Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-05-16 Cont ID  
Sent By hpiskura Date 2000-05-16 Time 13:49 Rev Time 99.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-06-21 Cont ID  
Sent By dpalmer Date 2000-06-21 Time 09:00 Rev Time 0.00
Received By dpalmer Date 2000-06-21 Time 09:00 Sent To  
Notes
2001-01-08 00:00:00************* PROVISO ******************
  
  
 1)NOTE: SAME AS FIRST SET OF NOTES!!
 REVISE LOAD CALCULATIONS FOR EXISTING
 60AMP PANEL.
  
 PLEASE SUBMIT FOR REVIEW AND RECORD
 BEFORE FIRST ELECTRICAL INSPECTION IS
 CALLED IN. IF THERE ARE ANY QUESTIONS
 CALL 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-05-08 Cont ID  
Sent By dpalmer Date 2000-05-08 Time 19:17 Rev Time 0.00
Received By dpalmer Date 2000-05-08 Time 19:17 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT ****************
  
  
 1)NOTE:NEED TO RE-FIG LOAD CALCULATIONS
 PER ART 220-20 OF THE NEC. ALSO LIGHTING
 MUST BE SHOWN AT 125% AND THE LARGEST
 MOTOR LOAD. 125 % FOR CONTINUOUS LOADS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. THE PLANS WOULD HAVE PASSED WITH
 A PROVISO BUT WERE COMING BACK FOR
 PLUMB COMMENTS ANYWAY. IF THERE ARE ANY
 QUESTIONS PLEASE CALL 659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-05-12 Cont ID  
Sent By rturnque Date 2000-05-12 Time 14:04 Rev Time 0.15
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-05-09 Cont ID  
Sent By cthirben Date 2000-05-09 Time 07:20 Rev Time 0.50
Received By cthirben Date 2000-05-09 Time 07:19 Sent To  
Notes
2001-01-08 00:00:00****************NOTES*******************
 NO MECHANICAL PLANS SUBMITTED.

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-07-14 Cont ID  
Sent By fknapp Date 2000-07-14 Time 13:35 Rev Time 0.00
Received By fknapp Date   Time   Sent To  
Notes
2001-01-08 00:00:00OK PER T LARGE

Review Stop P PLUMBING
Rev No 3 Status F Date 2000-07-07 Cont ID  
Sent By tlarge Date 2000-07-07 Time 08:51 Rev Time 0.50
Received By tlarge Date 2000-07-07 Time 08:50 Sent To  
Notes
2001-01-08 00:00:00THESE PLANS SHALL BE CONSLOIDATED IN AN
 ORDERLY MANNER FOR PROPER REVIEW.THERE
 ARE SHEETS THAT STILL NOTE THE PLUMBING
 TO BE CONNECTED TO A SEPTIC SYSTEM,
 ANOTHER SHEET NOTES A CONNECTION TO
 SANITARY SYSTEM AND FORCE MAIN.
 VOID SHEETS NO LONGER APPLICABLE.SUBMIT
 ALL INFORMATION ON "NEW ADD-A-BATH PUMP
 STATION"-INCLUDE SANITARY ISOMETRIC.
 THE SUBMITTED ISOMETRIC IS STILL NOT TO
 CODE.SEE PREVIOUS PLUMBING COMMENTS.
  
 IF YOU HAVE ANY QUESTIONS I CAN BE
 REACHED AT 561-659-8096,EXT.8377.
 TIMOTHY LARGE,PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-06-22 Cont ID  
Sent By tlarge Date 2000-06-22 Time 07:45 Rev Time 0.33
Received By tlarge Date 2000-06-22 Time 07:45 Sent To  
Notes
2001-01-08 00:00:00PLANS SHALL BE REVIEWED AND APPROVED BY
 THE PALM BEACH COUNTY HEALTH DEPT.PRIOR
 TO REVIEW BY THIS DEPT.COUNTYWIDE AMEND-
 MENTS TO SPC SEC.101.4.7.
  
 VENT SHALL BE LOCATED BETWEEN THE FLOOR
 DRAINS.SPC SEC.901.2.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-05-05 Cont ID  
Sent By tlarge Date 2000-05-05 Time 18:23 Rev Time 0.65
Received By tlarge Date 2000-05-05 Time 18:23 Sent To  
Notes
2001-01-08 00:00:00PLANS SHALL BE ROUTED TO HEALTH DEPT.FOR
 REVIEW AND APPROVAL PRIOR TO REVIEW BY
 THIS DEPT.COUNTYWIDE AMENDMENTS TO SPC
 SEC.101.4.7.
  
 FLOOR DRAINS SHALL CONNECT TO THE
 SANITARY SYSTEM.SPC SEC.301.11.1.
  
 SUBMIT SANITARY AND WATER SUPPLY RISER
 FOR REVIEW.COUNYUWIDE AMENDMENTS TO SPC
 SEC.104.2.1.
  
 CONTACT DEPT.OF BUSINESS REGULATION FOR
 APPROVAL OF SNACK BAR PLANS AT:
 (954)958-5520.
  
 INDICATE ON PLANS LOCATION OF SANITARY
 FACILITIES FOR PATRONS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-05-02 Cont ID  
Sent By gjoyce Date 2000-03-17 Time 15:23 Rev Time 0.50
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00NEEDS MINOR AMENDMENT