| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: |
| | 1-FLOOD ZONE 'AO". WILL NEED TO PROVIDE |
| | ELEVATION CERTIFICATE. |
| | NOTE: LOWEST FLOOR ELEVATION TO BE NO |
| | LESS THAN 18" ABOVE THE CROWN OF |
| | THE ROAD. SECTION 3107.1.1 OF |
| | CITY AMENDMENTS TO SBC 1997. |
| | 2-REVISE/UPDATE ALL DRAWINGS SHOWING THE |
| | CALCULATIONS FOR THE DESIGN PRESSURES |
| | AT ALL EXTERIOR OPENINGS AS CALCULATED |
| | BY THE ENGINEER OF RECORD. ALSO, SEE |
| | OTHER COMMENTS ON PLANS. |
| | -CLEARLY WRITE NAME, ADDRESS, PHONE # |
| | AND LICENSE # OF ENGINEER IN DRAWINGS. |
| | 3-CLEARLY SPECIFY CEILING CONSTRUCTION |
| | AT FRONT AND BACK PORCHES. INCLUDING |
| | FASTENER TYPE AND SPACING. SECTION |
| | 2504 SBC 1997. |
| | 4-PRODUCT APPROVALS: |
| | -PROVIDE PRODUCT APPROVAL FOR DOUBLE |
| | ENTRY DOORS -AS SHOWN ON PLANS, AND |
| | WINDOW MULLIONS WITH LEGIBLE DRAWINGS. |
| | 5-NORANDEX PRODUCT APPROVALS: |
| | -PROFESSIONAL ENGINEER OF RECORD TO |
| | WRITE SITE SPECIFIC LOCATION; SPECIFY |
| | WHICH PRODUCTS ARE TO BE USED IN THIS |
| | PROJECT; CLEARLY WRITE HIS NAME, |
| | ADDRESS, OFFICE PHONE NUMBER, LICENSE |
| | NUMBER AND DATE DOCUMENT AT TIME OF |
| | SEALING IT. |
| | -NOTE: NEED COPIES OF TESTS RESULTS FOR |
| | SLIDING GLASS DOORS AS PER ASTM |
| | E-330. (SEC. 1706 SBC 1997). |
| | 6-STORM PANELS: |
| | -PROVIDE A COMPLETE INSTALLATION SCHED. |
| | AND KEY PLAN THAT MATCH ARCHITECT'S |
| | DRAWINGS. |
| | -CLEARLY INDICATE MOUNTING METHOD TO BE |
| | USED AND ANCHOR TYPE AND SPACING TO BE |
| | USED ACCORDING TO THE DESIGN PRESSURE, |
| | MEAN ROOF HEIGHT (15'-6" PLUS/MINUS), |
| | STORM PANEL SPAN, EDGE DISTANCE AND |
| | BUILDING CONSTRUCTION (MASONRY). |
| | 7-SOIL TEST REPORT NEEDS ORIGINAL |
| | SIGNATURE AND DATE WHEN DOCUMENT IS |
| | SEALED BY THE ENGINEER, |
| | 8-FOOTING SIZE RECOMMENDATIONS ON SOIL |
| | TEST REPORT DIFFER FROM FOOTING SIZE |
| | SPECIFIED ON FOUNDATION PLAN. REVISE |
| | AS REQUIRED. |