Plan Review Details - Permit 00031336
Plan Review Stops For Permit 00031336
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-04-12 Cont ID  
Sent By dpalmer Date 2000-04-12 Time 07:06 Rev Time 0.00
Received By dpalmer Date 2000-04-12 Time 07:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-03-30 Cont ID  
Sent By cthirben Date 2000-03-30 Time 09:49 Rev Time 1.00
Received By cthirben Date 2000-03-30 Time 09:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-05-15 Cont ID  
Sent By jgomez Date 2000-05-15 Time 10:43 Rev Time 0.00
Received By jgomez Date 2000-05-15 Time 10:43 Sent To  
Notes
2001-01-08 00:00:00APPROVED BY TIM LARGE 3-30-00. SEE
 APPLICATION AND PLANS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-06-14 Cont ID  
Sent By jgomez Date 2000-06-14 Time 18:07 Rev Time 1.30
Received By jgomez Date 2000-06-14 Time 18:07 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-STORM PANELS:
 -PROVIDE A COMPLETE INSTALLATION SCHED.
 AS PER CITY SAMPLE.
 NOTE: ANCHOR TYPE AND SPACING TO BE
 ACCORDING TO DESIGN PRESSURES, MEAN
 ROOF HEIGHT, STORM PANEL SPAN AND
 STRUCTURE TO BE ATTACHED TO.
 2-ROOF TRUSSES.
 -UPDATE ALL GENERAL DETAILS TO BE
 CONSISTENT WITH SBC 1997 OR ASCE 7-95.
 -DATE AND SIGNATURE OF ENGINEER SHALL
 BE AT THE TIME THE DOCUMENT IS SEALED.
 3-ARCHITECT'S DRAWINGS SHOW "INSWING"
 ENTRY DOORS PROVIDE PRODUCT APPROVAL
 THAT MATCHES THIS INSTALLATION.
 4-PROVIDE ATTIC ACCESS AT MAIN ROOF.
 SECTION 2309.6 SBC 1997.
 5-PROVIDE COMPLETE SPECIFICATIONS FOR
 CONSTRUCTION OF CEILING AT FRONT AND
 REAR PORCHES. SECTION 2504.2 SBC 1997.
  
  
 NOTE: ITEMS ABOVE WERE REQUESTED ON THE
 PROVISO DATED 5-14-00 AND WERE NOT
 DONE OR INCOMPLETE. PLEASE REVIEW
 COMMENTS AND IF THERE IS ANY
 QUESTION PLEASE CALL ME AT
 650-8096 X 8232 FOR CLARIFICATIONS

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-05-14 Cont ID  
Sent By jgomez Date 2000-05-14 Time 14:39 Rev Time 1.50
Received By jgomez Date 2000-05-14 Time 14:39 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE PRODUCT APPROVAL FOR: ENTRY
 DOORS (INSWING), FRENCH DOOR AT MASTER
 SUITE.
 2-PROVIDE ATTIC ACCESS AT MAIN ROOF.
 SECTION 2309.6 SBC 1997.
 3-UPDATE/REVISE PLANS AS REQUIRED. SEE
 COMMENTS ON PLANS.
 4-PROVIDE COMPLETE SPECIFICATIONS FOR
 CONSTRUCTION OF CEILING AT ENTRY AND
 REAR PORCHES. INCLUDE FASTENER TYPE
 AND SPACING. SECTION 2405.2 SBC 1997.
 5-ENGINEER WHO SIGNED AND SEALED THE
 DESIGN CERTIFICATION FOR BUILDING CODE
 COMPLIANCE FORM TO SIGN, SEAL AND DATE
 STRUCTURAL DRAWINGS AS WELL.
 6-ROOF TRUSSES:
 -MEAN ROOF HEIGHT IS 18"-6" PLUS OR
 MINUS. MEAN ROOF HEIGHT IS TAKEN FROM
 GRADE, NOT FROM FINISH FLOOR, TO THE
 AVERAGE POINT OF THE HIGHEST ROOF.
 -UPDATE AND SIGN, SEAL AND DATE ALL
 GENERAL DETAILS TO BE CONSISTENT WITH
 SBC 1997 OR ASCE 7-95.
 7-STORM PANELS:
 -PROVIDE A COMPLETE INSTALLATION SCHED.
 AS PER CITY COPY.
 -HIGHLIGHT SPECIFIC MOUNTING DETAILS
 AND ANCHOR AND SPACING TO BE USED.
 -CHECK THAT KEY PLAN MATCHES CURRENT
 ARCHITECT'S DRAWINGS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-03-28 Cont ID  
Sent By gjoyce Date 2000-03-28 Time 15:18 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***