Plan Review Details - Permit 00020363
| Plan Review Stops For Permit 00020363 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-03-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-03-15 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-03-15 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-03-08 |
Time |
20:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-03-08 |
Time |
20:28 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | | | NOTES ON PLANS | | | PLEASE CORRECT ENTIRE PANEL SCHEDULE. | | | CORRECT WIRE SIZES, BRKRS, AND LOADS. | | | MISSING OUTLET | | | MISSING SMOKE DETECTOR |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-08-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-08-30 |
Time |
18:02 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-08-30 |
Time |
18:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-03-16 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-03-16 |
Time |
14:42 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-03-16 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-02-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-02-26 |
Time |
11:46 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2000-02-26 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED; | | | ALL PROBLEMS IN QUEST QUARTERS; | | | 1.FIRST FLOOR CFM'S REQUIRED FOR ALL | | | DROPS. | | | 2.SECOND FLOOR, RETURN AIR NOT PERMITED | | | IN BATHROOM. | | | 3.A/C UNIT TO SMALL FOR CFM'S SHOWN. | | | 790 CFM WITH ONE DROP MISSING | | | CALCULATIONS. 1 1/2 TON A/H WILL | | | PROVIDE ONLY 600 CFM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-11-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-20 |
Time |
16:59 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2000-11-20 |
Time |
16:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-02-11 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-02-11 |
Time |
07:16 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-02-11 |
Time |
07:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-05-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2000-05-09 |
Time |
09:47 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2000-04-24 |
Time |
08:04 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED | | | | | | 1)DESIGN COMPLIANCE FORM SPECIFIES A | | | MEAN ROOF HEIGHT TO BE 15',I CALCULATE | | | IT TO BE 24'10" CLARIFY & RECALCULATE | | | ALL UPLIFTS,PROVIDE CORRECTED FORM. | | | 2)EXTERIOR DOOR AT GUEST SUITE DOES NOT | | | COMPLY WITH EGRESS REQUIREMENTS.EGRESS | | | DOORS SHALL BE OF THE SIDE SWINGING | | | TYPE AND SHALL PROVIDE A CLEAR OPENING | | | OF NOT LESS THAN 32". 97SBC-1012.1 | | | 3)PROVIDE ENERGY CALCS.AND MANUAL J FOR | | | MAIN HOUSE | | | 4)PLANS INDICATE 50GAL WATER HEATER FORM | | | 600A-97 & EPL DISPLAY CARD INDICATE | | | 30 GAL. WATER HEATER,CLARIFY | | | 5)PROVIDE PRODUCT APPROVALS FOR INSWING | | | EXTERIOR DOOR AT GUEST SUITE | | | 6)PROVIDE PRODUCT APPROVALS FOR STORM | | | PANELS | | | 7)PROVIDE SOIL BEARING TEST REPORT PRIOR | | | TO FIRST INSPECTION |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-02-09 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-02-09 |
Time |
12:00 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|