Plan Review Details - Permit 00010688
Plan Review Stops For Permit 00010688
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-04-20 Cont ID  
Sent By lmartine Date 2000-04-20 Time 16:05 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-03-30 Cont ID  
Sent By dpalmer Date 2000-03-30 Time 16:59 Rev Time 0.00
Received By dpalmer Date 2000-03-30 Time 16:59 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-01-25 Cont ID  
Sent By rturnque Date 2000-01-25 Time 09:45 Rev Time 0.15
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-04-21 Cont ID  
Sent By cthirben Date 2000-04-01 Time 07:38 Rev Time 1.00
Received By ndenmark Date 2000-04-12 Time 09:23 Sent To  
Notes
2001-01-08 00:00:00 
  
 ******************DENIED****************
  
 1. OUTSIDE AIR CALCULATIONS REQUIRED PER
 ASHRAE 62-89
 2. NOTE: MEDICAL (DENTAL) AIR OR VACUUM
 REQUIRES MECH PERMIT SUBMIT PLANS W/
 PERMIT APPLICATION PRIOR TO ANY WORK
 BEING DONE ON THIS SYSTEM

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-04-21 Cont ID  
Sent By ndenmark Date 2000-02-01 Time 11:00 Rev Time 1.00
Received By ndenmark Date 2000-02-01 Time 11:00 Sent To  
Notes
2001-01-08 00:00:00PROVIDED BY ENGINEER **************
 PROVIDE INFO ON CONNECTION WITH EXISTING
 OFFICE
 MEDICAL GAS REQUIRES MECHANICAL PERMIT
 PROVIDE PLANS WITH MECHANICAL PERMIT
 APPLICATION COMPLIANCE WITH NFPA 99C REQ
 EXISTING DUCT TO BE REUSED TO BE INSPECT
 ED FOR CLEANLINESS AND CLEANED AND SANI-
 TIZED BY LICENSED MECH CONTRACTOR IF
 DEEMED NECESSARY

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-04-01 Cont ID  
Sent By tlarge Date 2000-04-01 Time 08:11 Rev Time 0.50
Received By tlarge Date 2000-04-01 Time 08:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-02-01 Cont ID  
Sent By tlarge Date 2000-02-01 Time 14:00 Rev Time 0.65
Received By tlarge Date 2000-02-01 Time 14:00 Sent To  
Notes
2001-01-08 00:00:00FLOOR DRAIN W/TRAP PRIMER REQD.IN TOILET
 ROOM PER SPC SEC.409.4.1.1.
  
 TUB SHALL COMPLY W/FACBC SEC.4.20.1 THRU
 4.20.7.
  
 SINK SHALL COMPLY W/FACBC SEC.4.24.1-
 4.24.7.
  
 SUBMIT WATER RISER FOR REVIEW.
  
 LOCATION OF PLBG.FIXTURES ON SANITARY
 RISER SHALL MATCH FLOOR PLAN.