Plan Review Details - Permit 00030999
Plan Review Stops For Permit 00030999
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2000-09-27 Cont ID  
Sent By drunnels Date 2000-09-27 Time 11:45 Rev Time 1.00
Received By drunnels Date 2000-09-27 Time 11:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2000-05-30 Cont ID  
Sent By bstaples Date 2000-05-30 Time 10:39 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00A. SPOKE TO CONTRACTOR 786-412-0688
 THE FOLLOWING ITEMS ARE REQUIRED.
 2. ALL EXTERIOR GLASZING IS BY CITYPLACE
 OK GLAZING INSTALLED BY CITYPLACE AND
 IS NOW IN PLACEOK 5/30/00 OWNER.
 3. FIRE SPRINKLER CONTRACTOR TO SUBMIT
 PERMIT.
 4. INFORMATION ON IMPACT GLAZING IS NOT
 SEE ABOVE OK 5/30/00
 SYSTEM IS TO BE CONSIDERED FOR USE.
 5. CONTRACTOR TO APPLY FOR PERMIT AND
 PAY ALL FEES DUE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2000-04-26 Cont ID  
Sent By bstaples Date 2000-04-26 Time 15:29 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:004/26/00
 1. FLORIDA ENERGY SHEETS
 2. LETTER FROM SPECIAL INSPECTOR
 RELEASING THE PERMIT.
 3. FP-1 & 2 NOT SIGNED AND SEALED.
 4. FIRE SPRINKLER PERMIT NOT APPLIED FOR
 5. CONTRACTOR TO MAKE APPLICATION FOR
 PERMIT AND PAY FEES DUE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-03-23 Cont ID  
Sent By bstaples Date 2000-03-23 Time 12:13 Rev Time 2.50
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00ANY EXTERIOR GLAZING INSTALLED SHALL BE
 IMPACT RESISTANT. SUBMIT PRODUCT
 APPROVAL INFORMATION PRIOR TO INSTALLING
  
 SIGNS ARE NOT COVERED BY THIS PERMIT.
  
 ESCULATOR OPEANING SHALL COMPLY WITH
 1997 SBC SECTION 705.2.2(8), A OR B.
  
 ALL WOOD SHALL BE PRESSURE TREATED FIRE
 RETARDANT LUMBER. SEE 1997 SBC TYPE II
 BUILDINGS SECTION 604.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-09-22 Cont ID  
Sent By dpalmer Date 2000-09-22 Time 12:58 Rev Time 0.00
Received By dpalmer Date 2000-09-22 Time 12:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-04-26 Cont ID  
Sent By dpalmer Date 2000-04-26 Time 11:30 Rev Time 0.00
Received By dpalmer Date 2000-04-26 Time 11:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-03-21 Cont ID  
Sent By dpalmer Date 2000-03-21 Time 14:54 Rev Time 0.00
Received By dpalmer Date 2000-03-21 Time 14:54 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE: PLEASE SUBMIT COMPLETE LOAD
 CALCULATIONS FOR MAIN AND EACH PANEL.
  
 2)NOTE: SUBMIT AIC RATINGS OF ALL MAINS
 AND RATINGS OF BRANCH BRKRS. PER 110-9
  
 3)NOTE; NEED TO SUBMIT LINE DIAGRAM OF
 SERVICE .TO INCLUDECONDUITS, WIRE SIZE
 COMPLETE GROUNDING SYSTEM.
  
 4)NOTE: SUBMIT PANEL SCHEDULES.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW AND APPROVAL.IF THERE ARE ANY
 QUESTIONS PLEASE CALL 659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-09-21 Cont ID  
Sent By mcarsill Date 2000-09-21 Time 10:38 Rev Time 0.00
Received By mcarsill Date 2000-09-21 Time 10:38 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-03-23 Cont ID  
Sent By bstaples Date 2000-03-23 Time 12:12 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00SEE REVIEW NOTES ATTACHED TO PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-09-27 Cont ID  
Sent By ndenmark Date 2000-09-27 Time 11:33 Rev Time 0.50
Received By ndenmark Date 2000-09-27 Time 11:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-03-23 Cont ID  
Sent By ndenmark Date 2000-03-23 Time 14:22 Rev Time 1.00
Received By ndenmark Date 2000-03-23 Time 14:22 Sent To  
Notes
2001-01-08 00:00:00SEE FIRE DEPT NOTES ON KITCHEN EQUIPMENT

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-09-22 Cont ID  
Sent By tlarge Date 2000-09-22 Time 18:24 Rev Time 1.50
Received By tlarge Date 2000-09-22 Time 17:39 Sent To  
Notes
2001-01-08 00:00:00********************PROVISO*************
 1)SHT.P-3-RESTROOM AND CAFE ISOMETRIC.-
 DESIGN OF THE SANITARY SYSTEM SHALL
 COMPLY W/SPC SEC.914.1,920.3 FOR CIRCUIT
 AND LOOP SYSTEM.
  
 2)WATER HEATER SHALL BE READILY
 ACCESSIBLE.SUPPLY SHIP'S LADDER AND
 PLATFORM OR RELOCATE WATER HEATER TO
 FLOOR.SPC SEC.501.7.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-04-25 Cont ID  
Sent By pschmitz Date 2000-04-25 Time 15:37 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-01-08 00:00:00REVISION REVIEWED AS / UPDATE 4-6-00
 FROM NOTES BY T/L 3-23-00.PES

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-03-23 Cont ID  
Sent By tlarge Date 2000-03-23 Time 06:38 Rev Time 6.00
Received By tlarge Date 2000-03-23 Time 06:38 Sent To  
Notes
2001-01-08 00:00:00SUBMIT REVISED OCCUPANT LOAD
 CALCULATIONS TO ENSURE COMPLIANCE W/SPC
 TABLE 407 FOR MIN.NUMBER OF REQD.
 SANITARY FACILITIES.(ADD'L.LAVS MAY BE
 REQD.)SPC SEC.407.1.3. IS SPECIFIC TO
 THE AREAS ALLOWED TO BE DEDUCTED.
  
 SHT.A-100-SHOW REQD.WHEELCHAIR TURNING
 SPACE IN THE TOILET ROOM AND RESTROOMS
 PER FACBC SEC.4.2.3.
  
 BREAKROOM SINK SHALL COMPLY W/FACBC SEC.
 4.24.1.-4.24.7.
  
 A FLOOR DRAIN IS REQD.IN THE 1ST FLR.
 TOILET ROOM PER SPC SEC.409.4.1.1.
  
 WALLS AND FLOOR IN FIRST FLOOR TOILET
 ROOM SHALL BE NONABSORBENT MATERIAL TO A
 HEIGHT OF 4'PER SPC SEC.1204.2.
  
 URINAL SHALL COMPLY W/FACBC SECS.4.18.1-
 4.18.4.
  
 SHT.A200-TOWEL DISPENSER W/O WASTE SHALL
 COMPLY W/FACBC SEC.4.2.5.,4.2.6 AND FIG.
 6.
  
 SHT.A200-THE LAVS IN THE HANDICAP TOILET
 STALLS SHALL COMPLY W/FACBC SEC.4.17.3.
 (CANNOT INFRINGE ON CLEAR FLOOR SPACE
 FOR WATER CLOSET.)
  
 WATER SOFTENER SHALL BE NSF APPROVED PER
 SPC SEC.615.
  
 SHT.A-220-CAFE EQUIP.SCHEDULE #27 NOTES
 GREASE TRAP IN FLOOR.GREASE TRAP CANNOT
 BE LOCATED IN FOOD PREP AREA PER BOARD
 OF HEALTH REQS.AND CITY ORDINANCE.
  
 SUBMIT WATER SUPPLY RISER PER COUNTYWIDE
 AMENDMENTS TO SPC SEC.104.2.1.
  
 RELIEF DRAINS SHALL DISCHARGE TO EXTER-
 IOR PER COUNTYWIDE AMENDMENTS TO SPC SEC
 507.6(3).
  
 SHT.P-3.1-1/2" VENT NOT PERMITTED ON
 GREASY WASTE PER TABLE 920.4.
  
 DESIGN OF CIRCUIT AND LOOP SYSTEM FOR
 RESTROOMS SHALL COMPLY W/SPC SEC.914.
  
 PLANS SHALL BE ROUTED TO DEPT. OF
 BUSINESS REGULATION FOR REVIEW PER
 COUNTYWIDE AMENDMENTS TO SPC SEC.101.4.7
  
  
  
 SUBMIT ENLARGED ARCH.PLAN VIEW AND
 PLUMBING PLAN VIEW FOR THE 1ST.FLR.
 TOILET ROOM PER COUNTYWIDE AMENDMENTS TO
 SPC SEC.104.2.1.