| Plan Review Stops For Permit 00021287 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-03-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-26 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-26 |
Time |
11:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-09-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-11 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-11 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE THAT NOT ALL OF THE | | | NOTES WERE ADDRESSED FROM THE FIRST | | | REVIEW. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THER ARE ANY QUESTIONS | | | PLEASE CALL!! | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-03-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-03-14 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-03-14 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT ****************** | | | | | | 1)NOTE: PERMIT APPLICATION SHOWS YOU | | | CHANGING THE SERVICE??? NEED TO SEE | | | ELECTRICAL RISER DIAGRAM, SHOWING SIZE | | | OF EQUIPMENT, WIRES, CONDUITS, AND | | | SUBMIT AIC RATING OF EQUIPMENT MAINS. | | | ALL REQ`D BY 215-5/110-9 | | | | | | 2)NOTE: PLEASE NOTE SMOKE DETECTORS REQ` | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS | | | OF YOUR NEW CONSTRUCTION. | | | | | | 3)NOTE; PLEASE SHOW ON PANEL SCHEDULE | | | THE REQ`D CIRCUTS FOR BATH(S)210-11-C-3 | | | | | | 4)NOTE:IF THERE ARE GOOING TO BE MORE | | | THAN ONE CITCUT IN SHED, THEN YOU NEED | | | DISCONNECT AT THAT STRUCTURE. IF ONLY | | | ONE CIRCUT THEN IT MUST BE GFI. PER | | | 225-30-B-2 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW AND APPROVAL. IF THERE ARE ANY | | | QUESTIONS PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2001-03-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-03-30 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-30 00:00:00 | PERMIT VOIDED OWNER INSTALLING WINDOW | | | UNITS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2000-09-14 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-09-14 |
Time |
09:59 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-09-14 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************DENIED****************** | | | NO MECHANICAL INFORMATION PROVIDED FOR | | | REVIEW. PROVIDE PLANS AND INFORMATION |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-03-15 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-03-15 |
Time |
16:09 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-03-15 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | *****************DENIED***************** | | | 1. EXHAUST FAN OR 3'SQ. WINDOW NEEDS TO | | | BE INSTALLED IN BATHROOM SMC 503.3.1 | | | | | | 2. NO A/C PLANS WAS SUBMITTED FOR REVIEW |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-03-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-03-30 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-03-15 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-03-15 |
Time |
06:07 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2000-09-16 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2001-03-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-03-30 |
Time |
12:05 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2000-09-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2000-09-20 |
Time |
07:29 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED | | | | | | 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | | OR SBCCI PRODUCT APPROVALS FOR EACH | | | SPECIFIC TYPE OF EXTRIOR WINDOW OR DOOR | | | TO BE USED. INCLUDING ARCHED WINDOWS | | | SHOWN ON PLANS. | | | | | | 2)PROVIDE EGRESS WINDOW IN BEDROOM. | | | 97 SBC 1005.4 | | | | | | 3)PROVIDE WINDOW SIZES AND TYPES (SINGLE | | | HUNG,AWNING,ETC.)FOR ALL NEW WINDOWS. | | | | | | 4)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | | OR SBCCI PRODUCT APPROVALS, KEY PLAN AND | | | INSTALLATION SCHEDULE FOR STORM PANELS. | | | MISSLE IMPACT PROTECTION IS REQUIRED FOR | | | ALL EXTERIOR GLAZING. CITY OF WPB | | | AMENDMENTS TO 97 SBC. | | | | | | 5)PROVIDE ATTIC ACCESS PER 97 SBC 2309.6 | | | | | | 6)PROVIDE ATTIC VENTIATION.97 SBC 2309.7 | | | | | | 7)PROVIDE WALL SECTION AND CONSTRUCTION | | | DETAILS FOR EXISTING CARPORT THAT IS | | | BEING ENCLOSED. | | | | | | 8)PROVIDE ENERGY CALCULATIONS INCLUDING | | | MANUAL "J" CALCS. PER 79 FL. ENERGY | | | EFFICIENCY CODE. | | | | | | 9)CONNECTOR LSTA 18 SHOWN ON PLANS | | | ATTACHING TRUSSES TO WALL IS AN IMPROPER | | | APPLICATION. USE SIMPSON MTS-12,H6 OR | | | EQUAL. | | | | | | 10)PROVIDE SOIL COMPACTION TEST AT TIME | | | OF FIRST INSPECTION. | | | | | | 11)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY,PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY BLDG. | | | DEPT. BEFORE A PERMIT TO CONSTRUCT WILL | | | BE ISSUED. | | | | | | 12)PROVIDE POSITIVE AND NEGATIVE WIND- | | | LOAD PRESSURES FOR EXTERIOR WINDOW AND | | | DOOR OPENINGS. | | | | | | 13)PROVIDE FRAMING DETAILS FOR ARCHED | | | WINDOWS SHOWN ON PLANS. | | | | | | 14)PLEASE RECHECK DISTANCE BETWEEN SHED | | | AND BED ROOM. FOUNDATION PLAN HAS 4'-0" | | | AND DIMENSION ON SURVEY IS 2.9' | | | (18.9'-16.0'=2.9') |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-03-24 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2000-03-24 |
Time |
11:34 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NEED PRODUCT APPROVALS WINDOWS, DOORS | | | AND ROOF. | | | NEED SEALED ENGINEERED DRAWINGS TRUSSES | | | CURRENT SBCCI CODE IS 1997 PLANS SHOW | | | 1994 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-02-29 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-02-29 |
Time |
10:46 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|