| Plan Review Stops For Permit 00020273 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-11-20 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-11-20 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-04-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-04-27 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************PROVISO************** | | | OK FOR PHASE ONE WORK [BUILDING] | | | | | | SUBMIT FLORIDA ENERGY CALCULATIONS, | | | PROVIDE PLUMBING INFORMATION, | | | REDESIGN CORRIDORS[434 AND 500]INCLUDE | | | DOORS[433 AND 509]FOR COMPLIANCE WITH | | | FL.ACC.CODE SECT. 4.13.6,MANUVERING | | | CLEARENCES | | | | | | | | | | | | REVIEWED BY; | | | LUIS MARTINEZ | | | 659-8096 #8456 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2001-03-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-07 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-07 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2001-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-01 |
Time |
19:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-01 |
Time |
19:49 |
Sent To |
|
|
| Notes |
| 2001-03-01 00:00:00 | HOLD UNTIL 2/5/01 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2000-10-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-10-10 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-10-10 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2000-07-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-27 |
Time |
20:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-27 |
Time |
20:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2000-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-27 |
Time |
19:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-27 |
Time |
19:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: PREVIOUS NOTES WERE NOT ADDRESS- | | | -ED. PLEASE NOTE THAT ALL REVISED PANEL | | | SCHEDULES AND LOAD CALCUALTIONS ARE TO | | | BE SIGNED AND SEALED BY ENGINEER OF | | | RECORD.REVISED LOAD CALCS AND PANELS | | | WERE FAXED. THIS IS WILL NOT BE ACCEPTED | | | THIS IS A STATE STATUE. | | | | | | 2)NOTE:PLEASE SUBMIT ELECTRICAL ROOM | | | DIMENSIONS. SHOW FOR ELECTRICAL CLEAR- | | | -ENCES FOR TRANFORMER AS PER 450-21 | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. PLANS THAT ARE SUBMITTED | | | ARE TO BE ATTACHED BY CONTRACTOR. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-06-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-22 |
Time |
20:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-22 |
Time |
20:46 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: AS PER OUR CONVERSATION. SHOWING | | | THE PANEL WITH FEED-THRU LUGS WAS FINE. | | | STILL NEED TO SHOW THE LOAD CALCULATIONS | | | COMPLETED AT THE BOTTOM OF EACH PANEL. | | | LIGHTING TO BE SHOWN AT 125 % | | | | | | 2)NOTE: FILL IN OUTLETS PER LOCAL CODE. | | | | | | 3)NOTE: PLEASE SEE ART 450-21-B FOR | | | TRANSFORMER REQ`MENTS. PLEASE GIVE EXACT | | | DIMENSIONS OF ELETRICAL ROOM WITH VERT. | | | AND HORIZONTALCLEARENCES. OO | | | | | | 4)NOTE: PLEASE COMPLETE THE LOAD CALCU- | | | LATION FOR LOAD ON MAIN "H". | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-03-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-03-25 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-03-25 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT ****************** | | | | | | 1)NOTE:SHOW LOAD CALCULATIONS;PLEASE | | | INCLUDE ALL CONTIUOUS LOADS(LIGHTING)ETC | | | NEED TO SHOW! | | | | | | | | | | | | | | | | | | | | | 3)NOTE; PLEASE CHECK ALL OUTLET SPACING | | | TO MEET LOCAL CODE. FOR OFFICE AND | | | STORAGE SPACE. 210-50 OF THE PALM BEACH | | | COUNTY /CITY AMENDMENTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2000-04-26 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-04-26 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-10-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-10-18 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-10-18 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-03-03 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-03-03 |
Time |
08:41 |
Rev Time |
0.15 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2000-10-17 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-10-17 |
Time |
17:57 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2000-10-17 |
Time |
17:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2000-08-23 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-08-23 |
Time |
11:46 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-08-23 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | OUTSIDE AIR AND AIR BALANCE CALCS ARE | | | ATTACHED TO SHELL FOR THIS ADDRESS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2000-07-25 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-25 |
Time |
12:05 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-25 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED: | | | AS PER REVIEW DONE ON 07.13.00 NO CHANGE | | | ON PLANS TO REVIEW ON 07.25.00. | | | PROVIDE OUTSIDE AIR CAL.. | | | PROVIDE AIR BALANCE SCHEDULE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2000-07-13 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-07-13 |
Time |
10:15 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-07-13 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************DENIED******************** | | | 1) PROVIDE OUTSIDE AIR CALCULATIONS | | | PER ASHRAE 62-89 | | | 2) PROVIDE AIR BALANCE SCHEDULE TO SHOW | | | COMPLIANCE WITH 1997 SMC 501.2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-03-10 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-03-10 |
Time |
14:15 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-03-10 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | MECH NOT REVIEWED********************8 | | | BUILDING CORE MECHANICAL SYSTEMS ARE | | | APPROVED FOR CODE COMPLIANCE | | | SYSTEM SHOWN AS EXISTING HAS TO BE APPR- | | | OVED PRIOR TO REVIEW OF ADDITIONAL | | | SYSTEMS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-29 |
Time |
17:10 |
Rev Time |
1.00 |
| Received By |
tlarge |
Date |
2000-08-29 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *******************PROVISO************** | | | | | | 1)THE CORE RESTROOMS ARE NON-COMPLIANT | | | PER SPC TABLE 407.CERTIFICATE OF | | | OCCUPANCY SHALL NOT BE ISSUED UNTIL THIS | | | MATTER IS RESOLVED.SEE PERMIT NUMBER | | | 99101414.TLARGE.8/29/00. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-29 |
Time |
08:46 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
2000-08-29 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)THE MINIMUM NUMBER OF WATER CLOSETS | | | REQD.FOR THE MALES BASED ON THE SQUARE | | | FEET OF HABITABLE FLOOR SPACE,OCCUPANT | | | LOAD AND TABLE 407 IS 4.(3 FOR THE FIRST | | | 150 PERSONS AND 1 FOR EACH ADDITIONAL | | | 100 PERSONS OR FRACTION THEREOF.) | | | | | | 2)FOR THE FEMALES-BASED ON THE SAME | | | DATA AND CRITERIA NOTED ABOVE,4 WATER | | | CLOSETS ARE REQD.FOR THE FIRST 150 | | | PERSONS,AND 1.5 FOR EACH ADDITIONAL 100 | | | PERSONS OR FRACTION THEREOF WHICH BRINGS | | | THE TOTAL NUMBER OF WATER CLOSETS REQD. | | | FOR THE FEMALES TO 6. | | | | | | 3)THE TOTAL NUMBER OF LAVATORIES REQD. | | | FOR THE FEMALES IS 3 FOR THE FIRST 125 | | | PERESONS AND 1.5 FOR EACH ADDITIONAL | | | 120 PERSONS OVER 125 WHICH BRINGS THE | | | TOTAL TO 5 LAVATORIES. | | | | | | ***NOTE:THESE REQS.ARE BASED UPON THE | | | THE FLOOR AREA CALCULATIONS SUBMITTED BY | | | COOPER CARRY DATED AUGUST 23,2000. | | | CALCULATIONS SHALL BE SUBMITTED FOR THE | | | DEDUCTED AREAS USED TO ARRIVE AT THE | | | PRESENT FIGURES.SEE SPC SEC.407.1.2. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-08-21 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-21 |
Time |
16:41 |
Rev Time |
0.65 |
| Received By |
tlarge |
Date |
2000-08-21 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | THE APPLICATION STILL NOTES 20,000 SQ. | | | FT.OF FLOOR SPACE.SUBMIT THE NUMBER OF | | | OCCUPANTS BASED ON THE SQUARE FEET OF | | | HABITABLE FLOOR SPACE.SEE SPC SEC. | | | 407.1.3.FOR ALLOWED DEDUCTIBLE AREAS. | | | COMPLY W/SPC TABLE 407 FOR MIN.PLUMBING | | | FIXTURE REQS. | | | | | | 2)SUBMIT DETAIL OF THE HANDICAP STALLS. | | | THERE IS AN ISSUE WITH THE STALLS BEING | | | NON-COMPLIANT THAT STEMS FROM MY REVIEW | | | OF REVISIONS FOR THE SHELL BUILDING. | | | STALLS SHALL COMPLY W/FACBC SEC.4.17.3. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-08-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-08-05 |
Time |
10:01 |
Rev Time |
2.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PLAN REVIEW, UNSAT | | | (1) SHT A-1 IS NOT THE MOST CURRENT COPY | | | OF THE COMMON AREA REST RM'S. | | | (2) PERMIT APPLICATION SHOWS 20,000 SQ. | | | FT.TAB 407 MIN FACILITIES, BUSSINESS | | | OCC.REQ'S 5-W/C'S & 5-LAV'S FOR WOMENS | | | REST RM, SPC 94. | | | (3) SHT A-8 ELEVATION DETAIL FOR RM 492 | | | FRONT APPROACH TO SINK, COMPLY W/FACBC | | | 4.24.5 S SHOW CLEAR FLR SPACE & KNEE | | | CLEARANCE. | | | END OF COMMENTS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-06-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-26 |
Time |
16:14 |
Rev Time |
1.50 |
| Received By |
pschmitz |
Date |
2000-06-26 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT SQUARE FOOT AREA OF OCCUPIED | | | SPACE.MINIMUM REQUIRED SANITARY | | | FACILITIES SHALL COMPLY W/SPC TABLE 407. | | | | | | CLEAR FLOOR SPACE FOR SINK IN ROOM 492 | | | SHALL BE CENTERED ON THE FIXTURE PER | | | FACBC SEC.4.24.5. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2000-04-26 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-04-26 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|