Plan Review Details - Permit 00031559
Plan Review Stops For Permit 00031559
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-08-29 Cont ID  
Sent By dpalmer Date 2000-08-29 Time 12:45 Rev Time 0.00
Received By dpalmer Date 2000-08-29 Time 12:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-04-13 Cont ID  
Sent By dpalmer Date 2000-04-13 Time 20:00 Rev Time 0.00
Received By dpalmer Date 2000-04-13 Time 20:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-04-05 Cont ID  
Sent By cthirben Date 2000-04-05 Time 10:32 Rev Time 1.00
Received By cthirben Date 2000-04-05 Time 10:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-08-28 Cont ID  
Sent By tlarge Date 2000-08-28 Time 07:30 Rev Time 0.33
Received By tlarge Date 2000-08-28 Time 07:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-03-31 Cont ID  
Sent By tlarge Date 2000-03-31 Time 18:58 Rev Time 0.33
Received By tlarge Date 2000-03-31 Time 18:58 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2000-09-20 Cont ID  
Sent By jgomez Date 2000-09-20 Time 19:56 Rev Time 0.30
Received By jgomez Date 2000-09-20 Time 19:56 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
  
 1-ITEMS REQUESTED ON PROVISO DATED
 8-25-00 WERE APPROVED EXCEPT FOR ITEM
 #4. PRODUCT APPROVAL FOR ENTRY DOOR
 SUBMITTED IS FOR SINGLE DOOR ONLY.
 ARCHITECT'S DRAWINGS SHOW SINGLE DOOR
 WITH SIDELITE ASSEMBLY. RESUBMIT.
  
 -ARCHITECT TO PROVIDE BUCK DETAIL FOR
 2X BUCK INSTALLATION. SEE SHEET A-4,
 CLARIFY HOW CAN A 2X4 WOOD BUCK BE
 ATTACHED TO THE STRUCTURE WITH 1-1/2"
 LONG NAILS. REVISE DETAIL AS REQUIRED.
  
  
  
 NOTE:
  
 -IF YOU HAVE ANY QUESTIONS, PLEASE FEEL
 FREE TO CALL JULIO GOMEZ AT 659-8096
 EXT. 8232.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-08-25 Cont ID  
Sent By jgomez Date 2000-08-25 Time 11:14 Rev Time 1.00
Received By jgomez Date 2000-08-25 Time 11:13 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "AO". WILL NEED TO PROVIDE
 AN ELEVATION CERTIFICATE.
 2-REVISE AGAIN THE ATTIC ACCESS PANEL
 SIZE. MINIMUM SIZE IS 22"X36" AS PER
 SECTION 2309.6 SBC 1997.
 3-UPDATE/REVISE DRAWINGS AS REQUIRED:
 -PROVIDE REAR ELEVATION AND FLOOR PLAN
 THAT MATCH TABLE 600 CALCULATIONS.
 4-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOORWITH SIDELITE AND PLEASE MAKE
 SURE DRAWINGS ARE LEGIBLE.
 5-SLIDING GLASS DOORS BY NORANDEX:
 PROVIDE COPIES OF TESTS RESULTS DONE
 AS PER ASTM E-330.
 SECTION 1706 SBC 1997.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-05-24 Cont ID  
Sent By jgomez Date 2000-05-24 Time 21:39 Rev Time 0.25
Received By jgomez Date 2000-05-24 Time 21:39 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-COMMENTS FROM PREVIOUS CHECKLIST WERE
 NOT ADDRESSED.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-05-17 Cont ID  
Sent By jgomez Date 2000-05-17 Time 14:42 Rev Time 1.50
Received By jgomez Date 2000-05-17 Time 14:42 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-EGRESS WINDOWS IN BEDROOM #2 DON'T
 COMPLY WITH SECTION 1005.4 SBC 1997.
 2-OPENINGS AT REAR ELEVATION EXCEED THE
 PERCENTAGE ALLOWED BY TABLE 600 SBC/97
 CALCULATIONS SHOWN ON SHEET A-8 ARE
 MISSING THE SH H36 BY BREAKFAST AREA.
 ALSO, SEE WINDOWS AND DOORS PRODUCT
 APPROVAL FOR ACTUAL OPENING REQUIRED.
 THESE ARE THE RIGHT NUMBERS TO USE FOR
 OPENINGS CALCULATIONS.
 3-UPDATE/REVISE ALL DRAWINGS AS REQUIRED
 SEE COMMENTS ON PLANS.USE SBC 97 NO 99
 4-ATTIC ACCESS TO BE 22"X36" MINIMUM.
 SECTION 2309.6 SBC 1997.
 5-PRODUCT APPROVALS:
 -PROVIDE COPIES OF TEST RESULTS FOR
 SLIDING GLASS DOORS AS PER ASTM E 330
 -DRAWINGS FOR OUTSWING ENTRY DOOR WITH
 LITES PRODUCT APPROVAL ARE NOT LEGIBLE
 6-STORM PANELS:
 -REVISE KEY PLAN AND INSTALLATION SCHED
 TO MACTH ARCHITECT'S PLANS. SHEET A-8.
 NOTE: WAIT TILL ARCHITECT REVISES PLAN
 TO MEET THE TABLE 600 REQUIREMENTS.
 -USE MASONRY ANCHOR SPACING WHEN PANELS
 ARE TO BE ATTACHED TO MASONRY WITH
 FILLED CELLS.
 7-FLOOD ZONE "AO". WILL NEED TO PROVIDE
 ELEVATION CERTIFICATE.
 8-OWES $1235.01 FOR BUILDING VALUATION
 AND RADON FEES.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-03-30 Cont ID  
Sent By gjoyce Date 2000-03-30 Time 16:32 Rev Time 0.10
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***