOADS AND ANCHOR
 SCHEDULE. SEC. 104.2.2 CITY AMENDMENTS
 2-REVISE THE DESIGN CERTIFICATIONFOR
 BUILDING CODE COMPLIANCE. MEAN ROOF
 HEIGHT IS 23'-6" PLUS OR MINUS, NOT
 20'-0". MEAN ROOF HEIGHT IS TAKEN FROM
 GRADE, NOT FROM FINISH FLOOR, TO THE
 AVERAGE POINT OF THE HIGHEST ROOF.
 3-PRODUCT APPROVALS:
 -PROVIDE PRODUCT APPROVAL FOR GOLFCART
 GARAGE DOOR.
 -FRENCH DOOR PRODUCT APPROVAL: DRAWINGS
 ARE NOT LEGIBLE.
 -PROVIDE PRODUCT APPROVAL FOR "INSWING"
 ENTRY DOORS.
 4-CLARIFY SIZE OF FOOTING F-1. SHEET 1
 SAYS 18"X18" AND SHEET 6 SAYS 20"X18".
 5-PROVIDE COMPLETE SET OF ENGINEERED
 ROYAL WALL PANELS SHOWING ALL CONCRETE
 THICKNESS AND REINFORCEMENT. SIGNED,
 SEALED AND DATED.
 SECTION 104.2.2 CITY AMENDMENTS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-04-04 Cont ID  
Sent By gjoyce Date 2000-04-04 Time 16:42 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***