Plan Review Details - Permit 00010846
| Plan Review Stops For Permit 00010846 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-08-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-08-19 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-03-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-03-01 |
Time |
06:50 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-29 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-29 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE SHOW MORE DETAIL ON FIX- | | | -TURES BEING ADDED??? CIRCUIT #`S | | | AND FIXTURES ON PLANS. ALSO PLEASE NOTE | | | THAT PLANS ARE TO BE SIGNED AND SEALED | | | BY THE ARCHITECT OF RECORD. | | | | | | 2)NOTE: PLEASE ALSO NOTE THAT PERMIT | | | VALUE IS TO BE INCREASE FOR ADDITIONAL | | | WORK. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-03 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-03 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-02-12 |
Time |
19:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-12 |
Time |
19:05 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************* PROVISO ***************** | | | | | | 1)NOTE:SEE PAGE5-EL-DET FOR NOTES ON THE | | | REQ`MENTS OF COLOR CODING WIRING, | | | AS PER PALM BEACH COUNTY AMENDMENTS; | | | ART;215IF ANY FEEDERS ARE TO BE | | | INSTALLED, THEN THEY MUST MEET THAT | | | COLORING CODE. PLEASE LIST ADDITIONAL | | | NOTE FOR FEEDER CONDUCTORS. | | | THERE IS AN EXCEPTION. THE EXISTING | | | SYSTEN OF COLOR CODING MAY BE MAINTAINED | | | FOR COMMERCIAL AND INDUSTRIAL INSTALL- | | | -ATIONS. | | | | | | | | | | | | | | | 2)NOTE: PLEASE SHOW IN MORE DETAIL THE | | | EXISTING PANELS/ AND PANEL SCHEDULES. | | | | | | | | | PLEASE NOTE THAT BEFORE ANY FINAL | | | INSPECTION IS CALLED, YOU WILL NEED TO | | | SUBMIT ALL NEW PANEL SCHEDULES. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-04-26 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-04-26 |
Time |
09:17 |
Rev Time |
0.20 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-01-19 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-01-19 |
Time |
15:17 |
Rev Time |
0.45 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-02-01 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-02-01 |
Time |
07:54 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-02-01 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-02-05 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-02-05 |
Time |
08:29 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-02-05 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-02-02 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-02-02 |
Time |
16:00 |
Rev Time |
1.25 |
| Received By |
tlarge |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | THE DIMENSIONS FOR THE HANDICAP | | | ACCESSIBLE TOILET STALLS SHALL COMPLY W/ | | | FACBC SEC.4.17.3,SPC 403.1.(MIN.84"WIDE) | | | | | | SIZE SANITARY AND WATER LINES.COMPLY W/ | | | SPC 607,SPC TABLES 714.1,714.2 |
|
|
|