Plan Review Details - Permit 00020469
| Plan Review Stops For Permit 00020469 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-03-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-03-14 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-03-14 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-02-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-02-21 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-21 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************ UNSAT ******************** | | | | | | 1)NOTE: NEED TO SHOW GROUNDING ELECTRODE | | | SYSTEM. TO BLDG.STEEL OF NEW ADDITION. | | | NEEDS TO GO TO COLD WATER PIPE AND | | | GROUND ROD. PER 250-81 | | | | | | 2)NOTE: 1 3/4 CONDUIT IS NOT A STANDARD | | | SIZE. PLEASE CORRECT. | | | | | | 3)NOTE:NEED TO SUBMIT THE AIC RATING OF | | | EQUIPMENT MAINS. MAIN MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT. AS REQ`D BY | | | ART:110-9/110-10. 215-5 | | | | | | 4)NOTE: PLEASE CHECK LOAD CALCULATIONS,, | | | YOU SHOW ONLY ONE SMALL APPLIANCE CIRCUT | | | ???? TWO REQ`D BY CODE. | | | WHAT IS BEING USED FOR A/C, HEAT??? | | | IF THERE IS CENTRAL AIR THEN IT IS TO BE | | | CALCUALTED. | | | ALSO 40% OF 6553 IS NOT 262. PLEASE | | | CORRECT THIS FIGURE FOR LOAD. | | | IF THERE ARE INDIVIDUAL WALL A/C UNITS, | | | THEN FIGURE NAMEPLATE RATINGS. | | | | | | NEED TO HAVE ALL THE ABOVE INFORMATION | | | SUBMITTED FOR REVIEW AND APPROVAL. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-02-23 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-02-23 |
Time |
12:26 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-02-23 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO MECH INCLUDED FOR REVIEW SUBMIT INFO | | | WITH MECH PERMIT APPLICATION PRIOR TO | | | ANY WORK BEING DONE |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-02-22 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-02-22 |
Time |
06:44 |
Rev Time |
0.50 |
| Received By |
pschmitz |
Date |
2000-02-22 |
Time |
06:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2000-03-14 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2000-03-14 |
Time |
16:44 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-02-14 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-02-14 |
Time |
11:25 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|