Plan Review Details - Permit 00031097
Plan Review Stops For Permit 00031097
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-05-16 Cont ID  
Sent By dpalmer Date 2000-05-16 Time 16:38 Rev Time 0.00
Received By dpalmer Date 2000-05-16 Time 16:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-03-25 Cont ID  
Sent By dpalmer Date 2000-03-25 Time 08:23 Rev Time 0.00
Received By dpalmer Date 2000-03-25 Time 08:23 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ****************
  
 1)NOTE: NEED TO SUBMIT NEW LOAD CALCS.
 PER 220-3-C-1SHOW ALL OF EXISTING SERV-
 ICE SIZE.
 2)NOTE:AS PER 210-8-A-6 NEED TO INDICATE
 ALL OUTLETS SERVING KITCHEN COUNTER-
 SPACE AS BEING GFI/GFI PROTECTED.
  
 3)NOTE: AS PER 1996 NFPA-72 2-2.1.1.1
 SMOKE DETECTORS ARE REQ`D INSIDE AND OUT
 SIDE ALL SLEEPING ROOMS OF DWELLINGS OF
 NEW CONSTRUCTION.
  
 4)NOTE: 210-11-C-3 PLEASE LIST NEW BATH
 CIRCUT REQ`D ON PANEL SCHEDULE.
  
 5)NOTE:PLEASE SHOW NEW LOCATION OF NEW
 AHU. YOU SHOW NEW A/C COND.UNIT BUT NO
 AHU. IF IN ATTIC NEEDS LIGHT AND REC.
 210-70/21-63
  
 6)NOTE: YOU SHOW ATTIC ACCESS. AS PER
 210-70 NEED TO HAVE LIGHT ON A SWITCH.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-04-11 Cont ID  
Sent By cthirben Date 2000-04-11 Time 08:29 Rev Time 1.00
Received By cthirben Date 2000-04-11 Time 08:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-03-23 Cont ID  
Sent By cthirben Date 2000-03-23 Time 11:38 Rev Time 1.00
Received By cthirben Date 2000-03-23 Time 11:39 Sent To  
Notes
2001-01-08 00:00:00 
  
  
 ****************DENIED******************
  
 NO A/C OR MECHANICAL PLANS SUBMITTED
  
 CALLED ARCHITECH AT 747-2026 SPOKE
 TO ANGELA WHO SAID THE MECH. CONTRAC
 WILL SUBMIT A/C PLANS.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-04-21 Cont ID  
Sent By tlarge Date 2000-04-21 Time 07:29 Rev Time 0.30
Received By tlarge Date 2000-04-21 Time 07:29 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-05-24 Cont ID  
Sent By rmcdouga Date 2000-05-24 Time 09:38 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
  
 1)PROVIDE SOIL BEARING TEST RESULT PRIOR
 TO FIRST INSPECTION.
  
 2)PROVIDE 2 COPIES OF INSTALLATION
 SCHEDULE AND KEY PLAN FOR STORM PANELS,
 WITH SPECIFIC TYPE FASTENERS TO BE USED
 PRIOR TO INSTALLATION.
  
 3)PROVIDE 2 CURRENT COPIES OF SBCCI OR
 METRO-DADE PRODUCT APPROVALS FOR
 EXTERIOR OUTSWING FRENCH DOORS AND
 AWNING WINDOWS AS SHOWN ON PRINTS.
  
 4)PROVIDE PRODUCT APPROVALS FOR ROOF
 COVERING UNDER A SEPARATE PERMIT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-04-29 Cont ID  
Sent By rmcdouga Date 2000-04-29 Time 13:29 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)PROVIDE 2 CURRENT COPIES OF SIGNED AND
 SEALED SURVEY
  
 2)BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED,PALM BEACH CO. IMPACT FEES MUST
 BE PAID,PLANS STAMPED BY THEM AND THE
 RECEIPT ATTACHED TO THE PERMIT APP.
  
 3)PROVIDE 2 CURRENT COPIES OF ENERGY
 CODE CALCULATIONS INCLUDING MANUAL "J"
  
 4)PROVIDE 2 CURRENT COPIES OF SBCCI OR
 METRO-DADE PRODUCT APPROVALS FOR EXTER-
 IOR WINDOWS,DOORS AND STORM PANELS
  
 5)PROVIDE 2 COPIES OF INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC
 ANCHORS TO BE USED
  
 6)PROVIDE SOIL BEARING TEST REPORT PRIOR
 TO 1ST INSPECTION
  
 7)PROVIDE PRODUCT APPROVALS FOR ROOF
 COVERING UNDER SEPERATE PERMIT

Review Stop Z ZONING
Rev No 1 Status P Date 2000-03-21 Cont ID  
Sent By gjoyce Date 2000-03-21 Time 14:21 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***