| Plan Review Stops For Permit 00011297 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2000-04-26 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-04-26 |
Time |
16:54 |
Rev Time |
2.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-04-04 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-04-04 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
bstaples |
Date |
2000-04-10 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. FLORIDA ENERGY SHEETS REQUIRED. | | | | | | 2. NOTES ADDED TO DRAWINGS MUST BE | | | APPROVED BY THE DESIGNER OF RECORD. | | | SEE SHEETS, A-0, A-0.1, A-1.2, A-4.0, | | | A-6.1, A-6.2, A-6.3, A-6.4, 3-3.0 AND | | | E-3.1. | | | | | | 3. SHEET A-6.4 PLANS DO NOT INDICATE | | | CODE COMPLIANCE FOR MISSLE IMPACT | | | PROTECTION. SEE 1997 STANDARD BUILDING | | | CODE AND CITY OF WEST PALM BEACH | | | AMENDMENTS (SSTD 12-97). | | | | | | 4. SHEET A-12 SECTION, N & N1 INDICATE | | | CONSTRUCTION OF ONLY ONE SIDE OF FIRE | | | SEPERATION. CITY POLICY REQUIRES | | | CONSTRUCTION OF BOTH SIDES OF THE WALL | | | REVISE NOTES AND SECTION. | | | | | | 5. FIRE SPRINKLER CONTRACTOR MUST APPLY | | | FOR A FIRE SPRINKLER PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-01-28 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-01-28 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
bstaples |
Date |
2000-03-21 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. CITYPLACE APPROVAL STAMP NOT ON PLANS | | | 2. SHEET A-0, CODE REFERENCES NOT | | | CORRECT, | | | MECHANICAL CODE IS 1997 NOT 1996 SBC | | | PLUMBING CODE IS 1994 NOT 1997 SBC | | | | | | KEY PLAN IS NOT INDICATING PROPER | | | LOCATION FOR UNIT. | | | UNIT ADDRESS LISTED IS NOT APPROVED FOR | | | USE BY CITY OR US POSTAL SERVICE. | | | 3. SHEET A-1.2 MEZZAINE NOT IN | | | COMPLIANCE WITH 1997 SBC SECTIONS 7, 10, | | | AND 11ALSO CHAPTER 16 FOR LOAD | | | INFORMATION. | | | 4. ESCULATORS SHALL COMPLY WITH CHAPTER | | | 7, 10 AND 30, 1997 SBC. | | | 5. SIGNS AND FIGURES REQUIRE SEPERATE | | | PERMITTING. | | | 6. SHEET A-6.4 PROVIDE PRODUCT APPROVALS | | | FOR ALL EXTERIOR WINDOWS AND DOORS, SEE | | | NOTE 24. | | | 7.ALL WOOD SHAL BE PRESSURE TREATED FIRE | | | RETARDANT LUMBER SBC 1997 SECTION707. | | | 8. SHEET A-03(3)&(4) INDICATE CHANGE IN | | | FLOOR ELEVATIONS, PROVIDE INFORMATION | | | ON PLAN INDICATING COMPLIANCE WITH 1997 | | | FL. HANDICAPPED CODE. | | | 9. INDICATE THE TOTAL HEIGHT OF | | | CONSTRUCTION ON PLANS. | | | PLAN REVIEW NOTES 1/28/00 | | | 10. DEMISING WALL SECOND FLOOR TO BE | | | 2 HOUR SEE TABLE 704.1 SEPERATION | | | ASSEMBLY TO MERCANTILE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2000-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-18 |
Time |
19:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-18 |
Time |
19:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-04-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-04-27 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-04-27 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NOTES STILL ON PLANS FOR COLOR CODING | | | OF FEEDERS 215 OF LOCAL AMENDMENTS . |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-04-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-04-10 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-04-10 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: STILL NEED TO SHOW GROUNDING | | | SYSTEM ON THE LINESIDE OF TRANSFORMER. | | | 215-5 | | | 2)NOTE:PLEASE MAKE NOTES ON PLANS THAT | | | COLOR CODING FOR FEEDERS ARE TO BE TO | | | LOCAL CODE.215 | | | | | | 3)NOTE:PLEASE INDICATE ON PLANS ALL LOAD | | | -S THAT ARE CONTINUOUS AT 125%. | | | SHOW IN LOAD CALCULATION FOR ALL | | | LIGHTING.ALSO MOTOR LOAD FOR THE TWO | | | CLOCK MOTORS.AND ANY OTHER LOADS. | | | 215-5/220-12/210-19A | | | | | | 4)NOTE: ALSO FOR 210-62 REQ`MENTS FOR | | | OUTLETS IN SHOW WINDOWS | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW.IF THERE ARE ANY QUESTIONS PLEASE | | | CALL 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-02-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-02-01 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-01 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************ NOTE********************** | | | | | | 1)NOTE: NEED TO SHOW GROUNDING ON THE | | | LINE SIDE OF TRANSFORMER. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2000-09-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-09-27 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-09-27 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-04-26 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-04-24 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | REVISED PLANS TO FIRE 4/24/00 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-02-01 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-02-01 |
Time |
11:19 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SEE NOTES ON PLANS M. CARSILLO LT.2/1/00 | | | ENGINEER DRAWINGS FOR FIRE SPRINKLER | | | REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2000-09-09 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-09-09 |
Time |
07:59 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-09-09 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | AS BUILT DRAWINGS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-05-03 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-05-03 |
Time |
10:30 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2000-05-03 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PRIOR COMMENTS CORRECTED BY REVISIONS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2000-04-11 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-04-11 |
Time |
07:05 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-04-11 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************DENIED********************* | | | | | | 1) AIR BALANCE REQUESTED NOT PROVIDED: | | | OUTSIDE AIR PROVIDED ON PLAN EQUALS | | | 4955 CFM | | | LESS BATH EXHAUST OF 200 CFM = 4755 CFM | | | LESS 4952 CFM RELIEF VENTILATOR=-197CFM | | | WHICH WOULD PUT BUILDING IN A NEGATIVE | | | PRESSURE. | | | PROVIDE CORRECTED AIR BALANCE SHOWING | | | OUTSIDE AIR AND EXHAUST AIR BALANCE, | | | INCLUDING EXFILTRATION, RELIEF AND | | | EXHAUST AIR FIGURES. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-01-31 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-01-31 |
Time |
15:04 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-01-31 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************DENIED******************** | | | 1) PROVIDE OUTSIDE AIR CALCULATIONS PER | | | ASHRAE 62-89 | | | 2) PROVIDE AIR BALANCE CALCULATIONS PER | | | 1997 SMC 501.2 | | | 3) NOTE: NO COMBUSTIBLE MATERIALS ALLOW- | | | ED IN PLENUM AREAS PER 1997 SMC 609.1.2 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2000-10-07 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-07 |
Time |
07:40 |
Rev Time |
1.00 |
| Received By |
tlarge |
Date |
2000-10-07 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
N |
Date |
2000-09-22 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-22 |
Time |
14:24 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-09-22 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING NOT AFFECTED THIS REVISION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2000-05-09 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-05-09 |
Time |
10:15 |
Rev Time |
1.50 |
| Received By |
tlarge |
Date |
2000-05-09 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-05-02 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-05-02 |
Time |
20:02 |
Rev Time |
1.25 |
| Received By |
tlarge |
Date |
2000-05-02 |
Time |
20:02 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLANS SHALL BE SEALED BY THE | | | DESIGN PROFESSIONAL OF RECORD PER | | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.3 | | | | | | DRINKING FOUNTAINS SHALL COMPLY W/FACBC | | | SEC.4.1.3.(10)(A).PROVISIONS SHALL BE | | | MADE FOR PEOPLE WHO USE WHEELCHAIRS AND | | | FOR THOSE WHO HAVE TROUBLE BENDING OR | | | STOOPING.INDICATE MEANS OF COMPLIANCE ON | | | PLANS. | | | | | | INDICATE OCCUPANT LOAD ON PLANS FOR | | | DETERMINATION OF MINIMUM SANITARY REQS. | | | SEE SPC SEC.407.1.3.FOR ALLOWED DEDUCT- | | | IBLE AREAS AND COMPLY W/SPC TABLE 407. | | | (PLUMBING FIXTURES ARE NOT ADEQUATE FOR | | | SPECIFIED OCCUPANT LOAD.) | | | | | | URINAL SHALL BE LOCATED TO ENSURE USER | | | PRIVACY PER SPC SEC.404.3.(FIXTURE IS | | | LOCATED IN LINE OF SIGHT FROM CORRIDOR.) | | | | | | WET VENTS SHALL RECEIVE THE DISCHARGE | | | FROM FIXTURE DRAINS ONLY PER COUNTYWIDE | | | AMENDMENTS TO SPC SEC.911.1.1. | | | | | | DRY VENTS NOT PERMITTED PER SPC SEC. | | | 901.2,906.2. | | | | | | CLARIFY TERMINATION PT.OF RELIEF DRAIN | | | FOR EWH.PLANS NOTE TO EXTERIOR AND ALSO | | | TO MOP SINK.EITHER IS ACCEPTABLE PER SPC | | | | | | CLEANOUTS ARE REQD.IN HORIZONTAL | | | DRAINAGE PIPE PER SPC SEC.710.2.1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-04-06 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-04-06 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
tlarge |
Date |
2000-04-06 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | URINAL SHALL COMPLY W/FACBC SEC.4.18.2 | | | THRU 4.18.4 | | | | | | WATER SUPPLY CONTROL SHALL COMPLY W/ | | | SPC SEC.610.4.1,610.4.2. | | | | | | DRINKING FOUNTAIN ON 1ST.FLR.SHALL BE | | | ACCESSIBLE TO THE PUBLIC PER SPC SEC. | | | 407.2.2.AND COMPLY W/FACBC SEC.4.15. | | | | | | SUBMIT A SANITARY RISER DIAGRAM THAT | | | COMPLIES W/THE STANDARD PLUMBING CODE. | | | | | | WATER HEATER SHALL BE READILY ACCESSIBLE | | | PER SPC SEC.501.7.(SUPPLY A PERMANENT | | | LADDER OR RELOCATE EWH TO FLOOR.)++ | | | | | | T & P VALVE DRAIN SHALL DISCHARGE TO | | | EXTERIOR PER COUNTYWIDE AMENDMENTS TO | | | SPC SEC.507.8.4. | | | | | | ALL PUBLIC AND COMMON USE AREA TOILET | | | ROOMS SHALL COMPLY W/FACBC SEC.4.1.3(11) | | | | | | CLEARLY SHOW DIMENSIONS (L X W) OF | | | HANDICAP TOILET STALLS.COMPLY W/FACBC | | | SEC.4.17.3 EXCEPTION :NEW CONSTRUCTION. | | | | | | DRINKING FOUNTAIN ON 2ND.FLR.SHALL | | | COMPLY W/FACBC SEC.4.1.3.(10)(A) | | | | | | WATER HEATERS SHALL BE EQUIPPED W/PANS | | | AND DRAINS PER COUNTYWIDE AMENDMENTS TO | | | SPCSEC.507.8.1,507.8.3. | | | | | | CLARIFY USE OF ROOM CONTAINING DOUBLE | | | SINK.IF THIS ROOM IS A BREAKROOM THE | | | SINK SHALL COMPLY W/FACBC SEC.4.24.1- | | | 4.24.7. | | | | | | CLEARLY SIZE ALL VENTS ON SANITARY RISER | | | COMPLY W/SPC TABLE 920.2,920.4. | | | | | | VENTING OF WATER CLOSETS SHALL COMPLY W/ | | | SPC SEC.906.2.1.,906.2.2. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-01-31 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-01-31 |
Time |
09:42 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
2000-01-31 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CITY PLACE APPROVAL REQD.ON PLANS. | | | | | | SHT.A-0-THE ADOPTED PLBG.CODE IS | | | STANDARD PLUMBING CODE 1994 EDITION. | | | | | | SHT.A-5.3-SHOW MOUNTING HEIGHTS AND | | | FIXTURE CLEARANCES OF PLUMBING FIXTURES | | | AND ACCESSORIES.COMPLY W/FACBC. | | | | | | SHOW TURNING SPACE FOR WHEELCHAIR IN | | | TOILET ROOMS PER FACBC SEC.4.2.3. | | | | | | MINIMUM TOILET FACILITIES SHALL COMPLY | | | W/SPC SEC.407.1.4. | | | | | | WATER SUPPLY CONTROL SHALL COMPLY W/SPC | | | SEC.610.4.1. | | | | | | A DRINKING FOUNTAIN IS REQD.ON THE 1ST. | | | AND SECOND FLOOR PER SPC TABLE 407. | | | | | | A VENT SHALL BE LOCATED BETWEEN THE TWO | | | WATER CLOSETS AND COMPLY W/COUNTYWIDE | | | AMENDMENTS TO SPC SEC.911.1.3. | | | | | | WATER HEATER SHALL BE READILY ACESSIBLE | | | PER SPC SEC.501.7.(A PERMANENTLY | | | INSTALLED LADDER IS REQD.OR RELOCATE | | | EWH TO FLOOR.) | | | | | | T & P VALVE DRAIN TERMINATION SHALL | | | COMPLY W/COUNTYWIDE AMENDMENTS TO SPC | | | SEC.507.8.4. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-04-18 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-02-01 |
Time |
11:20 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLAN REVIEW NO ZONING APPROVAL |
|
|