Plan Review Details - Permit 00010822
Plan Review Stops For Permit 00010822
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-07-27 Cont ID  
Sent By lmartine Date 2000-07-27 Time 11:27 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-02-03 Cont ID  
Sent By lmartine Date 2000-02-03 Time 10:19 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-03-11 Cont ID  
Sent By dpalmer Date 2001-03-11 Time 12:07 Rev Time 0.00
Received By dpalmer Date 2001-03-11 Time 12:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-03-06 Cont ID  
Sent By dpalmer Date 2001-03-06 Time 16:24 Rev Time 0.00
Received By dpalmer Date 2001-03-06 Time 16:24 Sent To  
Notes
2001-03-06 00:00:00***************** UNSAT ****************
  
 1)NOTE: PLEASE SHOW ALL BRANCH CIRCUIT`S
 ON PLANS AND CORRELATE WIH PANEL SCHED-
 -ULR.
  
 2)NOTE: PLEASE NOTE THAT ELECTRICAL
 RISER DIAGRAM AND PANELS DO NOT MATCH,
 ONE SHOWS 200A AND THE OTHER 225A WITH
 WIRE RATED FOR 200A??
  
 3)NOTE: PLEASE LABEL ALL BRANCH CIRCUIT
 #`S ON PLANS THAT CORRELATE WITH SUBMITT
 ED PANEL SCHEDULES
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-07-11 Cont ID  
Sent By dpalmer Date 2000-07-11 Time 18:47 Rev Time 0.00
Received By dpalmer Date 2000-07-11 Time 18:46 Sent To  
Notes
2001-01-08 00:00:00***************** PROVISO *************8
  
 1)NOTE: PLEASE SUBMIT THE AIC RATING OF
 MAIN. MUST BE RATED FOR THE AVAILABLE
 FAULT CURRENT. 110-9
  
 BEFORE INSPECTION.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2000-07-14 Cont ID  
Sent By mgonzale Date 2000-07-14 Time 14:26 Rev Time 2.00
Received By mgonzale Date   Time   Sent To  
Notes
2001-01-08 00:00:00PASSED WITH PROVISOS
 1.0
 THE WATER METER MUST BE READABLE OR
 ACCESSABLE.
 2.0
 FOUNTAIN IN THE WALL DOES NOT STATE
 WHERE THE WATER WILL BE DISCHARGED TO
 BUT ALL WATER USED IN THE SITE MUST
 DISCHARGE INTO THE SANITARY SEWER
 3.0
 DUMPSTERAREA MUST ENCLOSED PER OUR
 DUMPSTER DETAIL AND STANDARDS ATTACHED.
 4.0
 DUMPSTER AREA MUST NOT BE BLOCKED AT ANY
 TIME NOR IT CAN BE USED FOR LOADING AREA

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-07-13 Cont ID  
Sent By rturnque Date 2000-07-13 Time 09:23 Rev Time 0.20
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-07-12 Cont ID  
Sent By cthirben Date 2000-07-12 Time 10:11 Rev Time 0.00
Received By cthirben Date 2000-07-12 Time 10:17 Sent To  
Notes
2001-01-08 00:00:00NOTES:**********************************
 NO MECHANICAL PLANS SUBMITTED FOR REVIEW
 ADDITIONAL PLANS REQUIRED FOR MECHANICAL
 WORK TO BE DONE.

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-09-02 Cont ID  
Sent By tlarge Date 2000-09-02 Time 07:54 Rev Time 0.25
Received By tlarge Date 2000-09-02 Time 07:52 Sent To  
Notes
2001-01-08 00:00:00ENGINEER TO SUBMIT LETTER TO ENGINEERING
 DEPT.PRIOR TO FINAL.

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-08-03 Cont ID  
Sent By tlarge Date 2000-08-03 Time 09:57 Rev Time 0.65
Received By tlarge Date 2000-08-03 Time 09:57 Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
 SUBMIT MANUF.SHEETS FOR GAS LIGHTS PRIOR
 TO GAS INSPECTION.SGC 402.1.

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-07-29 Cont ID  
Sent By tlarge Date 2000-07-29 Time 14:14 Rev Time 0.50
Received By tlarge Date 2000-07-29 Time 14:14 Sent To  
Notes
2001-01-08 00:00:00COMPLY W/ATTACHED LIST FOR GAS REQS.
  
 A WATER USE PERMIT FROM SFWMD IS REQD.
 PRIOR TO ISSUANCE OF IRRIGATION PERMIT.
 F.S.373.219.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-07-12 Cont ID  
Sent By tlarge Date 2000-07-12 Time 07:15 Rev Time 0.75
Received By pschmitz Date 2000-07-12 Time 06:58 Sent To  
Notes
2001-01-08 00:00:00SUBMIT DETAIL OF FILL LINES FOR
 FOUNTAINS.
  
 SHOW SIZE OF WELL ON PLANS.A WELL PERMIT
 AND WELL DRILLING PERMIT IS REQUIRED
 FROM SO.FLA.WATER MNGMT.DISTRICT PER
 FLA.STATUTE 373.
  
 A WATER USE PERMIT IS REQUIRED FROM SO.
 FLA WATER MNGMT.DISTRICT FOR THE WELL
 PER FLA.STATUTE 373.
  
 PLANS REFER TO MODIFICATION OF EXISTING
 GAS LINE ON SITE.SUBMIT DETAILS FOR THIS
 WORK.
  
 SUBMIT DETAIL OF OVERFLOW LINES FROM
 POOLS/FOUNTAINS TO SOAKAGE PIT.
  
 SHOW SIZE OF FUTURE RWL AND SQ.FT.AREA
 OF ROOF BEING DRAINED.COMPLY W/SPC SEC.
 1108.1,1108.2.
  
 INDICATE IF IRRIGATION SYSTEM IS EXIST.
 OR IF NEW.IF NEW,SUBMIT PLANS FOR
 SYSTEM.COUNTYWIDE AMENDMENTS TO SPC SEC.
 104.2.1.
  
 ***********ADDENDUM TO COMMENTS*********
 SUBMIT MANUF.SHEETS FOR ALL GAS EQUIP.
 EQUIPMENT SHALL BE LISTED PER SGC SEC.
 402.
  
 SEE ATTACHED LIST FOR GAS REQUIREMENTS.

Review Stop Z ZONING
Rev No 2 Status P Date 2000-07-18 Cont ID  
Sent By gjoyce Date 2000-07-18 Time 13:59 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00OK PER JIM SNAY

Review Stop Z ZONING
Rev No 1 Status P Date 2000-06-30 Cont ID  
Sent By gjoyce Date 2000-02-14 Time 08:31 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00NEEDS HISTORICAL AND A FORMAL SITE PLAN
 REVIEW