Plan Review Details - Permit 00031238
Plan Review Stops For Permit 00031238
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-04-10 Cont ID  
Sent By dpalmer Date 2000-04-10 Time 20:31 Rev Time 0.00
Received By dpalmer Date 2000-04-10 Time 20:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-03-30 Cont ID  
Sent By cthirben Date 2000-03-30 Time 07:51 Rev Time 1.00
Received By cthirben Date 2000-03-30 Time 07:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-03-28 Cont ID  
Sent By tlarge Date 2000-03-28 Time 19:57 Rev Time 0.33
Received By tlarge Date 2000-03-28 Time 19:57 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-09-21 Cont ID  
Sent By jgomez Date 2000-09-21 Time 11:26 Rev Time 0.00
Received By jgomez Date 2000-09-21 Time 11:26 Sent To  
Notes
2001-01-08 00:00:00MOST OF THE ITEMS REQUESTED ON PROVISO
 DATED 5-15-00 WERE ADDRESSED EXCEPT
 FOR:
  
 1-ARCHITECT REVISED ENTRY DOOR, BUT
 PRODUCT APPROVAL FOR "OUTSWING" DOOR
 WITH SIDELITE ASSEMBLY WAS NOT
 SUBMITTED.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-05-15 Cont ID  
Sent By jgomez Date 2000-05-15 Time 17:15 Rev Time 1.50
Received By jgomez Date 2000-05-15 Time 17:15 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "AO". PROVIDE ELEVATION
 CERTIFICATE AFTER SLAB IS POURED.
 2-PROVIDE PRODUCT APPROVAL FOR "INSWING"
 ENTRY DOOR WITH SIDELITE ASSEMBLY AS
 SHOWN ON ARCHITECT'S PLANS.
 3-ARCHITECT'S DRAWING D-2 SPECIFIES
 DADE COUNTY PRODUCT APPROVAL FOR
 SLIDING GLASS DOORS. INFORMATION
 SUBMITTED DOESN'T HAVE AN STANDARD
 PRODUCT APPROVAL. REVISE DRAWING OR
 PROVIDE A DADE COUNTY PRODUCT APPROVAL
 4-12" GLASS BLOCK DOESN'T MEET THE ONE
 HOUR FIRE RATING. REVISE DRAWING.
 5-FOOTING F6 TO HAVE 16" MINIMUM DEPTH
 AS PER SECTION 1804.1.3 SBC/97 AND
 SECTION 1804.1.9 OF CITY AMENDMENTS.
 REVISE DRAWINGS AS REQUIRED.
 6-PROVIDE COMPLETE SPECIFICATIONS/DETAIL
 FOR CONSTRUCTION OF CEILING AT ENTRY
 AND REAR PORCHES. SEC 2504 SBC 1997.
 7-CLEARLY INDICATE HOW ARE OPENINGS
 PREPARED TO RECEIVE STORM PANELS.
 CLEARLY INDICATE CONSTRUCTION OF
 WINDOW SILL. THIS WILL DETERMINE THE
 ACTUAL SPACING REQUIRED FOR THE STORM
 PANELS. SEE PRODUCT APPROVAL.
 8-STORM PANELS:
 -CLEARLY INDICATE/SPECIFY ANCHOR SCHED.
 ACCORDING TO BUILDING CONSTRUCTION,
 STORM PANEL SPAN AND EDGE DISTANCE.
 NOTE: THIS BUILDING IS MASONRY CONSTR.
 USE CONCRETE VALUES WHEN ANCHORING TO
 PRECAST CONCRETE LINTELS AND SILL.
 OTHERWISE THE MASONRY VALUES APPLY.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-03-27 Cont ID  
Sent By gjoyce Date 2000-03-27 Time 13:20 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***