Plan Review Details - Permit 00031559
| Plan Review Stops For Permit 00031559 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-29 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-29 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-04-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-04-13 |
Time |
20:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-04-13 |
Time |
20:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-04-05 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-04-05 |
Time |
10:32 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-04-05 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-08-28 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-28 |
Time |
07:30 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-08-28 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-03-31 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-03-31 |
Time |
18:58 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-03-31 |
Time |
18:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2000-09-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-09-20 |
Time |
19:56 |
Rev Time |
0.30 |
| Received By |
jgomez |
Date |
2000-09-20 |
Time |
19:56 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | | | | 1-ITEMS REQUESTED ON PROVISO DATED | | | 8-25-00 WERE APPROVED EXCEPT FOR ITEM | | | #4. PRODUCT APPROVAL FOR ENTRY DOOR | | | SUBMITTED IS FOR SINGLE DOOR ONLY. | | | ARCHITECT'S DRAWINGS SHOW SINGLE DOOR | | | WITH SIDELITE ASSEMBLY. RESUBMIT. | | | | | | -ARCHITECT TO PROVIDE BUCK DETAIL FOR | | | 2X BUCK INSTALLATION. SEE SHEET A-4, | | | CLARIFY HOW CAN A 2X4 WOOD BUCK BE | | | ATTACHED TO THE STRUCTURE WITH 1-1/2" | | | LONG NAILS. REVISE DETAIL AS REQUIRED. | | | | | | | | | | | | NOTE: | | | | | | -IF YOU HAVE ANY QUESTIONS, PLEASE FEEL | | | FREE TO CALL JULIO GOMEZ AT 659-8096 | | | EXT. 8232. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2000-08-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-08-25 |
Time |
11:14 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2000-08-25 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE "AO". WILL NEED TO PROVIDE | | | AN ELEVATION CERTIFICATE. | | | 2-REVISE AGAIN THE ATTIC ACCESS PANEL | | | SIZE. MINIMUM SIZE IS 22"X36" AS PER | | | SECTION 2309.6 SBC 1997. | | | 3-UPDATE/REVISE DRAWINGS AS REQUIRED: | | | -PROVIDE REAR ELEVATION AND FLOOR PLAN | | | THAT MATCH TABLE 600 CALCULATIONS. | | | 4-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOORWITH SIDELITE AND PLEASE MAKE | | | SURE DRAWINGS ARE LEGIBLE. | | | 5-SLIDING GLASS DOORS BY NORANDEX: | | | PROVIDE COPIES OF TESTS RESULTS DONE | | | AS PER ASTM E-330. | | | SECTION 1706 SBC 1997. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2000-05-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-05-24 |
Time |
21:39 |
Rev Time |
0.25 |
| Received By |
jgomez |
Date |
2000-05-24 |
Time |
21:39 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | 1-COMMENTS FROM PREVIOUS CHECKLIST WERE | | | NOT ADDRESSED. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-05-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-05-17 |
Time |
14:42 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2000-05-17 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | 1-EGRESS WINDOWS IN BEDROOM #2 DON'T | | | COMPLY WITH SECTION 1005.4 SBC 1997. | | | 2-OPENINGS AT REAR ELEVATION EXCEED THE | | | PERCENTAGE ALLOWED BY TABLE 600 SBC/97 | | | CALCULATIONS SHOWN ON SHEET A-8 ARE | | | MISSING THE SH H36 BY BREAKFAST AREA. | | | ALSO, SEE WINDOWS AND DOORS PRODUCT | | | APPROVAL FOR ACTUAL OPENING REQUIRED. | | | THESE ARE THE RIGHT NUMBERS TO USE FOR | | | OPENINGS CALCULATIONS. | | | 3-UPDATE/REVISE ALL DRAWINGS AS REQUIRED | | | SEE COMMENTS ON PLANS.USE SBC 97 NO 99 | | | 4-ATTIC ACCESS TO BE 22"X36" MINIMUM. | | | SECTION 2309.6 SBC 1997. | | | 5-PRODUCT APPROVALS: | | | -PROVIDE COPIES OF TEST RESULTS FOR | | | SLIDING GLASS DOORS AS PER ASTM E 330 | | | -DRAWINGS FOR OUTSWING ENTRY DOOR WITH | | | LITES PRODUCT APPROVAL ARE NOT LEGIBLE | | | 6-STORM PANELS: | | | -REVISE KEY PLAN AND INSTALLATION SCHED | | | TO MACTH ARCHITECT'S PLANS. SHEET A-8. | | | NOTE: WAIT TILL ARCHITECT REVISES PLAN | | | TO MEET THE TABLE 600 REQUIREMENTS. | | | -USE MASONRY ANCHOR SPACING WHEN PANELS | | | ARE TO BE ATTACHED TO MASONRY WITH | | | FILLED CELLS. | | | 7-FLOOD ZONE "AO". WILL NEED TO PROVIDE | | | ELEVATION CERTIFICATE. | | | 8-OWES $1235.01 FOR BUILDING VALUATION | | | AND RADON FEES. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-03-30 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-03-30 |
Time |
16:32 |
Rev Time |
0.10 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|