Plan Review Details - Permit 00020799
Plan Review Stops For Permit 00020799
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-03-30 Cont ID  
Sent By bstaples Date 2000-02-18 Time 09:54 Rev Time 0.00
Received By bstaples Date 2000-03-30 Time 08:11 Sent To  
Notes
2001-01-08 00:00:001. OWNER NEEDS TO SIGN FLORIDA ENERGY
 SHEETS, ALL COPIES.OK 3/30/00 WRS
 2. PROVIDE PRODUCT APPROVAL INFORMATION
 ON ALL EXTERIOR WINDOWS AND DOORS. ALL
 GLAZING SHALL BE IMPACT RESISTANT.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2000-09-28 Cont ID  
Sent By dpalmer Date 2000-09-28 Time 20:55 Rev Time 0.00
Received By dpalmer Date 2000-09-28 Time 20:55 Sent To  
Notes
2001-01-08 00:00:00SHEETS E2.01 FOR GFI BRKR CIRCUIT ONLY
 AND SHEET E9.01 FOR PANEL SCHEDULE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-07-26 Cont ID  
Sent By dpalmer Date 2000-07-26 Time 16:35 Rev Time 0.00
Received By dpalmer Date 2000-07-26 Time 16:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-03-29 Cont ID  
Sent By dpalmer Date 2000-03-29 Time 12:59 Rev Time 0.00
Received By dpalmer Date 2000-03-29 Time 12:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-03-08 Cont ID  
Sent By dpalmer Date 2000-03-08 Time 12:30 Rev Time 0.00
Received By dpalmer Date 2000-03-08 Time 12:29 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE:NEED TO LABEL ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED. AS REQ`D BY 210-8-A-6
  
 2)NOTE:PLEASE CORRECT WIRE SIZE GOING TO
 ALL PANELS. YOU SHOW #3 BEING PROTECTED
 BY A 125 AMP BRKR. TABLE 310-16 75C
 COLUMN,,,WIRE IS ONLY RATED FOR 100AMPS.
  
 3)NOTE; YOU ARE SHOWING A/C LOAD AT 100%
 THIS SEEMS TO BE THE DERATED LOAD???
 PLEASE SHOW SIZE OF THE ORIGINAL HEAT
 STRIP.SEE AP-E8.01
  
 4)NOTE: PLEASE SHOW THE LOAD ON "HP"
 AS BEING CONTINUOUS.
  
 PLEASE SUBMIT THE ABOVE INFORAMTION
 FOR REVIEW AND APPROVAL.IF THERE ARE ANY
 QEUSTIONS PLEASE CALL 659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-02-25 Cont ID  
Sent By bstaples Date 2000-02-25 Time 10:47 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00SEE COMMENTS ATTACHED TO PLANS CARSILLO

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2000-07-29 Cont ID  
Sent By cthirben Date 2000-07-29 Time 07:56 Rev Time 1.00
Received By cthirben Date 2000-07-29 Time 07:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-06-24 Cont ID  
Sent By ndenmark Date 2000-06-24 Time 10:37 Rev Time 0.33
Received By ndenmark Date 2000-06-24 Time 10:37 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 1.REVISION DETAIL 2 REFERS TO M307, NOT
 INCLUDED IN THIS REVISION.THIS DETAIL
 DOES NOT SHOW CHASE FOR DUCTS PASSING
 THROUGH SLAB. TO BE PROTECTED PER SKETCH
 ASK-2 FOR APPROVAL

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-06-16 Cont ID  
Sent By cthirben Date 2000-06-16 Time 08:48 Rev Time 1.00
Received By cthirben Date 2000-06-16 Time 08:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-03-08 Cont ID  
Sent By ndenmark Date 2000-03-08 Time 07:46 Rev Time 0.50
Received By ndenmark Date 2000-03-08 Time 07:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2000-08-10 Cont ID  
Sent By tlarge Date 2000-08-10 Time 22:17 Rev Time 0.33
Received By tlarge Date 2000-08-10 Time 21:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-06-26 Cont ID  
Sent By tlarge Date 2000-06-26 Time 15:07 Rev Time 1.00
Received By tlarge Date 2000-06-26 Time 15:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-06-15 Cont ID  
Sent By tlarge Date 2000-06-15 Time 06:23 Rev Time 1.00
Received By tlarge Date 2000-06-15 Time 06:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-03-30 Cont ID  
Sent By tlarge Date 2000-03-30 Time 14:17 Rev Time 1.75
Received By tlarge Date 2000-03-30 Time 14:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-02-26 Cont ID  
Sent By tlarge Date 2000-02-26 Time 14:37 Rev Time 2.75
Received By tlarge Date 2000-02-26 Time 14:37 Sent To  
Notes
2001-01-08 00:00:00 
 ALL BATHROOMS IN THE COVERED DWELLING
 UNIT SHALL COMPLY W/THE PROVISIONS OF
 THE FAIR HOUSING ACT 24 CFR 100.205(C)
 (3)(IV)REQ.#7(2) PARAGRAPH (A) OR (B).
 CLEAR FLOOR SPACE SHALL BE PROVIDED AT
 FIXTURES TO ALLOW A PERSON IN A WHEEL-
 CHAIR OR OTHER MOBILITY AID USE OF THE
 FIXTURES.CLEAR FLOOR SPACE SHALL BE
 SHOWN ON THE PLANS AND DESIGNATE WHICH
 OPTION OF REQUIREMENT #7(A OR B)IS BEING
 USED.
  
 SHT.AP-A7.04-WOOD BACKING FOR GRAB BARS
 ON LONG WALL OF TUB SHALL BE A MAX.OF 6"
 ABOVE TUB.SEE FED.FAIR HOUSING ACT 24
 CFR 100.205.
  
 RELIEF LINES FROM EWH SHALL NOT BE
 TRAPPED PER COUNTYWIDE AMENDMENTS TO SPC
 SEC.507.8.4.
  
 HEATER PANS SHALL COMPLY W/SPC SEC.
 507.8.2.
  
 SUBMIT ENERGY CALCS.AND EF RATING OF EWH
 PER FLA.ENERGY CODE SEC.103.2.
  
 SHOW FIXTURE UNIT LOAD ON SANITARY RISER
 (STACKS AND HORIZONTAL DRAINS.)COMPLY W/
 SPC TABLES 714.1,714.2.
  
 SIZE ALL PORTIONS OF THE DWVSYSTEM.
 (CHECK ALL RISERS-SIZES MISSING FROM
 BUILDING DRAINS,BRANCHES,AND VENTS)
  
 THE CLEAR FLOOR SPACE PROVIDED AT SINKS
 SHALL BE CENTERED ON THE BOWL PER FED.
 FAIR HOUSING ACT 24 CFR 100.205 (C)(3)
 (IV) REQ.#7(1).