| Plan Review Stops For Permit 00031205 |
| Review Stop |
|
|
| Rev No |
1 |
Status |
N |
Date |
2000-12-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-21 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-11-28 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-11-28 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2000-11-28 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-11-28 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-09-20 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
Z |
|
| Notes |
| 2001-01-08 00:00:00 | NEEDS IMPACT FEES & RADON PAID |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-11-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-20 |
Time |
19:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-20 |
Time |
19:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-09-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-13 |
Time |
20:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-13 |
Time |
20:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2000-12-12 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-12-12 |
Time |
06:55 |
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PASSED |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2000-04-27 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-04-27 |
Time |
15:40 |
Rev Time |
3.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PASSED | | | | | | METER SIZE: 1 1/2" | | | NSTALLED BY:CONTRACTOR | | | IRRIGATION METER:1" | | | INSTALLED BY:CONTRACTOR | | | PFL SIZE:0" | | | INSTALLED BY:CONTRACTOR | | | GRAVITY SEWER: 6" | | | INSTALLED BY:CONTRACTOR | | | SPECIAL COMMENTS: | | | | | | PASSED WITH PROVISOS: | | | STORMWATER: | | | CALCULATIONS SUBMITTED ON REPORT ALONG | | | WITH PLANS, OK PER JOSE DEL RIOS. | | | DRIVEWAY APPROACHES PER CITY OF WEST | | | PALM BEACH ALONG WITH COORDINATION WITH | | | PLEASE KEEP IN MIND THAT A PERMIT IS | | | REQUIRED TO PERFORM WORK ON EITHER OF | | | THESE ROW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-11-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-21 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-21 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2001-11-21 00:00:00 | CANOPY PLAN. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-04-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-04-04 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-04-04 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2000-11-15 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-11-15 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-11-15 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) WRONG LIFE SAFETY CODE NOTED ON PLAN | | | REVIEW COMMENTS BECAUSE OF TYPOGRAPHICAL | | | ERROR. SHOULD HAVE READ NFPA 101-LIFE | | | SAFETY CODE, 1985 EDITION. | | | 2) THE FLAME SPREAD CHARACTERISTICS FOR | | | THE CANOPY IS TO BE FURTHER DEFINED. | | | THE ONE PAGE INFORMATION SHEET WAS | | | LOCATED ATTACHED TO CANOPY PLANS COVER | | | SHEET. | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR THE INSTALLATION OF UNDERGROUND | | | FUEL TANKS. | | | | | | APPROVED PROVISO: | | | | | | PLANS REVIEWED BY CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-08-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-21 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-08-21 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) WRONG LIFE SAFETY CODE REFERENCED IN | | | DESIGN CODE BOX. SHOULD READ NFPA 101- | | | LIFE SAFETY CODE, 1985 INSTEAD OF NFPA | | | 101-LIFE SAFETY CODE, 1994. | | | 2) BUILDING ADDRESS NOT SHOWN ON | | | ELEVATION DRAWINGS. BUILDING ADDRESS | | | IS TO COMPLY WITH CITY CODE REQUIREMENTS | | | 3) SERVICE STATION IS TO COMPLY WITH | | | THE REQUIREMENTS OF NFPA 30A, THE | | | STANDARD FOR AUTOMOTIVE AND MARINE | | | SERVICE STATION CODE, AND UNIFORM FIRE | | | SAFETY RULES AND STANDARDS, CHAPTER | | | 4A-49. | | | 4) THE UNDERGROUND FUEL TANKS ARE TO | | | COMPLY WITH NFPA 30, THE STANDARD FOR | | | THE STORAGE AND HANDLING OF FLAMMABLE | | | AND COMBUSTIBLE LIQUIDS. | | | 5) PLEASE IDENTIFY TYPE SIGNAGE FOR | | | EMERGENCY SHUT OFFS FOR FUEL | | | DISPENSING EQUIPMENT. | | | 6) PLEASE INDICATE ON THE PLANS, THE | | | LENGTHS OF FUEL HOSES PLANNED FOR USE. | | | 7) PLEASE IDENTIFY THE LOCATIONS FOR | | | WARNING SIGNS AT THE FUEL DISPENSING | | | AREA. WHAT WORDING IS PLANNED FOR THESE | | | SIGNS. | | | 8) PLEASE INDICATE BREAKAWAY DEVICE | | | LOCATIONS. | | | 9) PLEASE INDICATE TYPES AND LOCATIONS | | | OF FIRE EXTINGUISHERS. | | | 10) PROVIDE LISTING INFORMATION ON | | | DEVICES PLANNED FOR USE AT FUEL | | | DISPENSING AREA. | | | 11) PLEASE PROVIDE INFORMATION ON | | | PROPANE STORAGE AREA. | | | 12) PLEASE PROVIDE FLAME SPREAD | | | CHARACTERISTICS ON CANOPY. | | | 13) GAS INSTALLATION TO COMPLY WITH | | | NFPA 54. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-12-04 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-12-04 |
Time |
15:27 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2000-12-04 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | SEPARATE PERMITS ARE REQUIRED FOR FUEL, | | | AND WALK IN COOLER AND FREEZER BOXES. | | | SUBMIT PLANS FOR THESE AT TIME OF MECH. | | | PERMIT APPLICATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-09-05 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-09-05 |
Time |
08:53 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-09-05 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************DENIED******************* | | | 1.PROVIDE INFORMATION ON OUTSIDE AIR PER | | | ASHRAE 62-89 | | | 2 PROVIDE AIR BALANCE CALCULATIONS SHOW- | | | ING COMPLIANCE WITH 1997 SMC 501.2 | | | 3.PROVIDE DETAIL ON ROOF CURB AND PENE- | | | TRATION | | | 4. NOTE: SEPARATE PERMITS REQUIRED FOR | | | WALK- IN COOLER/FREEZERS AND FUEL TANKS | | | AND RELATED PIPING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-03-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-12 |
Time |
17:19 |
Rev Time |
2.50 |
| Received By |
jleech |
Date |
2001-03-12 |
Time |
17:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-11-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-14 |
Time |
16:45 |
Rev Time |
1.50 |
| Received By |
jleech |
Date |
2000-11-14 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1.TIMOTHY LARGE'S NOTE 4 RELOCATE W.H. | | | TO FLOOR OR INSTALL A FIXED LADDER. | | | 6 1/2 FT OFF FLOOR IS NOT READILY | | | ACCESSIBLE. | | | 2.CONDENSATE FROM A/C AND COOLERS | | | CANNOT GO TO SANITARY SEWER SYSTEM. | | | CONDENSATE SHOULD GO TO STORM OR TO | | | A DRYWELL. | | | 3.IF NATURAL GAS IS NOT TO BE USED | | | REMOVE GAS PIPING DIAGRAM FROM | | | SHEET #27. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-08-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-26 |
Time |
08:04 |
Rev Time |
1.75 |
| Received By |
tlarge |
Date |
2000-08-26 |
Time |
06:19 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)CIVIL DRAWING #6-RELOCATE CLEANOUTS | | | IN STORM SEWER TO ALIGN WITH THE FLOW. | | | SPC SEC.307.5. | | | | | | 2)SHT.FM-1,P-1-MIN.SIZE OF BUILDING | | | SEWER SHALL BE 4" PER SPC SEC.714.1, | | | FOOTNOTE #2. | | | | | | 3)GREASE TRAP MIN.SIZE SHALL BE 750 GAL. | | | PER CITY OF WPB ORDINANCE.CANNOT BE | | | INSIDE FOOD PREP AREA.CONTACT R.COMPO | | | AT 561-835-7423.SUBMIT APPROVAL FORM | | | FROM UTILITIES. | | | | | | 4)WATER HEATERS SHALL BE READILY | | | ACCESSIBLE PER SPC SEC.501.7.SUPPLY | | | FIXED LADDER OR PLATFORM OR RELOCATE | | | W.H.TO FLOOR. | | | | | | 5)RECEPTORS RECEIVING DISCHARGE FROM | | | INDIRECT WASTES SHALL BE FLOOR SINKS,NOT | | | FLOOR DRAINS.SPC SEC.804.1,807.1. | | | | | | 6)WATER FILTER SYSTEM SHALL BE NSF | | | APPROVED PER SPC SEC.615.1. | | | | | | 7)TRAP PRIMERS FOR FLOOR DRAINS SHALL | | | COMPLY W/SPC SEC.409.4.1.1. | | | | | | 8)DIELECTRIC UNIONS NOT PERMITTED.USE | | | DIELECTRIC NIPPLES OR COUPLINGS.SPC | | | 309.3. | | | | | | 9)GREASY WASTE SYSTEM SHALL COMPLY W/ | | | SPC SEC.921 FOR COMBINATION WASTE AND | | | VENT. | | | | | | 10)SEE ATTACHED REQS.FOR GAS INSTALL- | | | ATION. | | | | | | 11)LOCATION AND INSTALLATION OF LP | | | SYSTEM SHALL COMPLY W/NFPA 58.SHOW SIZE | | | OF LP TANKS(CAPACITY),LOCATION TO | | | SOURCES OF IGNITION,BUILDING OPENINGS, | | | ETC.SEE NFPA 58,TABLE 3-2.2.2., | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2001-11-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-11-19 |
Time |
07:52 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-12-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-11-28 |
Time |
08:44 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|