Plan Review Details - Permit 00031218
Plan Review Stops For Permit 00031218
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-05-02 Cont ID  
Sent By dpalmer Date 2000-05-02 Time 19:38 Rev Time 0.00
Received By dpalmer Date 2000-05-02 Time 19:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-04-19 Cont ID  
Sent By dpalmer Date 2000-04-19 Time 19:14 Rev Time 0.00
Received By dpalmer Date 2000-04-19 Time 19:14 Sent To  
Notes
2001-01-08 00:00:00SUBMIT ALL THE INFORMATION AS ASKED FOR
 ON THE FIRST SET OF NOTES!
 ALSO SUBMIT COMPLETE SET OF PLANS???
 PLEASE ADD NEW SHEETS INTO THE ORIG.SET.
  
 IF THERE ARE ANY QUESTIONS ON THE NOTES,
 PLEASE CALL 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-04-10 Cont ID  
Sent By dpalmer Date 2000-04-10 Time 20:03 Rev Time 0.00
Received By dpalmer Date 2000-04-10 Time 20:03 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT *****************
  
 1)NOTE:PLEASE SHOW A/C UNITS ON ELECTRIC
 -AL PLANS AND SHOW THE REQ`D DISCONNECTS
 AND WP GFI OUTLET.440-11/210-63/215-5
  
 2)NOTE: SMOKE DETECTORS ARE REQ`D INSIDE
 AND OUTSIDE ALL SLEEPING ROOMS AND ROOMS
 THAT CAN BE CONVERTED TO SLEEPING ROOMS.
 ALSO REQ`D IN COMMON AREA DOWN MULTI-
 LEVEL DWELLINGS. YOU HAVE THE REQ`D ONE
 FOR UPSTAIRS BUT NEED AN ADDITIONAL ONE
 DOWNSTAIRS. THE ABOVE IS REQ`D BY NFPA-
 72 2-2.1.1.1
  
 3)NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS BEING GFI/GFI
 PROTECTED. AS PER 210-8-A-6
  
 4)NOTE:YOU SHOW ON E-1 200AMP & 100 AMP
 PANEL? THIS DOES NOT CORRELATE WITH E-3
 PLEASE CORRECT. 215-5
  
 5)NOTE;MISSING OUTLET IN 2` OF WALL IN
 BEDROOM. DOWNSTAIRS.
  
 6)NOTE;MISSING OUTLET IN BEDROOM 2` WALL
 UPSTAIRS. 210-52 MASTER BDRM.
  
 7)NOTE:E-3 SHOW METER CAN SIZE.
  
 8)NOTE:AS REQ`D BY 250-50 OF THE NEC.
 BLDG. STEEL MUST BE PART OF THE GROUNDIN
 -G ELECTRODE SYSTEM. PLEASE SHOW
  
 9)NOTE:PLEASE INCLUDE THE REQ`D DEDICATE
 -D BATH(S) CIRCUT(S) PER 210-11-C-3.
 PLEASE SHOW ON PANEL SCHEDULE(S)
  
 10)NOTE:SHOW EACH PANEL LOAD CALCULATION
 ALSO.215-5
 ALSO SHOW IF FEEDERS TO PANELS ARE SLAB.
  
 11)NOTE: PLEASE SHOW THE AIC RATINGS OF
 MAINS.110-9/215-5 MAINS MUST BE RATED
 FOR THE AVAILABLE FAULT CURRENT.
 AIC RATINGS CAN BE FIGURED FROM FAULT
 CURRENT CALCULATIONS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-04-18 Cont ID  
Sent By cthirben Date 2000-04-18 Time 10:39 Rev Time 1.00
Received By cthirben Date 2000-04-18 Time 10:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-04-08 Cont ID  
Sent By cthirben Date 2000-04-08 Time 08:15 Rev Time 1.00
Received By cthirben Date 2000-04-08 Time 08:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-03-30 Cont ID  
Sent By cthirben Date 2000-03-30 Time 09:29 Rev Time 1.00
Received By cthirben Date 2000-03-30 Time 09:23 Sent To  
Notes
2001-01-08 00:00:00 
  
  
 ******************DENIED****************
  
 1. EXHAUST FANS TO BE INSTALLED IN BATH-
 ROOMS, AND INDICATE WHERE IT'S
 EXHAUSTED. TYPE SIZE AND MAKE.
  
 2. DRYER VENT TO BE SHOWN, SIZE & LOCA-
 TION OF VENT
  
 3. SHOW CFM'S IN POOL ROOM / GUEST SUITE
 ON ALL A/C DROPS.

Review Stop P PLUMBING
Rev No 6 Status F Date 2000-10-13 Cont ID  
Sent By tlarge Date 2000-10-13 Time 14:45 Rev Time 0.33
Received By tlarge Date 2000-10-13 Time 14:45 Sent To  
Notes
2001-01-08 00:00:001)SUBMIT ADDITIONAL INFORMATION FOR THE
 AQUARIUM.(RE:MANUFACTURER'S LITERATURE,
 SIZE AND TYPE OF BFP DEVICE,SIZE ALL
 PIPING,ETC.)
  
 2)SUBMIT CLEAR AND LEGIBLE PLANS FOR
 REVIEW.COUNTYWIDE AMENDMENTS TO SPC SEC.
 104.2.1.
  
 3)PLANS SHALL BE SIGNED AND SEALED BY
 DESIGN PROFESSIONAL OF RECORD PER
 COUNTYWIDE AMENDMENTS 104.2.3.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 5 Status P Date 2000-10-12 Cont ID  
Sent By tlarge Date 2000-10-12 Time 22:19 Rev Time 0.30
Received By tlarge Date 2000-10-12 Time 22:19 Sent To  
Notes
2001-01-08 00:00:00ENTERED IN ERROR.10/12/00.TKL.

Review Stop P PLUMBING
Rev No 4 Status F Date 2000-10-11 Cont ID  
Sent By tlarge Date 2000-10-11 Time 17:27 Rev Time 0.30
Received By tlarge Date 2000-10-11 Time 17:27 Sent To  
Notes
2001-01-08 00:00:00SUBMIT 2 SETS OF SIGNED AND SEALED
 DRAWINGS SHOWING REVISIONS.COUNTYWIDE
 AMENDMENTS TO SPC 104.2.3.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLAN EXAMINER.

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-06-29 Cont ID  
Sent By tlarge Date 2000-06-29 Time 07:09 Rev Time 0.25
Received By tlarge Date 2000-06-29 Time 07:09 Sent To  
Notes
2001-01-08 00:00:00REVISED SANITARY RISER.

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-04-17 Cont ID  
Sent By tlarge Date 2000-04-17 Time 16:06 Rev Time 0.50
Received By tlarge Date 2000-04-17 Time 16:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-03-28 Cont ID  
Sent By tlarge Date 2000-03-28 Time 19:27 Rev Time 0.50
Received By tlarge Date 2000-03-28 Time 19:27 Sent To  
Notes
2001-01-08 00:00:00DRAINS FOR 2ND.FLOOR CANNOT DISCHARGE
 INTO VENTS FOR 1ST.FLOOR PER SPC 901.2,
 904.1.
  
 CLEARLY SHOW PIPE SIZES FOR ALL STACKS
 AND VENTS.COMPLY W/SPC SEC.714.2,920.2.
  
 NO MORE THAN 2 WATER CLOSETS PERMITTED
 ON 3" BUILDING DRAIN PER TABLE 714.1
 FOOTNOTE #3.
  
 WATER CLOSETS AND FIXTURE BRANCHES NOT
 PERMITTED ON WET VENTS PER COUNTYWIDE
 AMENDMENTS TO SPC SEC.911.1.1.
  
 MAX.20 FIXTURE UNITS PERMITTED ON 3"
 LINE AT 1/8" PER FT.PER SPC TABLE 714.1.
  
 FIXTURES MISSING ON 2ND.FLR.RISER.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-05-12 Cont ID  
Sent By hpiskura Date 2000-05-12 Time 16:02 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-05-03 Cont ID  
Sent By hpiskura Date 2000-05-03 Time 07:44 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00LETTER W/ PLANS

Review Stop Z ZONING
Rev No 1 Status P Date 2000-03-27 Cont ID  
Sent By gjoyce Date 2000-03-23 Time 15:27 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***