Plan Review Details - Permit 00031481
Plan Review Stops For Permit 00031481
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-05-11 Cont ID  
Sent By hpiskura Date 2000-05-11 Time 13:04 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-04-19 Cont ID  
Sent By bstaples Date 2000-04-19 Time 11:17 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00ENGINEER TO SIGN AND SEAL ENERGY SHEETS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-05-04 Cont ID  
Sent By dpalmer Date 2000-05-04 Time 06:47 Rev Time 0.00
Received By dpalmer Date 2000-05-04 Time 06:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-04-17 Cont ID  
Sent By dpalmer Date 2000-04-17 Time 19:12 Rev Time 0.00
Received By dpalmer Date 2000-04-05 Time 19:12 Sent To  
Notes
2001-01-08 00:00:00***************8 UNSAT ****************
  
 1)NOTE: NEED TO SUBMIT AIC RATING OF
 MAINS! 110-9/215-5 MAINS ARE TO BE RATED
 FOR THE AVAILABLE FAULT CURRENT.
  
 2)NOTE: PLEASE SUBMIT PLANS SHOWING THE
 GFI PROTECTION REQ`ED BY 230-95
 PLEASE INDICATE VOLTAGE ON SERVICE.
 215-5
 3)NOTE: PLEASE SHOW WIRE SIZES BEING
 INSTALLED OR NOTE IF THEY ARE BEING IN-
 STALLED AT LATER DATE.
  
 PLEASE NOTE THAT ALL REVISIONS THAT ARE
 BROUGHT IN ARE TO BE CLOUDED OR TRIANGL-
 ES. REVISIONS ARE TO BE ATTACHED TO ALL
 PLANS THAT ARE ALREADY IN FOR REWIEW(BY
 THE CONTRACTOR) ALL OLD PAGES NEED TO
 COME OUT FOR NEW CLEAN SETS TO BE REVIEW
 -ED.
 PLEASE NOTE THAT THERE IS NOT ENOUGH
 INFORMATION FOR AN INTERIOR BUILD OUT
 REVIEW.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS PLEAS
 -E CALL 659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-06-01 Cont ID  
Sent By rturnque Date 2000-06-01 Time 10:16 Rev Time 0.30
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-04-14 Cont ID  
Sent By rturnque Date 2000-04-14 Time 10:03 Rev Time 0.30
Received By rturnque Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVIDE FIRE SPRINKLER DRAWINGS
  
 PROVIDE EXIT LIGHT AND EMERGENCY LIGHT
 ILLUMINATION DETAILS
  
 PROVIDE EXIT DETAILS

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-05-10 Cont ID  
Sent By ndenmark Date 2000-05-10 Time 06:54 Rev Time 0.33
Received By ndenmark Date 2000-05-10 Time 06:54 Sent To  
Notes
2001-01-08 00:00:00SHELL ONLY,ANY MECHANICAL NOT INCLUDED
 ON THIS PLAN TO BE SUBMITTED FOR REVIEW
 WITH INTERIOR BUILDOUT PERMIT APPLICA-
 TION

Review Stop M MECHANICAL (A/C)
Rev No 1 Status A Date 2000-05-10 Cont ID  
Sent By ndenmark Date 2000-04-12 Time 09:03 Rev Time 0.33
Received By ndenmark Date 2000-04-12 Time 09:03 Sent To  
Notes
2001-01-08 00:00:00ACCEPTED BY REVISION/INTERIOR SEPARATE
 INSUFFICIENT INFORMATION TO REVIEW;
 PROVIDE DETAILS ON INTERIOR BUILDOUT
 INCLUDING DUCTWORK, DUCT SMOKE DETECTORS
 AND FIRE DAMPERS.

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-05-10 Cont ID  
Sent By tlarge Date 2000-05-10 Time 16:22 Rev Time 0.65
Received By tlarge Date 2000-05-10 Time 16:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-05-09 Cont ID  
Sent By tlarge Date 2000-05-09 Time 17:54 Rev Time 1.00
Received By tlarge Date 2000-05-09 Time 17:54 Sent To  
Notes
2001-01-08 00:00:00SUBMIT A STORM WATER RISER THAT CLEARLY
 SHOWS THE ENTIRE STORM SYSTEM BEING
 INSTALLED AT THIS TIME.SHOW THE SQUARE
 FOOT AREA BEING DRAINED BY EACH DRAIN &
 NOTE ENTIRE SQUARE FOOT AREA OF ROOF.
 SYSTEM SHALL BE SIZED PER SPC TABLES
 1108.1,1108.2.
  
 OVERFLOW DRAINS SHALL BE SIZED PER SPC
 SEC.1109.3.
  
 WHERE DO ROOF DRAINS TERMINATE? DRAINS
 COLLECTING CONDENSATE SHALL NOT
 DISCHARGE OVER SIDEWALK.
  
 REVISE SHT.274U-1 TO REFLECT ALL CORRECT
 CHANGES TO PLAN.(SQ.FOOT AREA DRAINED BY
 ROOF DRAINS)

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-04-20 Cont ID  
Sent By tlarge Date 2000-04-20 Time 19:36 Rev Time 1.00
Received By tlarge Date 2000-04-20 Time 19:36 Sent To  
Notes
2001-01-08 00:00:00SUBMIT COMPLETE SANITARY AND WATER
 SUPPLY RISER DIAGRAMS FOR REVIEW FOR ALL
 CHANGES TO THE PLUMBING SYSTEM PER
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 SHT.274M-1-TERMINATION OF CONDENSATE
 DRAINS SHALL COMPLY W/COUNTYWIDE AMEND-
 MENTS TO SPC SEC.804.3.
  
 SUBMIT COPY OF JOB SPECS AS REFERENCED
 ON PLANS.COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.1.
  
 SHT.274U-1-PLANS SHOW 2 ROOF DRAINS
 DRAINING 18000 & 18750 SQ.FT.EACH AND
 ROOF AREA IS TOTAL OF 18000 SQ.FT.-
 CLARIFY.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-04-19 Cont ID  
Sent By gjoyce Date 2000-03-29 Time 16:18 Rev Time 0.15
Received By bstaples Date   Time   Sent To  
Notes
***NONE***