Plan Review Details - Permit 00020553
| Plan Review Stops For Permit 00020553 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-05-05 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-05-05 |
Time |
11:03 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2000-05-05 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | *****************PROVISO**************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COPIES OF SBCCI OR | | | METRO DADE PRODUCT APPROVALS FOR | | | WINDOWS BEING USED. | | | | | | 2)PROVIDE MISSILE IMPACT RESISTANCE | | | INFORMATION UNDER SEPERATE PERMIT. | | | | | | 3)PROVIDE MECHANICAL DRAWINGS WITH | | | MECHANICAL PERMIT. | | | | | | 4)BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO.,THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-05-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-01 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-01 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-02-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-02-21 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-21 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: NEED TO SHOW SERVICE FOR DETACH- | | | -ED BLDG. SHOE WHERE THE SERVICE IS | | | COIMING FROM. | | | | | | 2)NOTE: YOU SHOW A 220V OUTLET?? WHAT IS | | | THIS FOR ?? NEEDS TO BE LABELED ON PLANS | | | FOR THE PURPOSE OF THIS OUTLET.215-5 | | | NOTE:IF THE OUTLET IS FOR RANGE? THEN | | | SEPARATE ZONING APPROVAL IS NEEDED FOR | | | THE SECOND MEANS OF COOKING. | | | | | | 3)NOTE:LIST ALL CIRCUTS ON PAMEL SCHED. | | | TO INCLUDE THE DEDICATED BATH(S) CIRCUT | | | REQ`D BY 210-52D. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW AND APPROVAL. IF THERE ARE ANY | | | QUESTIONS PLEASE CALL. 659-8096 EXT8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-02-23 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-02-23 |
Time |
12:23 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-02-23 |
Time |
12:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-05-01 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-05-01 |
Time |
14:16 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-05-01 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-02-22 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-02-22 |
Time |
06:14 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-02-22 |
Time |
06:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SHOW LXW OF SHOWER.SHOWER SHALL BE A MIN | | | OF 30" WIDE AND MIN.FLOOR AREA OF 1024 | | | SQ.IN.PER COUNTYWIDE AMENDMENTS TO SPC | | | SEC.409.8.2.1. | | | | | | SUBMIT SANITARY AND WATER RISER FOR | | | REVIEW PER COUNTYWIDE AMENDMENTS TO SPC | | | SEC.104.2.1. | | | | | | SHOW FIXTURE CLEARANCE OF WATER CLOSET | | | PER SPC SEC.403.4. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-02-14 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-02-14 |
Time |
11:20 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|