Plan Review Details - Permit 00010655
Plan Review Stops For Permit 00010655
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-05-11 Cont ID  
Sent By lmartine Date 2000-05-11 Time 11:43 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-02-15 Cont ID  
Sent By lmartine Date 2000-02-15 Time 12:56 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-05-11 Cont ID  
Sent By dpalmer Date 2000-05-11 Time 19:19 Rev Time 0.00
Received By dpalmer Date 2000-05-11 Time 19:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-01-22 Cont ID  
Sent By dpalmer Date 2000-01-22 Time 12:21 Rev Time 0.00
Received By dpalmer Date 2000-01-22 Time 12:21 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT *****************
  
 1)NOTE;NO ELECTRICAL PLANS SHOWN.
 NEED TO SHOW ALL SWITCH/REC HIEGHTS FOR
 ADA REQ`MENTS.
  
 PLEASE SUBMIT ELECTRICAL PLANS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-01-27 Cont ID  
Sent By rturnque Date 2000-01-27 Time 15:43 Rev Time 0.20
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-06-02 Cont ID  
Sent By cthirben Date 2000-06-02 Time 07:21 Rev Time 0.50
Received By cthirben Date 2000-06-02 Time 07:20 Sent To  
Notes
2001-01-08 00:00:00*****************NOTES******************
 NO MECCHANICAL PLANS SUBMITTED AT TIME
 OF REVIEW.

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-06-01 Cont ID  
Sent By tlarge Date 2000-06-01 Time 18:38 Rev Time 0.50
Received By tlarge Date 2000-06-01 Time 18:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-05-18 Cont ID  
Sent By tlarge Date 2000-05-18 Time 10:37 Rev Time 0.75
Received By tlarge Date 2000-05-18 Time 10:36 Sent To  
Notes
2001-01-08 00:00:00ALL PUBLIC AND COMMON AREA TOILET ROOMS
 SHALL BE FULLY ACCESSIBLE PER FACBC SEC.
 4.1.3.(11).
  
 DOORS CANNOT SWING INTO CLEAR FLOOR
 SPACE REQD.FOR FIXTURES PER FACBC SEC.
 4.22.2.
  
 SUBMIT WATER RISER FOR REVIEW PER COUNTY
 WIDE AMENDMENTS TO SPC SEC.104.2.1.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-01-18 Cont ID  
Sent By tlarge Date 2000-01-18 Time 08:55 Rev Time 0.00
Received By tlarge Date 2000-01-18 Time 08:54 Sent To  
Notes
2001-01-08 00:00:00SUBMIT WATER RISER DIAGRAM FOR REVIEW
 PER COUNTYWIDE AMENDMENTS TO SPC SEC.
 104.2.1.
  
 SHOW SQ.FT.OF BUILDING AND OCCUPANT
 LOAD PER SPC 407.
  
 SIZING OF VENT SYSTEM SHALL COMPLY W/SPC
 TABLE 920.2.
  
 MIN.SIZE OF DRAIN UNDERGROUND SHALL BE
 2" PER SPC SEC.714.4.
  
 UNDERGROUND SANITARY DRAINAGE SYSTEM
 SHALL BE SIZED PER SPC SEC.714.1,714.2.
  
 WATER CLOSET IN TODDLER'S AREA NOT
 PROPERLY VENTED.SPC SEC.901.2.
  
 A CLEANOUT IS REQD.IN THE BLDG.DRAIN PER
 SPC SEC.710.2.2.
  
 SHOW FIXTURE CLEARANCE OF HANDICAP WATER
 CLOSET FROM WALL AND LAVATORY.COMPLY W/
 FACBC FIGURE 28.
  
 PLANS SHOW A COOKING RANGE AND 3-COMP.
 SINK.IF FOOD PREPARATION/COOKING IS
 BEING DONE A GREASE TRAP WILL BE REQD.
 FOR THE SANITARY SYSTEM PER SPC SEC.
 1004.1 CONTACT ROD COMPO AT CITY OF WPB
 UTILITIES AT (561)835-7423.