Plan Review Details - Permit 00020599
| Plan Review Stops For Permit 00020599 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-03-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-03-20 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-03-20 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE: NEED TO SHOW A/C EQUIPMENT AND | | | DISCONNECT REQ`D BY 440-11 AND 215-5 | | | ALSO RECEPT. PER MECH CODE. | | | | | | 2)NOTE: PLEASE LIST THE REQ`D DEDICATED | | | BATH(S) CIRCUT PER 210-11-C-3.MUST BE | | | 20AMP AND #12 AWG. | | | | | | 3)NOTE: PLEASE SHOW THE EQUIPMENT GROUND | | | -ING CONDUCTOR REQ`D AND SIZE PER NEC | | | 250-122 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW AND APPROVAL. IF THERE ARE ANY | | | QUESTIONS PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-02-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-02-26 |
Time |
12:44 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-02-26 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-02-19 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-02-19 |
Time |
06:42 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-02-19 |
Time |
06:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | LOCATION OF PLUMBING FIXTURES ON | | | SANITARY RISER DOESN'T CORRELATE W/FLOOR | | | PLAN.COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 104.2.1. | | | | | | WATER CLOSET IN 2ND.FLOOR MASTER BATH | | | NOT VENTED.SPC SEC.901.2. | | | | | | MAX.OF 4 FIXTURE UNITS PERMITTED ON 2" | | | WET VENT PER SPC.SEC.911.1.(1).(SEE 1ST. | | | FLR.M.B.) | | | | | | ONLY FIXTURE DRAINS PERMITTED ON WET | | | VENTS PER COUNTYWIDE AMENDMENTS TO SPC | | | SEC.911.1.1.(SEE 1ST.FLR.M.B.) |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2000-04-04 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-04-04 |
Time |
14:08 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-04-04 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | ****************PROVISO***************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COPIES OF SBCCI OR | | | METRO DADE PRODUCT APPROVALS FOR: | | | OUTSWING DOOR WITH SIDELITE | | | ARCH TRANSOMS | | | CIRCLE WINDOW | | | 12'FIX WINDOW | | | 12'SLIDING GLASS DOOR | | | | | | 2)PROVIDE STORM PANEL DRAWINGS THAT ARE | | | SIGN, DATED AND HAVE RAISED SEAL AND | | | IDENTIFY MOUNTING AND ANCHORS TO BE USED | | | | | | 3)PROVIDE SPECIFICATIONS FOR 1 HR GLASS | | | BLOCK. | | | | | | 4)PROVIDE PRODUCT APPROVAL FOR ROOF | | | COVERING UNDER SEPERATE PERMIT. | | | | | | 5)BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO., THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-02-14 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-02-14 |
Time |
11:43 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|