Plan Review Details - Permit 00021424
Plan Review Stops For Permit 00021424
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-11-06 Cont ID  
Sent By dpalmer Date 2000-11-06 Time 18:36 Rev Time 0.00
Received By dpalmer Date 2000-11-06 Time 18:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-03-20 Cont ID  
Sent By dpalmer Date 2000-03-20 Time 12:43 Rev Time 0.00
Received By dpalmer Date 2000-03-20 Time 12:43 Sent To  
Notes
2001-01-08 00:00:00*************** PROVISO ***************
  
 1)NOTE: NEED TO SHOW A/C EQUIPMENT AND
 ALL DISCONNECTS AND REQ`D RECEPTS.
  
 2)NOTE: MISSING OUTLET PER 210-52E
 INFRONT OF DWELLING.
  
 3)NOTE: MISSINGLIGHTS REQ`D FOR EGRESS
  
  
 4)NOTE: PLEASE LIST ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS BEING GFI/GFI
 PROTECTED.210-8-A-6
  
 5)NOTE: NEED TO SHOW ALL ELECTRICAL AS
 BEING UPDATED. MORE THAN 50% OF ELEC IS
 BEING DONE. PLEASE SHOW ALL ELEC. BEING
 DONE ANDE EXISTING ELECTRICAL.
  
 6)NOTE: MISSING OUTLETS REQ`D BY 210-52
 2`6`12` OF WALL.
  
 7)NOTE: SMOKE DETECTORS ARE REQ`D ALSO
 REQ`D OUTSIDE BEDROOMS.NFPA-72 2-2.1.1.1
 TO INCLUDE SITTING ROOM.
 8)NOTE: MISSING OUTLETS ON SECOND FLOOR
 210-52
  
 9)NOTE: NEED LIGHT FROM MASTER BEDROOM
 AS MEANS OF EGRESS. 210-70
  
 10)NOTE: PLEASE SHOW THE REQ`D BATH(S)
 CIRCUT(S) PER 210-52D/210-11-C-3
 PLEASE LIST ON PANEL SCHEDULE(S)
  
 ALSO PLEASE HAVE PANEL SCHEDULES AND
 SERVICE SHOWN ON SHEETS WITH FRIST AND
 SECOND FLOOR ELECTRIC.
  
 PLEASE HAVE ALL THE ABOVE SUBMITTTED FOR
 REVIEW AND APPROVAL BEFORE ANY ROUGH
 ELECTRICAL INSPECTION IS CALLED IN.
 IF THERE ARE ANY QUESTIONS PLEASE CALL
 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-03-15 Cont ID  
Sent By cthirben Date 2000-03-15 Time 14:39 Rev Time 1.00
Received By cthirben Date 2000-03-15 Time 14:32 Sent To  
Notes
2001-01-08 00:00:00****************PROVISO*****************
 REQUIRE EXHAUST FANS IN BATHROOMS::RANGE
 AND DRYER TO BE VENTED TO THE OUTSIDE.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-03-12 Cont ID  
Sent By tlarge Date 2000-03-12 Time 06:29 Rev Time 0.50
Received By tlarge Date 2000-03-12 Time 06:28 Sent To  
Notes
2001-01-08 00:00:00SUBMIT SANITARY RISER FOR KITCHEN PRIOR
 TO ROUGH PLUMBING INSPECTION.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-06-02 Cont ID  
Sent By fknapp Date 2000-06-02 Time 11:55 Rev Time 2.00
Received By fknapp Date 2000-06-02 Time 11:54 Sent To  
Notes
2001-01-08 00:00:00 
  
 ****************PROVISO*****************
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR ALL EXTERIOR DOORS AND WINDOWS TO
 BE USED.
  
 2)PROVIDE PRODUCT APPROVAL FOR ROOF
 COVERING UNDER SEPERATE PERMIT.
  
 3)PROVIDE DETAILS FOR FRAMING OVER
 WINDOWS ON 2ND FLOOR.
  
 4)PROVIDE STORM PANEL DRAWINGS WITH
 SIGNATURE AND SEAL OF REQ. ENGINEER
 AND INSTALLATION SCHEDULE AND KEY PLAN
 WITH SPECIFIC ANCHORS AND MOUNTING TO
 BE USED.
  
 PLEASE SUBMIT PRIOR TO INSTALLATION.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-04-01 Cont ID  
Sent By fknapp Date 2000-04-01 Time 16:13 Rev Time 4.00
Received By fknapp Date 2000-04-01 Time 12:29 Sent To  
Notes
2001-01-08 00:00:00 
  
 ****************DENIED******************
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COPIES OF SBCCI OR
 METRO DADE PRODUCT APPROVALS FOR ALL
 EXTERIOR DOORS AND WINDOWS.
  
 2)PROVIDE PRODUCT APPROVAL FOR ROOF
 COVERING UNDER SEPERATE PERMIT.
  
 3)PROVIDE MISSILE IMPACT PROTECTION
 INFORMATION.
  
 4)PROVIDE SIGNATURE OF OWNER/AGENT ON
 ENERGY CALCULATIONS.
  
 5)PROVIDE CONSTRUCTION DETAILS FOR
 CHIMNEY AND MANUFACTURE'S SPECIFICATIONS
 AND ELEVATION THAT COMPLIES WITH
 1997 SBC 2804
  
 6)PROVIDE UPLIFT CALCULATIONS FOR TRUSS
 FRAMING WITH SPECIFIC CONNECTORS TO BE
 USED.
  
 7)IDENTIFY ALL CONNECTORS FOR ALL
 FRAMING.
  
 8)PROVIDE ACTUAL DESIGN PRESSURES FOR
 ALL EXTERIOR DOORS AND WINDOWS ON PLANS.
  
 9)PROVIDE PORCH RAILING DETAILS.
  
 10)PROVIDE STAIR DETAILS WITH HANDRAIL
 AND GUARDRAIL DIMENSIONS.
  
 11)PROVIDE SPECIFIC WINDOW AND DOOR BUCK
 CONNECTION DETAILS FOR WINDLOAD
 RESISTANCE 1997 SBC 1606
  
 12)PROVIDE DETAILS FOR FRAMING OVER
 WINDOWS ON 2ND FLOOR.
  
 13)BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED,IMPACT FEES MUST BE PAID TO PALM
 BEACH CO., THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-03-09 Cont ID  
Sent By gjoyce Date 2000-03-09 Time 10:52 Rev Time 0.50
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00CARPORT REMOVED FROM PLANS