Plan Review Details - Permit 00020337
Plan Review Stops For Permit 00020337
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2000-12-04 Cont ID  
Sent By drunnels Date 2000-12-04 Time 12:27 Rev Time 1.00
Received By drunnels Date 2000-12-04 Time 12:27 Sent To  
Notes
2001-01-08 00:00:00STOREFRONT SHOP DRAWINGS AND PRODUCT
 APPROVALS

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2000-12-04 Cont ID  
Sent By drunnels Date 2000-12-04 Time 11:35 Rev Time 3.00
Received By drunnels Date 2000-12-04 Time 11:35 Sent To  
Notes
2001-01-08 00:00:00REVISION #15 OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2000-10-31 Cont ID  
Sent By drunnels Date 2000-10-31 Time 08:39 Rev Time 8.00
Received By drunnels Date 2000-10-31 Time 08:38 Sent To  
Notes
2001-01-08 00:00:001. SUBMIT DETAIL FOR WALL BETWEEN
 CORRIDORS 322 & 322B

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2000-08-30 Cont ID  
Sent By drunnels Date 2000-08-30 Time 12:09 Rev Time 1.00
Received By drunnels Date 2000-08-30 Time 12:08 Sent To  
Notes
2001-01-08 00:00:001.SHEET A1.3 INDICATES TWO(2) AUDITORUIM
 18
 2.REVISE "EGRESS LOAD-LEVEL 3" TABLE TO
 REFLECT OCCUPANT CHANGES TO AUDITORUIM
 15 TO 18

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-04-07 Cont ID  
Sent By bstaples Date 2000-04-07 Time 08:50 Rev Time 20.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:001. NO MECHANICIAL PERMITS OR WORK IS
 COVERED BY THIS PERMIT.
 2. SMOKE DETECTORS SHALL BE INSTALLED IN
 ATRUM AS PER 1997 SBC, SECTION 414.6.1&2
 3. INCREASE THE FIRE RATING FROM ROOM
 120 TO EXIT 113B FROM ONE TO TWO HOURS.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2000-12-14 Cont ID  
Sent By jleahy Date 2000-12-14 Time 07:55 Rev Time 0.00
Received By jleahy Date 2000-12-14 Time 07:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2000-09-27 Cont ID  
Sent By jleahy Date 2000-09-27 Time 08:50 Rev Time 0.00
Received By jleahy Date 2000-09-27 Time 09:24 Sent To  
Notes
2001-01-08 00:00:00RISER DIAGRAM NOTES ON PAGE E-14 SHOW 7
 SETS OF 500 KCMIL WIRE FEEDING MSB AT 75
 DEGREES "C" WIRE DOES NOT MEET CODE, IF
 YOU ARE USING THE 90 DEGREE COLUMN THEN
 SHOW LISTING FOR 90 DEGREE "C" ON THE
 TERMINATIONS PER 110-14C2
  
 LOAD CALCULATION FOR MSB STILL SHOWS NO
 LOAD FOR FIRE PUMP IT MAY NOT BE FED BY
 MAB BUT THE CONDUCTORS THAT FEED MSB
 ALSO FEED THE FIREPUMP!!!!!!!!!!!!!!!!

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2000-08-29 Cont ID  
Sent By jleahy Date 2000-08-29 Time 13:27 Rev Time 1.30
Received By jleahy Date 2000-08-29 Time 14:07 Sent To  
Notes
2001-01-08 00:00:00REVISION #14 ONLY A DISC. TO TRANSF,
 SEE REVSION 6/1/2000 FOR REMAINING
 COMMENTS.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2000-06-01 Cont ID  
Sent By jleahy Date 2000-06-01 Time 11:31 Rev Time 0.00
Received By jleahy Date 0200-06-01 Time 14:09 Sent To  
Notes
2001-01-08 00:00:001-MSB CALC DOES NOT SHOW ANY LOAD FOR TH
 FIRE PUMP!
 2-MSB LOAD CALC SHOWS LOADS FOR THE
 INDIVIDUAL PANEL, BUT THE LOAD ON THE
 PANELS DOES NOT MATCH WHAT IS SHOWN ON
 MSB CALC.215-5
 3-PLAN CALLS FOR 9 4"PIPES FOR THE SERVI
 BUT RISER SCHEDULE SHOWS 6 PLEASE FIX!
 4-RISER DIAGRAM STILL SHOWS NO DISCONNEC
 AT THE TRANSFER SWITCH FOR THE EMERG.
 FEED FROM THE GENERATOR, MAIN AT GEN.
 TO REMOTE FROM THE OTHER MAINS IN THE
 GEAR ROOM.
 5-NO PANEL SCHEDULES SHOWN FOR CCA1 THRU
 CCA4 PANELS AND ALSO CG PANEL.THERE
 ARE NO LOADS SHOWN ON THE DRAWINGS FOR
 PANEL CG?
 6-FROM DP1 AND DP2 THE PLAN SHOWS EACH
 FEEDING A SET OF PANEL THAT ARE LISTED
 AS CCA1 THRU CCA4 PLEASE CHANGE ON SET
 SO NOT CONFUSE THE INSTALLER OR INSP.
 7-ML"X" PANELS IN EACH SPACE SHOWS A #12
 WIRE ON A 60A BREAKER?ALSO SHOWS 3
 #6'S FEEDING A WIRE WAY, WHAT KIND OF
 LOAD IS THIS?
 8-THE 300KVA TRANSF. SHALL COMPLY WITH
 450-21B EXP.1&2!
 9-PAGE E1 SHOWS THE FIRE PUMP TO BE 25HP
 RISER SHOWS 100HP!GENERATOR AT 150KW
 AND RISER SHOWS 230KW?
 10-EDP LOAD CENTER SHOWS LOADS FOR THE
 INDIVIDUAL PANELS DIFFERENT THAN WHAT
 IS SHOWN AT THE PANEL CALCS. SHOW HOW
 THIS WAS DONE.SEE 215-5 FOR WHAT IS
 NEEDED!!!!!!!!
 11-EMS SYSTEM ISTHIS BEEN DELETED NEW PG
 13 SHOWS NO LOADS!!!!!!!!!!!!
 12-800AMP MAIN FOR FIRE PUMP CAN NOT BE
 MOUNTED ON THE MAIN SWITCH GEAR, IT HA
 TO BE REMOTE!!!!!!!!!!!!!!!!!!!!!!

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-08-29 Cont ID  
Sent By dpalmer Date 2000-06-01 Time 18:42 Rev Time 0.00
Received By jleahy Date 2000-08-14 Time 09:30 Sent To  
Notes
2001-01-08 00:00:00**************** PROVISO ***************
  
 1)NOTE: PLEASE SEE ORIGINAL NOTES ATTACH
 -ED. NOTE THAT A DISCONNECT IS REQ`D
 INLINE FROM GENERATOR TO TRANSFER SWITCH
 AS PER 230-70-A AND MUST BE GROUPED,230-
 72. PLEASE REVISE AND SUBMIT FOR REVIEW
 BEFORE ROUGH ELECTRICAL INSPECTION.
 NOTE THE REQ`MENTS OF 230-70-B
  
 2)NOTE; ALSO PLEASE INDICATE ALL THE
 RATINGS OF TRANSFORMERS OVER 112 1/2 KVA
 SEE 450-21-B FOR INSTALLATION REQ`MENTS.
 INDICATE THIS ON PLANS 215-5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW BEFORE ROUGH ELECTRICAL INSPEC-
 -TION. IF THERE ARE ANY QUESTIONS PLEASE
 CALL (561) 659-8096 EXT 8372/8451

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-02-23 Cont ID  
Sent By jleahy Date 2000-02-23 Time 12:33 Rev Time 0.00
Received By jleahy Date 2000-02-23 Time 12:57 Sent To  
Notes
2001-01-08 00:00:001- MAIN SWITCH GEAR ROOM NEEDS TO COMPLY
 WITH 110-16 FOR WORKING CLEARANCES,
  
 2- ROOM MEETS CODE BUT IF SOMETHING IS
 ADDED OR MOVED IT COULD BECOME A
 PROBLEM.
  
 3- PAGE E-14 TRANSFER SWITCH HAS NO DISC
 ON THE LINE SIDE IN THE GEAR ROOM.
 MAINS ARE TO BE GROUPED ONE ON THE
 1ST AND THE REST ON THE SECOND IS TO
 REMOTE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2000-11-29 Cont ID  
Sent By mcarsill Date 2000-11-29 Time 08:44 Rev Time 0.00
Received By mcarsill Date 2000-11-29 Time 08:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2000-09-27 Cont ID  
Sent By mcarsill Date 2000-09-27 Time 10:49 Rev Time 0.00
Received By mcarsill Date 2000-09-27 Time 10:49 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-08-29 Cont ID  
Sent By mcarsill Date 2000-08-29 Time 10:40 Rev Time 0.00
Received By mcarsill Date 2000-08-29 Time 10:40 Sent To  
Notes
2001-01-08 00:00:001) CORRIDOR 301C TO BE FIRE RATED FOR
 AT LEAST ONE HOUR FROM STORAGE ROOM 301A
 2) PROVISIONS ARE TO BE MADE FOR AT
 LEAST TWO HANDICAPPED PERSONS IN THE
 PREMIER BAR.
 3) ENSURE THAT EMERGENCY LIGHTING IS
 PROVIDED IN THE BAR AREA.
 4) NO COOKING THAT PRODUCES SMOKE OR
 GREASE LADEN VAPORS WILL BE ALLOWED IN
 PREMIER BAR WITHOUT THE PRESENCE OF
 A HOOD, DUCT AND EXTINGUISHING SYSTEM.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-04-19 Cont ID  
Sent By bstaples Date 2000-02-24 Time 10:10 Rev Time 5.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED MIKE CARSILLO 2/22/00 SEE NOTES
 ON PLANS.
 RELEASED WITH CONDITIONS SEE LETTER M.
 CARSILLO ATTACHED TO PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 10 Status P Date 2000-12-07 Cont ID  
Sent By ndenmark Date 2000-12-07 Time 09:44 Rev Time 3.00
Received By ndenmark Date 2000-12-07 Time 09:44 Sent To  
Notes
2001-01-08 00:00:00REVISION 15 AND 16 SHEETS M-1,2,4 AND 5
 AS STAMPED AND DATED 12-7-00

Review Stop M MECHANICAL (A/C)
Rev No 9 Status F Date 2000-10-28 Cont ID  
Sent By ndenmark Date 2000-10-28 Time 12:39 Rev Time 1.00
Received By ndenmark Date 2000-10-28 Time 12:39 Sent To  
Notes
2001-01-08 00:00:00REVISION (15) DATED 9/20/00 DENIED
  
 1. 1997 SMC 501.3 THE AIR DISCHARGED BY
 EVERY MECHANICAL EXHAUST SYSTEM SHALL BE
 DISCHARGED OUTDOORS. EXHAUSTING AIR INTO
 AN ATTIC OR CRAWL SPACE SHALL BE PROHIB-
 ITTED.

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2000-08-28 Cont ID  
Sent By ndenmark Date 2000-08-28 Time 15:12 Rev Time 1.00
Received By ndenmark Date 2000-08-28 Time 15:12 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 LIFESAFETY AND FLOOR PLAN A 1.3 DATED
 8/18/00 SHOW RATED WALL ADDITION TO
 PREMIER ROOM. NEED MECHANICAL PLANS
 SHOWING LOCATION AND SPEC OF FIRE DAMPER
 REQ'D TO PROTECT OPENINGS FOR DUCTS THRU
 WALL.
 SUBMIT PRIOR TO INSPECTION OF THIS
 SYSTEM

Review Stop M MECHANICAL (A/C)
Rev No 7 Status F Date 2000-07-31 Cont ID  
Sent By ndenmark Date 2000-07-31 Time 13:58 Rev Time 1.00
Received By ndenmark Date 2000-07-31 Time 13:58 Sent To  
Notes
2001-01-08 00:00:00DENIED FOR MECHANICAL RESPECTIVE OF THE
 PLAN TO START UP BY STAGES OF THE AIR
 CONDITIONING AND PERMANENT POWER FOR
 MUVICO
  
 AFTER REVIEWING THE COMMENTS BY THE FIRE
 PLAN REVIEW AND ELECTRICAL PLAN REVIEW
 THE MECHANICAL ASPECTS OF THIS PROPOSED
 STARTUP ARE DENIED.
 THE PERMANENT POWER AND AIR CONDITIONING
 SHOULD NOT BE ALLOWED UNTIL FIRE ALARM
 AND FIRE SPRINKLER SYSTEMS ARE IN PLACE
 ANDFUNCTIONAL. THIS WAS ADDRESSED AT
 TIME OF THE ORIGINAL MEETING DISCUSSING
 THIS DEPARTMENTS REQUIREMENTS PRIOR TO
 PERMANENT POWER BEING RELEASED
 GENERALLY THERE IS NO PROBLEM WITH THE
 PROPOSED PHASING OF MECHANICAL SYSTEMS
 ONCE THE ISSUES FROM FIRE AND ELECTRICAL
 ARE ADDRESSED

Review Stop M MECHANICAL (A/C)
Rev No 6 Status F Date 2000-07-12 Cont ID  
Sent By ndenmark Date 2000-07-12 Time 08:19 Rev Time 1.00
Received By ndenmark Date 2000-07-12 Time 08:19 Sent To  
Notes
2001-01-08 00:00:00********DENIED*************************
  
 1) REVISION 8 INDICATES UTILIZING GYP.
 BD. ENCLOSURE AS AIR PLENUM ELIMINATING
 DUCT AND SMOKE FIRE DAMPERS AS INDICATED
 ON MECH REVISION 6.
 2)1997 SBC 705.2.2 REQUIRES SHAFT ENCLOS
 URES AT ALL PENETRATIONS OF FLOOR OPEN-
 INGS. PROVIDE SHAFT DETAIL INCLUDING
 RATING FOR ABOVE ENCLOSURES
 3) BLDG REVISION 8 SAYS SEE MECH DRAWING
 NO MECHANICAL DRAWINGS INCLUDED WITH
 THIS REVISION. MECHANICAL REVISION REQ'D
 TO PROVIDE COMPLETE REVIEW OF THIS
 CHANGE

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2000-06-05 Cont ID  
Sent By ndenmark Date 2000-06-05 Time 14:41 Rev Time 1.00
Received By ndenmark Date 2000-06-05 Time 14:41 Sent To  
Notes
2001-01-08 00:00:00FAILED
  
 1) SLOPE FOR GREASE DUCT MIN. 1" PER 12"
 PER 1997 SMC 505.4
 2) PROVIDE SPECIFIC DETAIL FOR KITCHEN
 DUCT AND HOODS AT TIME OF PERMIT APPLICA
 TION FOR HOOD INSTALLATION PRIOR TO ANY
 WORK ON HOOD OR DUCT SYSTEM
 3) EXHAUST DUCT TO BE RUN IN ENCLOSURE
 DEDICATED TO SINGLE EXHAUST DUCT AND FOR
 NO OTHER PURPOSE
 4) MIN CLEARANCE FROM DUCT TO INSIDE OF
 ENCLOSURE IS 6"

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2000-05-12 Cont ID  
Sent By ndenmark Date 2000-05-12 Time 15:02 Rev Time 1.00
Received By ndenmark Date 2000-05-12 Time 15:02 Sent To  
Notes
2001-01-08 00:00:00FIRE REVIEW COMMENTS TO BE ADDRESSED

Review Stop M MECHANICAL (A/C)
Rev No 3 Status A Date 2000-05-12 Cont ID  
Sent By ndenmark Date 2000-05-01 Time 14:29 Rev Time 1.00
Received By ndenmark Date 2000-05-01 Time 14:28 Sent To  
Notes
2001-01-08 00:00:00PREVIOUS COMMENTS ABOUT SHAFT DETAIL NOT
 ADDRESSED
 NEED SHAFT DETAILS SHOWN
 ACCEPTED BY REVISION

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2000-04-07 Cont ID  
Sent By ndenmark Date 2000-04-04 Time 07:31 Rev Time 2.00
Received By ndenmark Date 2000-04-04 Time 07:31 Sent To  
Notes
2001-01-08 00:00:00MECHANICAL REMOVED FROM THIS PLAN REVIE
 DENIED:
 1) STILL NEED SHAFT DETAIL FOR BATHROOM
 EXHAUST AND AIR CONDITIONING DUCT SYSTEM
 2) SHAFT DETAIL FOR PROJECTORS DOES NOT
 SHOW PROTECTION OF SHAFT AT BOTTOM OF
 SHAFT AT LEVEL 3 FLOOR, PROVIDE DETAIL
 OF SHAFT PROTECTION AT BOTTOM OF SHAFT
 PER 1997 SMC 601.1.2.2 AND 610.4
 3) PLEASE SPECIFY DUCT MATERIAL FOR
 PROJECTION EXHAUST DUCT
 4) SUPPY AIR DUCT FOR ATRIUM EXHAUST
 SYSTEM HAS FIRE DAMPERS. PROVIDE INFOR-
 MATION ON FIRE DAMPERS,I.E CAN THESE BE
 REMOTELY OPERATED TO OVERIDE POSITION?
 IF THESE DAMPERS SHUT THE REQUIRED
 AMOUT OF MAKE UP AIR WILL NOT BE PROVIDE
 CREATING A NEGATIVE PRESSURE ON THE
 ATRIUM. THIS ISSUE NEEDS TO BE ADDRESSED
 AND RESOLVED AS PART OF THE ATRIUM
 EXHAUST SEQUENCE OF OPERATION

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-04-07 Cont ID  
Sent By ndenmark Date 2000-02-17 Time 11:18 Rev Time 16.00
Received By ndenmark Date 2000-02-17 Time 11:18 Sent To  
Notes
2001-01-08 00:00:00MECH REMOVED FROM PRIMEDENIED*******
 1) PROVIDE SHAFT DETAIL FOR PROJECTOR
 EXHAUST SYSTEMS
 2) PROVIDE INFORMATION ON CODE REQUIRED
 BACKDRAFT DAMPERS FOR EXHAUST FANS
 3) PROJECTOR EXHAUST DUCT DETAIL SHOWS
 FLEXABLE METAL DUCT. 1997 SBC 403.3.8.1
 DOES NOT ALLOW FLEX DUCT EXCEPT AT CONN-
 ECTION TO PROJECTOR
 4) VARIABLE OCCUPANCY NOT ALLOWED FOR
 THE THEATERS. 50% REDUCTION IS NOT A
 REALISTIC EXPECTATION FOR OCCUPANCY FOR
 THIS PROJECT
 5) LOCAL CODE REQUIRES 18" MIN. CLEARANC
 BETWEEN ROOF SURFACE AND BOTTOM OF SUPP-
 ORT STRUCTURE FOR CONDENSING UNITS
 6) PROVIDE DETAIL FOR SHAFT ENCLOSURES
 TO SHOW COMPLIANCE WITH 1997 SMC AND
 NFPA 96
 7) PROVIDE SEQUENCE OF OPERATION FOR
 ATRIUM EXHAUST SYSTEM
 8) PROVIDE LOCATION AND ACCESS TO DUCT
 SMOKE DETECTORS TO SHOW COMPLIANCE WITH
 1997 SMC AND NFPA 90A
 9) PROVIDE AIR BALANCE SCHEDULE FOR
 BUILDING TO SHOW COMPLIANCE WITH 1997
 SMC 501.2
 ABOVE INFORMATION REQUIRED TO PROVIDE
 REVIEW OF THIS PROJECT. INSUFFICIENT
 INFORMATION INCLUDED FOR REVIEW

Review Stop P PLUMBING
Rev No 10 Status P Date 2000-12-11 Cont ID  
Sent By pschmitz Date 2000-12-11 Time 17:25 Rev Time 2.00
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 9 Status F Date 2000-09-25 Cont ID  
Sent By tlarge Date 2000-09-25 Time 16:16 Rev Time 2.75
Received By pschmitz Date 2000-09-25 Time 13:38 Sent To  
Notes
2001-01-08 00:00:001)REVISIONS THAT INCLUDE THE BAR AREA
 CANNOT BE REVIEWED UNTIL 2 SETS OF PLANS
 FOR THE ENTIRE BAR AREA ARE ROUTED TO
 THE DEPT.OF BUSINESS REGULATION.COUNTY-
 WIDE AMENDMENTS TO SPC SEC.101.4.7.
  
 2)THE WATER RISER DIAGRAM IS LACKING
 PIPE SIZES IN AREAS.PLEASE REVIEW THE
 RISER DIAGRAM AND MAKE ALL NECESSARY
 ADJUSTMENTS.COUNTYWIDE AMENDMENTS TO SPC
 104.2.1.
  
 3)SHUT-OFF VALVES ARE REQD.ON THE WATER
 DISTRIBUTION BRANCH MAINS PER SPC SEC.
 610.4.2.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 8 Status F Date 2000-08-30 Cont ID  
Sent By tlarge Date 2000-08-30 Time 16:51 Rev Time 1.25
Received By tlarge Date 2000-08-29 Time 19:37 Sent To  
Notes
2001-01-08 00:00:001)PLANS SHALL BE REVIEWED AND APPROVED
 BY THE DEPT.OF BUSINESS REGULATION
 PER COUNTYWIDE AMENDMENTS TO SPC SEC.
 101.4.7.
  
 2)SHT.P7.1-PREMIER BAR AREA-PLAN VIEW
 SHOWS A FLOOR SINK AND THE SANITARY
 RISER SHOWS A HAND SINK.CLARIFY.
  
 3)SHT.P8-SEE REVISION DELTA 14-SHOW
 LOCATION OF THIS PIPING ON THE PLAN
 VIEW.COUNTYWIDE AMENDMENTS TO SPC SEC.
 104.2.1.
  
 4)SHT.P8-PREMIER BAR AREA-SIZE ALL
 SECTIONS OF THE DWV SYSTEM.COUNTYWIDE
 AMENDMENTS TO SPC SEC.104.2.1.
  
 5)CONTACT R.COMPO W/CITY OF WPB
 UTILITIES FOR APPROVAL OF WASTE FROM
 ELEVATORS TO SANITARY SYSTEM.CALL
 561-835-7423.
  
 6)SHT.P8-SHOW LOCATION OF TERMINATION
 POINT OF 3"DRAIN FROM OIL INTERCEPTOR.
  
 7)TWO WAY CLEANOUTS ARE REQD.ENTERING
 AND LEAVING INTERCEPTORS.SPC SEC.710.4.
  
 8)WATER HEATERS SHALL BE READILY
 ACCESSIBLE.SPC 507.1.
  
 9)SHT.P9.1-WATER SUPPLY CONTROL SHALL
 COMPLY W/SPC SEC.610.4.2.(VALVES ARE
 REQD.ON THE BRANCH LINES.)
  
 10)CLEARLY SHOW THE LOCATIONS OF THE
 INTERCEPTORS ON THE PLANS.SPC 104.2.1.
  
 11)CLEARLY LABEL RISERS,STACKS ,ETC.FOR
 IDENTIFICATION AND LOCATION.COUNTYWIDE
 AMENDMENTS TO SPC SEC.104.2.1.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 7 Status F Date 2000-06-28 Cont ID  
Sent By tlarge Date 2000-06-28 Time 16:25 Rev Time 2.00
Received By tlarge Date 2000-06-28 Time 16:25 Sent To  
Notes
2001-01-08 00:00:00SUBMIT MANUF.SHEETS/DETAIL OF OIL
 INTERCEPTOR.SPC SEC.1004.2.
  
 CLEARLY IDENTIFY SPACE/LOCATION OF OIL
 INTERCEPTOR.INTERCEPTOR SHALL BE
 ACCESSIBLE.SPC SEC.1004.8.
  
 SUBMIT SANITARY AND WATER ISOMETRICS FOR
 THE CHANGES TO THE SYSTEMS.COUNTYWIDE
 AMENDMENTS TO SPC SEC.104.2.1.
  
 SHT.P-7-INDICATE THE FLOOR LEVEL OF
 THE STRUCTURE FOR THESE CHANGES.SPC SEC.
 104.2.1.
  
 WATER HEATER SHALL BE READILY ACCESSIBLE
 PER SPC SEC.501.7.PROVIDE FIXED LADDER
 OR RELOCATE WATER HEATER TO FLOOR.

Review Stop P PLUMBING
Rev No 5 Status P Date 2000-05-16 Cont ID  
Sent By tlarge Date 2000-05-16 Time 16:43 Rev Time 2.75
Received By tlarge Date 2000-05-16 Time 16:43 Sent To  
Notes
2001-01-08 00:00:00*******************PROVISO**************
  
 THE LAYOUT OF THE GREASY WASTE SYSTEM ON
 THE PLAN VIEW ON SHT.P-1 DOESN'T CORR-
 ELATE W/THE SANITARY RISER ON SHT.P-8.
  
 THE SIZE OF THE GREASE TRAP SHALL BE
 APPROVED BY THE CITY OF WEST PALM BEACH
 UTILITIES.CONTACT ROD COMPO AT
 (561)835-7423.SUBMIT APPROVAL FORM FROM
 UTILITIES.
  
 DISCHARGE FROM ELEVATOR SUMPS SHALL
 CONNECT TO THE SANITARY SYSTEM.
  
 WATER RISER-OVER 4 FIXTURE CONNECTED TO
 1/2"H.W.LINE.COUNTYWIDE AMENDMENTS TO
 SPC SEC.607.7.
  
 LINE SIZES ARE LACKING ON THE WATER
 RISER AND STORM RISER.
  
 SHT.8.1-10"STORM DRAIN DRAINING INTO 8"
 LINE.SEE RISER ST-5.SPC 709.1.

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-04-20 Cont ID  
Sent By tlarge Date 2000-04-20 Time 11:37 Rev Time 6.50
Received By tlarge Date 2000-04-20 Time 11:37 Sent To  
Notes
2001-01-08 00:00:00*****************PROVISO****************
 REVISED DRAWINGS SHOWING THE FOLLOWING
 CORRECTIONS SHALL BE SUBMITTED PRIOR TO
 ROUGH PLUMBING INSPECTION.
  
 1.)FLOORS AND WALLS IN TOILET ROOMS AND
 RESTROOMS SHALL BE NONABSORBENT MATERIAL
 TO A HEIGHT OF 4'PER SBC SEC.1204.2.
 (PLANS NOTE PAINT BUT NOT THE TYPE.)
  
 2.)PLUMBING PLANS REFER TO DRAWING
 MUV-CIT2.SUBMIT DRAWING FOR REVIEW.
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 3.)THE LAYOUT OF THE GREASY WASTE SYSTEM
 ON SHT.P1 DOESN'T CORRELATE W/SHT.P8.
  
 4.)SHT.P1-THE 6"SANITARY LINE IS DRAIN-
 ING INTO A 4" LINE.COMPLY W/SPC SEC.
 709.1
  
 5.)SHOW SQ.FOOT AREA DRAINED BY EACH
 DD,RD,& GD ON THE STORM WATER RISER.
 COMPLY W/SPC TABLES 1108.1,1108.2.
  
 6)WATER SUPPLY CONTROL SHALL COMPLY W/
 SPC SEC.610.4.1,610.4.2.
  
 7)WATER RISER LACKS PIPE SIZES.COMPLY W/
 W/SPC TABLE 607.1.
  
 8)CLEARLY SHOW CONTINUATION POINTS OF
 SANITARY SYSTEM TO UPPER LEVELS.THE
 EXTENSIONOF THE SOIL,WASTE AND VENT
 SYSTEMTO THE UPPER FLOORS IS VAGUE.
 COMPLY W/SPC 104.2.1.
  
 9)THE SIZE OF THE GREASE TRAP SHALL BE
 APPROVED BY THE CITY OF WEST PALM BEACH
 UTILITIES.CONTACT ROD COMPO AT
 (561)835-7423.

Review Stop P PLUMBING
Rev No 3 Status F Date 2000-04-04 Cont ID  
Sent By tlarge Date 2000-04-04 Time 10:10 Rev Time 0.00
Received By tlarge Date 2000-04-04 Time 10:48 Sent To  
Notes
2001-01-08 00:00:00PLANS SHALL BE REVIEWED AND APPROVED BY
 THE PALM BEACH COUNTY HEALTH DEPT.PRIOR
 TO REVIEW BY THIS DEPT.PER COUNTYWIDE
 AMENDMENTS TO SPC SEC.101.4.7.
  
 FLOORS AND WALLS TO A HEIGHT OF 4'SHALL
 BE NONABSORBENT MATERIAL.SHT.ID-5.1.
 NOTES PAINT,BUT NOT THE TYPE.COMPLY W/
 SBC 1204.2.(SEE RMS.113,113A.)
  
 PLANS SHALL BEAR THE CITY PLACE LANDLORD
 STAMP PRIOR TO REVIEW BY THIS DEPT.
  
 PLBG.SHEETS REFER TO CIVIL DRAWINGS FOR
 CONTINUATION OF WATER,SEWER,& STORM.
 SUBMIT THESE PLANS FOR REFERENCE.COUNTY-
 WIDE AMENDMENTS TO SPC 104.2.1.
  
 SHOW REQD.BACKFLOW PREVENTION DEVICE ON
 WATER RISER AND ON PLAN VIEW.SPC 104.2.1
  
 SUBMIT ISOMETRIC DRAWINGS FOR SUMP
 DISCHARGE LINES FROM ELEVATORS AND
 ESCALATORS.DRAINS MAY BE REQD.TO DIS-
 CHARGE THRU AN INTERCEPTOR PER SPC SEC.
 1004.1,1004.5.
  
 PLUMBING PLANS REFER TO DRWG.MUV-CIT2.
 CLARIFY AND SUBMIT THESE SHEETS IF
 APPLICABLE.COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.1.
  
 WATER HEATERS LOCATED ABOVE THE GROUND
 FLOOR SPACE SHALL HAVE A PAN WITH A
 DRAIN PER COUNTYWIDE AMENDMENTS SEC.
 507.8.1
  
 ALL FLOOR SINKS,FLOOR DRAINS,HAND SINKS
 ETC.LOCATED IN THE FOOD PREP AREA SHALL
 DRAIN TO THE GREASY WASTE SYSTEM.SPC SEC
 1004.1,1004.4.
  
 THE FIXTURE UNIT LOAD ON THE 4"BUILDING
 DRAIN EXCEEDS THE TOTAL ALLOWABLE LIMIT
 BY TABLE 714.1 OF SPC.
  
 LAYOUT OF U/G SANITARY ON SHT.P1 DOESN'T
 CORRELATE W/SHT.P8.COUNTY AMENDMENTS TO
 SPC SEC.104.2.1,AND THERE ARE FIXTURES
 MISSING ON THE RISER.(SEE RMS.130,131,
 MOP SINK.CHECK ALL RESTROOMS.)
  
 ISOMETRICS FOR MAIN CONCESSION AREAS DO
 NOT CORRELATE W/ FLOOR PLAN.CLARIFY.
 COUNTYWIDE AMENDMENT TO SPC SEC.104.2.1.
  
  
 REMOVE TRAP ON OSD LINE PER SPC SEC.
 1106.4.(SEE SHT.8.1)
  
 SHOW SQ.FT.AREA DRAINED BY EACH DD.
 COMPLY W/SPC TABLES 1108.1,1108.2.
  
 INDICATE TYPICAL DROP SIZE ON AIR RISER
 AND PIPE MATERIAL,SHOW VALVES.
  
 COMPRESSED AIR DRAWING ON P-5 AND P-9 DO
 NOT CORRELATE.CLARIFY.
  
 WATER SUPPLY CONTROL SHALL COMPLY W/SPC
 610.4.1,610.4.2.
  
 WATER RISER LACKS PIPE SIZES.CLEARLY
 SIZE RISER DIAGRAM & COMPLY W/SPC TABLE
 607.1.
  
 SHT.P9 SHOWS WATER SUPPLY EXTENDING
 BEYOND 4TH FLR.LEVEL.CLARIFY.
  
 SHTP9.1-WATER HEATERS INSTALLED ABOVE
 FIRST FLOOR SPACE SHALL BE EQUIPPED W/
 PANS AND PAN DRAINS PER COUNTYWIDE
 AMENDMENTS TO SPC SEC.507.8.1
  
 WATER HEATERS SHALL BE VALVED PER SPC.
 SEC.501.6,506.1.
  
 HOT WATER SHALL BE INSTALLED ON LEFT
 SIDE PER SPC SEC.601.10.
  
 A TWO WAY CLEANOUT SHALL BE INSTALLED
 ENTERING AND LEAVING EACH GREASE TRAP.
 SPC SEC.1004.2,710.4
  
 CLEARLY SHOW MATCH POINTS ON SANITARY
 RISERS TO FOUNDATION PLAN TO ENSURE
 DESIGN COMPLIES W/SPC.SEE PAGE P8.
  
 LABEL WATER RISERS ON P9.1 AS TO AREA.
 COUNTYWIDE AMENDMENTSTO SPC SEC.104.2.1.

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-02-27 Cont ID  
Sent By tlarge Date 2000-02-27 Time 10:46 Rev Time 0.00
Received By tlarge Date 2000-02-27 Time 10:46 Sent To  
Notes
2001-01-08 00:00:00*****CONTINUATION OF PLUMBING COMMENTS**
  
 SHT.P-2 SHOWS FIRE LINE CONNECTED TO
 DOMESTIC WATER LINE.LINES SHALL BE
 SEPARATE PER SPC SEC.601.2,601.5.
  
 PLUMBING PLANS REFER TO SHEETS MUV-CIT2.
 CLARIFY AND SUBMIT THESE SHEETS IF
 APPLICABLE.COUNTYWIDE AMENDMENTS SEC.
 104.2.1.
  
 WATER HEATERS LOCATED ABOVE 1ST.FLR.
 CEILING SHALL HAVE A PAN WITH A DRAIN
 PER COUNTYWIDE AMENDMENTS TO SPC SEC.
 507.8.1.PAN SHALL COMPLY W/SPC SEC.
 507.8.2.
  
  
 *******************NOTE*****************
 THE FOUNDATION PLANS WERE APPROVED BY
 PLUMBING PLAN REVIEW ON 10/1/99 WITH A
 PROVISO THAT CORRECT SANITARY,WATER,
 STORM AND CONDENSATE ISOMETRICS MUST BE
 SUBMITTED WITHIN 30 DAYS.TO DATE THESE
 ISOMETRICS HAVE NOT BEEN SUBMITTED FOR
 REVIEW.
  
 CALL (561)659-8096 IF YOU HAVE ANY
 QUESTIONS.TIMOTHY K.LARGE,PLANS EXAMINER

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-02-27 Cont ID  
Sent By tlarge Date 2000-02-27 Time 09:32 Rev Time 6.25
Received By tlarge Date 2000-02-27 Time 09:31 Sent To  
Notes
2001-01-08 00:00:00THE TOTAL NUMBER OF DRINKING FOUNTAINS
 REQD.IS 7 PER SPC TABLE 407 AND A MIN.OF
 1 SHALL BE LOCATED ON EACH FLOOR SUBJECT
 TO ACCESS.FOUNTAINS SHALL ALSO COMPLY W/
 FACBC SEC.4.1.3(10)(A)(B) AND 4.15.
 SUBMIT DETAIL OF H.C.DRINKING FOUNTAIN.
  
 THE TOTAL NUMBER OF WATER CLOSETS REQD.
 FOR THE MALES IS 9 AND A TOTAL OF 8 IS
 SUPPLIED.COMPLY W/SPC TABLE 407 FOR MIN.
 FIXTURE REQS.
  
 PLANS SHALL BE REVIEWED AND APPROVED
 BY THE PALM BEACH COUNTY HEALTH DEPT.
 PRIOR TO REVIEW BY THIS DEPT.PER COUNTY-
 WIDE AMENDMENTS TO SPC SEC.101.4.7.
 CALL (561)355-3018.
  
 SHT.A6.2-CLEARLY SHOW DEPTH OF HANDICAP
 STALL IN ROOM #131(WOMEN'S R.R.) AND
 SHOW HANDICAP STALL DOOR IN MEN'S R.R.
 (#130).
  
 MIN.CLEAR FLOOR SPACE UNDER H.C.LAVS
 FROM BOTTOM OF APRON TO F.F.IS 29"PER
 FACBC SEC.4.19.2.SHOW ON ELEVATION
 DETAILS.
  
 SHT.A6.2-HANDICAP URINAL SHALL BE IN-
 STALLED W/THE RIM NO HIGHER THAN 17"PER
 FACBC SEC.4.18.2 AND SHOW REQD.30"X48"
 CLEAR FLOOR ACCESS TO FIXTURE.
  
 CLEARLY SHOW LOCATION OF ALL DRINKING
 FOUNTAINS ON THE PLANS.COUNTYWIDE AMEND-
 MENTS TO SPC SEC.104.2.1.
  
  
  
  
 SHT.ID 3.13-HT. OF H.C. TOILET IN TOILET
 ROOMS 113,113A SHALL BE AT 17-19"PER
 FACBC SEC.4.16.3.
  
 SHT.A6.2-CLEARLY SHOW WIDTH OF H.C.
 TOILET ROOM.COMPLY W/FACBC SEC.4.16.2,
 4.19.3.
  
 INDICATE TYPE OF FINISH ON TOILET ROOM
 WALLS.COMPLY W/SBC 1204.2.(FINISH
 SCHEDULE NOTES PAINT BUT NOT TYPE.WALLS
 MUST BE NONABSORBENT TO A HEIGHT OF 4'.
  
 PLANS MUST BEAR CITY PLACE APPROVAL
 STAMPS FOR PERMITTING.
  
 UNISEX TOILET ROOMS CANNOT BE CONSIDERED
 IN COUNT FOR THE MIN.FIXTURE REQS.
 SEPARATE FACILITIES ARE REQD.PER SPC
 TABLE 407,FOOTNOTES #6 & #8.
  
 FLOOR DRAINS ARE REQD.IN ALL TOILET
 ROOMS PER SPC 409.4.4.1.
  
 PLUMBING SHEETS REFER TO CIVIL DWGS.FOR
 CONTINUATION OF PLUMBING LINES.SUBMIT
 CIVIL DWGS.FOR REVIEW OR PERMIT NUMBER
 OF CIVIL WORK.
  
 SUBMIT DETAIL OF GREASE INTERCEPTOR
 WITH ALL REQD.INFORMATION.THE SUBMITTED
 DETAIL DOESN'T CONTAIN ENOUGH INFO FOR
 PROPER REVIEW.COUNTYWIDE AMENDMENTS TO
 SPC SEC.104.2.1.CONTACT R.COMPO AT (561)
 835-7423 FOR INFORMATION REGARDING SIZE,
 DESIGN,ETC.
  
 SUBMIT A SANITARY,STORM,WATER AND CON-
 DENSATE ISOMETRIC THAT CLEARLY REFLECTS
 THE ENTIRE SCOPE OF WORK BEING DONE.THE
 ISOMETRICS SHALL MATCH THE PLAN VIEW
 DRAWINGS.THE SUBMITTED RISER DIAGRAMS
 ARE THE SAME FROM SEPT.1999 W/THE
 FOUNDATION ONLY PLANS.THEY WERE NOT
 ACCEPTABLE THEN AND ARE NOT ACCEPTABLE
 NOW.COUNTYWIDE AMENDMENTS TO SPC SEC.
 104.2.1.
  
 A BACKFLOW PREVENTION DEVICE IS REQD.ON
 THE DOMESTIC WATER SERVICE PER SPC SEC.
 606.
  
 SUBMIT ISOMETRICS FOR SUMP DISCHARGE
 LINES FROM ELEVATORS AND ESCALATORS,AND
 ALL COMPRESSED AIR PIPING.COUNTYWIDE
 AMENDMENTS TO SPC SEC.104.2.1.
  
 PLAN VIEW AND RISER DIAGRAMS SHOW
 SANITARY SYSTEM AND GREASY WASTE INTER-
 CONNECTED.COMPLY W/SPC SEC.1004.3