Plan Review Details - Permit 00030426
Plan Review Stops For Permit 00030426
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-04-05 Cont ID  
Sent By dpalmer Date 2000-04-05 Time 22:27 Rev Time 0.00
Received By dpalmer Date 2000-04-05 Time 22:27 Sent To  
Notes
2001-01-08 00:00:00NOTES ON PLANS
 MISSING CWP FOR GROUNDING ELECTRODE
 MISSING HALL REC 210-52H
 MISSING REC 210-52

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-03-15 Cont ID  
Sent By cthirben Date 2000-03-15 Time 12:27 Rev Time 1.00
Received By cthirben Date 2000-03-15 Time 12:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-03-12 Cont ID  
Sent By tlarge Date 2000-03-12 Time 06:15 Rev Time 0.33
Received By tlarge Date 2000-03-12 Time 06:15 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-06-27 Cont ID  
Sent By jgomez Date 2000-06-27 Time 14:51 Rev Time 0.50
Received By jgomez Date 2000-06-27 Time 14:51 Sent To  
Notes
2001-01-08 00:00:00MOST OF THE ITEMS REQUESTED ON PROVISO
 WERE TAKEN CARE OF EXCEPT FOR:
 1-ENERGY CALCULATIONS WERE NOT REVISED.
 CEILING AREA TO BE INCREASED AS
 REQUIRED PER SECTION 602.1.ABC.1.2 OF
 FLORIDA ENERGY EFFICIENCY CODE FOR
 BUILDING CONSTRUCTION, 1997 EDITION.
 2-PROVIDE PRODUCT APPROVAL FOR EXTERIOR
 FRENCH DOOR AT MASTER SUITE.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-05-03 Cont ID  
Sent By jgomez Date 2000-05-03 Time 20:45 Rev Time 2.00
Received By jgomez Date 2000-05-03 Time 20:45 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "AO". PROVIDE ELEVATION
 CERTIFICATE.
 2-CLEARLY INDICATE WINDOWS TO HAVE
 SAFETY GLASS. SECTION 2405.2 SBC 1997.
 3-REVISE ENERGY CALCULATIONS:
 -FLOOR AREA UNDER ATTIC TO BE INCREASED
 AS REQUIRED. SEE SECTION 602.1.ABC.1.2
 FLORIDA ENERGY CODE, 1997 EDITION.
 4-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SIDELITE ASSEMBLY AND FOR
 EXTERIOR FRENCH DOOR AT MASTER SUITE.
 5-STORM PANELS:
 -CLARIFY WHY THE INSTALLATION SCHEDULE
 SPECIFIES ANCHOR SPACING TO BE 12" OC,
 WHILE, ANCHOR SCHEDULE ON SHEET 6 OF
 15 OF APPROVED DRAWINGS IS BEING
 HIGHLIGHTED DIFFERENTLY.
 -CLEARLY SPECIFY WHICH STORM PANELS ARE
 GOING TO BE INSTALLED IN CONCRETE AND
 WHICH ARE GOING TO BE INSTALLED ON
 MASONRY. NOTICE THE DIFFERENCE ON
 ANCHOR SPACING.
 6-REVISE/UPDATE ALL PLANS AS REQUIRED.
 SEE COMMENTS ON PLANS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-05-04 Cont ID  
Sent By jgomez Date 2000-05-04 Time 10:58 Rev Time 2.00
Received By jgomez Date 2000-05-04 Time 10:58 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "AO". PROVIDE ELEVATION
 CERTIFICATE.
 2-CLEARLY INDICATE WINDOWS TO HAVE
 SAFETY GLAZING AS PER SECTION 2405.2
 SBC 1997. SEE PLANS FOR COMMENTS.
 3-REVISE ENERGY CALCULATIONS TO REFLECT
 THE ACTUAL AREA UNDER THE ATTIC. SEE
 SECTION 602.1.ABC.1.2 FLORIDA ENERGY
 CODE, 1997 EDITION.
 4-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SIDELITE ASSEMBLY AND
 PRODUCT APPROVAL FOR EXTERIOR FRENCH
 DOOR IN MASTER SUITE.
 5-STORM PANELS:
 -CLARIFY WHY THE INSTALLATION SCHED.
 SPECIFIES ANCHOR SPACING TO BE 12" OC,
 WHILE ANCHOR SCHEDULE ON SHEET 6 OF 15
 OF APPROVED DRAWINGS IS HIGHLIGHTED
 DIFFERENTLY.
 -CLEARLY INDICATE WHICH STORM PANELS
 ARE GOING TO BE INSTALLED IN CONCRETE
 AND WHICH ONES ON MASONRY.
 6-REVISE/UPDATE ALL DRAWINGS AS REQUIRED
 SEE COMMENTS ON PLANS.