| Plan Review Stops For Permit 00031561 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-29 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-29 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-04-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-04-13 |
Time |
19:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-04-13 |
Time |
19:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-12-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-09 |
Time |
07:10 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-12-09 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-04-05 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-04-05 |
Time |
10:07 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-04-05 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-08-28 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-28 |
Time |
07:06 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-08-28 |
Time |
07:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2000-11-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-11-21 |
Time |
17:50 |
Rev Time |
0.33 |
| Received By |
jgomez |
Date |
2000-11-21 |
Time |
17:50 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | TRUSS DRAWINGS REVIEW. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2000-09-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-09-20 |
Time |
18:19 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2000-09-20 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | | | | 1-ITEMS REQUESTED ON PROVISO DATED | | | 8-25-00 WERE APPROVED EXCEPT FOR ITEM | | | #4. PRODUCT APPROVAL FOR ENTRY DOOR | | | SUBMITTED IS FOR SINGLE DOOR ONLY. | | | ARCHITECT'S DRAWINGS SHOW SINGLE DOOR | | | WITH SIDELITE ASSEMBLY. RESUBMIT. | | | -ARCHITECT TO PROVIDE BUCK DETAIL FOR | | | 2X BUCK INSTALLATION. SEE SHEET A-4, | | | CLARIFY HOW CAN YOU ATTACH A 2X4 BUCK | | | TO THE STRUCTURE WITH 1-1/2"LONG | | | NAILS. REVISE DETAIL AS REQUIRED. | | | | | | | | | | | | | | | | | | | | | NOTE: | | | -IF YOU HAVE ANY QUESTIONS, PLEASE FEEL | | | FREE TO CALL JULIO GOMEZ AT 659-8096 | | | EXT. 8232. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2000-08-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-08-25 |
Time |
17:02 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2000-08-25 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE "AO". WILL NEED TO PROVIDE | | | AN ELEVATION CERTIFICATE. | | | 2-REVISE AGAIN THE ATTIC ACCESS PANEL | | | SIZE. MINIMUM SIZE IS 22"X36" AS PER | | | SECTION 2309.6 SBC 1997. | | | 3-UPDATE/REVISE DRAWINGS AS REQUIRED: | | | -PROVIDE REAR ELEVATION AND FLOOR PLAN | | | THAT MATCH TABLE 600 CALCULATIONS. | | | REAR ELEVATION ON SHEET A-3 AND FLOOR | | | PLAN ON SHEET A-8 DON'T MATCH. ALSO, | | | REVISE SIZE OF SLIDING GLASS DOORS ON | | | SHEET A-8 PARTIAL FLOOR PLAN. | | | 4-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOOR WITH SIDELITE, BUT PLEASE MAKE | | | SURE DRAWINGS ARE LEGIBLE TO AVOID | | | UNNECESSARY RETURNS. | | | 5-SLIDING GLASS DOORS BY NORANDEX: | | | PROVIDE COPIES OF TESTS RESULTS DONE | | | AS PER ASTM E-330. | | | SECTION 1706 SBC 1997. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2000-05-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-05-24 |
Time |
21:41 |
Rev Time |
0.25 |
| Received By |
jgomez |
Date |
2000-05-24 |
Time |
21:41 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | COMMENTS FROM PREVIOUS CHECKLIST WERE | | | NOT ADDRESSED. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-05-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-05-17 |
Time |
16:56 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2000-05-17 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | 1-EGRESS WINDOW IN BEDROOM #2 DOESN'T | | | COMPLY WITH SECTION 1005.4 SBC 1997. | | | 2-OPENINGS AT REAR ELEVATION EXCEED THE | | | PERCENTAGE ALLOWED BY TABLE 600 SBC/97 | | | CALCULATIONS ON SHEET A-8 ARE MISSING | | | THE SH H36 WINDOW BY BREAKFAST AREA. | | | ALSO, SEE WINDOW AND DOOR PRODUCT | | | APPROVAL FOR ACTUAL OPENING REQUIRED. | | | THOSE ARE THE RIGHT NUMBERS TO USE FOR | | | OPENING CALCULATIONS. | | | 3-UPDATE/REVISE ALL DRAWINGS AS REQUIRED | | | SEE COMMENTS ON PLANS.USE SBC 97 NO 99 | | | 4-ATTIC ACCESS TO BE 22"X36" MINIMUM. | | | SECTION 2309.6 SBC 1997. | | | 5-PRODUCT APPROVALS: | | | -PROVIDE COPIES OF TEST RESULTS FOR | | | SLIDING GLASS DOORS AS PER ASTM E 330. | | | SECTION 1706 SBC 1997. | | | -DRAWINGS FOR OUTSWING ENTRY DOOR WITH | | | LITES PRODUCT APPROVAL ARE NOT LEGIBLE | | | 6-STORM PANELS: | | | -REVISE KEY PLAN AND INSTALLATION SCHED | | | TO MATCH ARCHITECT'S PLAN SHEET A-8. | | | NOTE: WAIT TILL ARCHITECT REVISES PLAN | | | TO MEET THE TABLE 600 REQUIREMENTS. | | | -USE MASONRY ANCHOR SPACING WHEN PANELS | | | ARE TO BE ATTACHED TO MASONRY COLUMNS | | | WITH FILLED CELLS. | | | 7-FLOOD ZONE "A0". WILL NEED TO PROVIDE | | | ELEVATION CERTIFICATE. | | | 8-OWES ADDITIONAL MONEY FOR BUILDING | | | VALUATION AND RADON FEES. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-03-30 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-03-30 |
Time |
15:56 |
Rev Time |
0.10 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|