Plan Review Details - Permit 00020679
Plan Review Stops For Permit 00020679
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-04-03 Cont ID  
Sent By dpalmer Date 2000-04-03 Time 17:33 Rev Time 0.00
Received By dpalmer Date 2000-04-03 Time 17:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-03-20 Cont ID  
Sent By dpalmer Date 2000-03-20 Time 17:58 Rev Time 0.00
Received By dpalmer Date 2000-03-20 Time 17:58 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLEASE SHOW ALL SMOKE DETECTORS
 REQ`D INSIDE AND OUTSIDE ALL SLEEPING
 ROOMS OF NEW DWELLINGS.THESE ARE REQ`D
 BY 1993/1996 NFPA-72 2-2.1.1.1.
  
 2)NOTE: PLANS SHOW MAIN DISCONNECT?
 RISER DIAGRAM DOES NOT? PLEASE CORRECT
 PLANS.
  
 3)NOTE: 410-8 EVEN FLOURESCENT LIGHTING
 MAY NOT BE ABOVE STORAGE SHELF IN MASTER
 BEDROOM CLOSET.
  
 4)NOTE: PLEASE NOTE THE MISSING OUTLETS
 REQ`D BY 210-52 IN TWO BEDROOMS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW AND APPROVAL. IF THERE ARE ANY
 QUESTIONS PLEASE CALL 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-01-19 Cont ID  
Sent By jleech Date 2001-01-19 Time 07:12 Rev Time 0.33
Received By jleech Date 2001-01-19 Time 07:12 Sent To  
Notes
2001-01-19 00:00:00REVISED PLAN. REVERSE OF FLOOR LAYOUT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-02-26 Cont ID  
Sent By jleech Date 2000-02-26 Time 12:36 Rev Time 0.25
Received By jleech Date 2000-02-26 Time 12:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2000-09-02 Cont ID  
Sent By tlarge Date 2000-09-02 Time 05:57 Rev Time 0.33
Received By tlarge Date 2000-09-02 Time 05:57 Sent To  
Notes
2001-01-08 00:00:00SEE ATTACHED FOR GAS REQS.
  
 SHOW SIZE OF MAIN SUPPLY FROM METER.
 SGC SEC.301,305.4(A).

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-09-01 Cont ID  
Sent By tlarge Date 2000-09-01 Time 18:24 Rev Time 0.20
Received By tlarge Date 2000-09-01 Time 18:24 Sent To  
Notes
2001-01-08 00:00:00REVISED SANITARY RISER.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-02-19 Cont ID  
Sent By tlarge Date 2000-02-19 Time 06:05 Rev Time 0.33
Received By tlarge Date 2000-02-19 Time 06:01 Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
 FIXTURES DOWNSTREAM OF WATER CLOSETS
 SHALL BE INDIVIDUALLY VENTED PER SPC SEC
 913.2.
  
 LOCATION OF PLUMBING FIXTURES ON
 SANITARY RISER SHALL CORRELATE W/FLOOR
 PLAN.COUNTYWIDE AMENDMENTS TO SPC SEC.
 104.2.1.SUBMIT REVISED SIGNED AND SEALED
 RISER DIAGRAM.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-04-07 Cont ID  
Sent By lmartine Date 2000-04-07 Time 12:50 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00*************PROVISO********************
  
 1]BROWARD COUNTY REPORT FOR EXT. DOOR
 MUST BE SIGNED AND SEALED BY ARCH. OF
 RECORD TO BE EXCEPTABLE.
 2]GLASS BLOCK MUST BE 1HR CONSTRUCTION,
 SUBMIT SPECIFICATIONS.
 3]SECTION 1804.1.3,1997 SBC REQUIRES THE
 BOTTOM OF THE FOOTERS TO BE 12" BELOW
 FINISH GRADE,ALSO SEE 1804.6.1.3.
 4]SECTION 2306.1 REQUIRES 4"SPACING IN
 ZONE 3 ON PAGE A-6 [FOR THE ROOF
 SHEATHING].
 5]FIXED WINDOWS AT REAR ELEVATION ARE
 NOT IN COMPLIANCE WITH ELEVEN FOOT
 SPAN.SUBMIT NEW PRODUCT REPORT OR
 REVISE OPENINGS TO COMPLY.
 6]SUBMIT INSTALLATION SCHEDULE AND SPEC.
 OUT ANCHORS TO BE USED FOR STORM
 PANELS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-02-16 Cont ID  
Sent By gjoyce Date 2000-02-16 Time 11:04 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***