Plan Review Details - Permit 00031240
Plan Review Stops For Permit 00031240
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-05-04 Cont ID  
Sent By dpalmer Date 2000-05-04 Time 07:02 Rev Time 0.00
Received By dpalmer Date 2000-05-04 Time 07:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-04-24 Cont ID  
Sent By cthirben Date 2000-04-24 Time 14:07 Rev Time 1.00
Received By cthirben Date 2000-04-24 Time 14:06 Sent To  
Notes
2001-01-08 00:00:00****************PROVISO*****************
 INDICATE DRYER VENT ON PLANS.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-04-24 Cont ID  
Sent By tlarge Date 2000-04-24 Time 06:50 Rev Time 0.33
Received By tlarge Date 2000-04-24 Time 06:50 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-10-21 Cont ID  
Sent By jgomez Date 2000-10-21 Time 14:21 Rev Time 0.25
Received By jgomez Date 2000-10-21 Time 14:21 Sent To  
Notes
2001-01-08 00:00:00PRODUCT APPROVAL FOR ENTRY DOOR.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-09-01 Cont ID  
Sent By jgomez Date 2000-09-01 Time 17:24 Rev Time 0.50
Received By jgomez Date 2000-09-01 Time 17:24 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-05-14 Cont ID  
Sent By jgomez Date 2000-05-14 Time 14:41 Rev Time 1.50
Received By jgomez Date 2000-05-16 Time 12:14 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "AO". PROVIDE ELEVATION
 CERTIFICATE AFTER SLAB IS POURED.
 2-PROVIDE PRODUCT APPROVAL FOR INSWING
 ENTRY DOOR WITH SIDELITE ASSEMBLY AS
 SHOWN ON ARCHITECT'S PLANS.
 3-ARCHITECT'S DRAWING D-2 SPECIFIES DADE
 COUNTY PRODUCT APPROVAL FOR SLIDING
 GLASS DOORS. INFORMATION SUBMITTED
 DOESN'T HAVE A STANDARD PRODUCT
 APPROVAL (AND PRODUCT APPROVAL THAT
 WAS SUBMITTED HAS THE SEAL & SIGNATURE
 OF ANOTHER ARCHITECT). REVISE DRAWING
 OR RESUBMIT DADE COUNTY PRODUCT
 APPROVAL.
  
 4-12" GLASS BLOCK SPECIFIED DOESN'T MEET
 THE ONE HOUR FIRE RATING. REVISE DWGS
  
 5-PROVIDE COMPLETE SPECIFICATIONS/DETAIL
 FOR CEILING CONSTRUCTION AT ENTRY AT
 PORCH. SECTION 2504 SBC 1997.
 6-CLEARLY INDICATE HOW ARE OPENINGS
 PREPARED TO RECEIVE STORM PANELS.
 CLEARLY SPECIFY CONSTRUCTION OF THE
 WINDOW SILL. THIS WILL DETERMINE THE
 ACTUAL ANCHOR SPACING REQUIRED FOR THE
 STORM PANELS. SEE PRODUCT APPROVAL.
 7-STORM PANELS:
 -CLEARLY INDICATE/SPECIFY ANCHOR SCHED.
 ACCORDING TO BUILDING STRUCTURE, STORM
 PANEL SPAN AND EDGE DISTANCE.
 NOTES:
 A-THIS BUILDING IS MASONRY CONSTRUCT'N
 CONCRETE VALUES MAY BE USED WHEN
 ATTACHING TO PRECAST LINTELS OR PRE-
 CAST OR POURED CONCRETE SILLS.
 OTHERWISE USE MASONRY VALUES AS PER
 PRODUCT APPROVAL.
 8-UPDATE/REVISE ALL DRAWINGS AS REQUIRED
 SEE COMMENTS ON PLANS.
  
  
 NOTE: STORM PANELS PRODUCT APPROVAL WILL
 EXPIRE SOON. 6-26-00. MAKE SURE
 TO OBTAIN UPDATED PRODUCT APPROVAL
 FOR FUTURE APPLICATIONS TO AVOID
 DELAYS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-05-17 Cont ID  
Sent By gjoyce Date 2000-03-23 Time 15:07 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00SURVEY DOES NOT SHOW PRIVACY WALL