| Plan Review Stops For Permit 00031218 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-05-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-02 |
Time |
19:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-02 |
Time |
19:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-04-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-04-19 |
Time |
19:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-04-19 |
Time |
19:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT ALL THE INFORMATION AS ASKED FOR | | | ON THE FIRST SET OF NOTES! | | | ALSO SUBMIT COMPLETE SET OF PLANS??? | | | PLEASE ADD NEW SHEETS INTO THE ORIG.SET. | | | | | | IF THERE ARE ANY QUESTIONS ON THE NOTES, | | | PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-04-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-04-10 |
Time |
20:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-04-10 |
Time |
20:03 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE:PLEASE SHOW A/C UNITS ON ELECTRIC | | | -AL PLANS AND SHOW THE REQ`D DISCONNECTS | | | AND WP GFI OUTLET.440-11/210-63/215-5 | | | | | | 2)NOTE: SMOKE DETECTORS ARE REQ`D INSIDE | | | AND OUTSIDE ALL SLEEPING ROOMS AND ROOMS | | | THAT CAN BE CONVERTED TO SLEEPING ROOMS. | | | ALSO REQ`D IN COMMON AREA DOWN MULTI- | | | LEVEL DWELLINGS. YOU HAVE THE REQ`D ONE | | | FOR UPSTAIRS BUT NEED AN ADDITIONAL ONE | | | DOWNSTAIRS. THE ABOVE IS REQ`D BY NFPA- | | | 72 2-2.1.1.1 | | | | | | 3)NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS BEING GFI/GFI | | | PROTECTED. AS PER 210-8-A-6 | | | | | | 4)NOTE:YOU SHOW ON E-1 200AMP & 100 AMP | | | PANEL? THIS DOES NOT CORRELATE WITH E-3 | | | PLEASE CORRECT. 215-5 | | | | | | 5)NOTE;MISSING OUTLET IN 2` OF WALL IN | | | BEDROOM. DOWNSTAIRS. | | | | | | 6)NOTE;MISSING OUTLET IN BEDROOM 2` WALL | | | UPSTAIRS. 210-52 MASTER BDRM. | | | | | | 7)NOTE:E-3 SHOW METER CAN SIZE. | | | | | | 8)NOTE:AS REQ`D BY 250-50 OF THE NEC. | | | BLDG. STEEL MUST BE PART OF THE GROUNDIN | | | -G ELECTRODE SYSTEM. PLEASE SHOW | | | | | | 9)NOTE:PLEASE INCLUDE THE REQ`D DEDICATE | | | -D BATH(S) CIRCUT(S) PER 210-11-C-3. | | | PLEASE SHOW ON PANEL SCHEDULE(S) | | | | | | 10)NOTE:SHOW EACH PANEL LOAD CALCULATION | | | ALSO.215-5 | | | ALSO SHOW IF FEEDERS TO PANELS ARE SLAB. | | | | | | 11)NOTE: PLEASE SHOW THE AIC RATINGS OF | | | MAINS.110-9/215-5 MAINS MUST BE RATED | | | FOR THE AVAILABLE FAULT CURRENT. | | | AIC RATINGS CAN BE FIGURED FROM FAULT | | | CURRENT CALCULATIONS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-04-18 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-04-18 |
Time |
10:39 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-04-18 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-04-08 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-04-08 |
Time |
08:15 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-04-08 |
Time |
08:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-03-30 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-03-30 |
Time |
09:29 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-03-30 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | | | | ******************DENIED**************** | | | | | | 1. EXHAUST FANS TO BE INSTALLED IN BATH- | | | ROOMS, AND INDICATE WHERE IT'S | | | EXHAUSTED. TYPE SIZE AND MAKE. | | | | | | 2. DRYER VENT TO BE SHOWN, SIZE & LOCA- | | | TION OF VENT | | | | | | 3. SHOW CFM'S IN POOL ROOM / GUEST SUITE | | | ON ALL A/C DROPS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2000-10-13 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-13 |
Time |
14:45 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-10-13 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)SUBMIT ADDITIONAL INFORMATION FOR THE | | | AQUARIUM.(RE:MANUFACTURER'S LITERATURE, | | | SIZE AND TYPE OF BFP DEVICE,SIZE ALL | | | PIPING,ETC.) | | | | | | 2)SUBMIT CLEAR AND LEGIBLE PLANS FOR | | | REVIEW.COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 104.2.1. | | | | | | 3)PLANS SHALL BE SIGNED AND SEALED BY | | | DESIGN PROFESSIONAL OF RECORD PER | | | COUNTYWIDE AMENDMENTS 104.2.3. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2000-10-12 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-12 |
Time |
22:19 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-10-12 |
Time |
22:19 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ENTERED IN ERROR.10/12/00.TKL. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2000-10-11 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-11 |
Time |
17:27 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-10-11 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT 2 SETS OF SIGNED AND SEALED | | | DRAWINGS SHOWING REVISIONS.COUNTYWIDE | | | AMENDMENTS TO SPC 104.2.3. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLAN EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2000-06-29 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-29 |
Time |
07:09 |
Rev Time |
0.25 |
| Received By |
tlarge |
Date |
2000-06-29 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | REVISED SANITARY RISER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-04-17 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-04-17 |
Time |
16:06 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-04-17 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-03-28 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-03-28 |
Time |
19:27 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-03-28 |
Time |
19:27 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DRAINS FOR 2ND.FLOOR CANNOT DISCHARGE | | | INTO VENTS FOR 1ST.FLOOR PER SPC 901.2, | | | 904.1. | | | | | | CLEARLY SHOW PIPE SIZES FOR ALL STACKS | | | AND VENTS.COMPLY W/SPC SEC.714.2,920.2. | | | | | | NO MORE THAN 2 WATER CLOSETS PERMITTED | | | ON 3" BUILDING DRAIN PER TABLE 714.1 | | | FOOTNOTE #3. | | | | | | WATER CLOSETS AND FIXTURE BRANCHES NOT | | | PERMITTED ON WET VENTS PER COUNTYWIDE | | | AMENDMENTS TO SPC SEC.911.1.1. | | | | | | MAX.20 FIXTURE UNITS PERMITTED ON 3" | | | LINE AT 1/8" PER FT.PER SPC TABLE 714.1. | | | | | | FIXTURES MISSING ON 2ND.FLR.RISER. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-05-12 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-05-12 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-05-03 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-05-03 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | LETTER W/ PLANS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-03-27 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-03-23 |
Time |
15:27 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|