Plan Review Details - Permit 00010371
Plan Review Stops For Permit 00010371
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2000-06-29 Cont ID  
Sent By dpalmer Date 2000-06-29 Time 13:04 Rev Time 0.00
Received By dpalmer Date 2000-06-29 Time 13:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-03-20 Cont ID  
Sent By dpalmer Date 2000-03-20 Time 07:51 Rev Time 0.00
Received By dpalmer Date 2000-03-20 Time 07:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-02-12 Cont ID  
Sent By dpalmer Date 2000-02-29 Time 14:36 Rev Time 0.00
Received By dpalmer Date 1900-02-12 Time 14:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-02-05 Cont ID  
Sent By dpalmer Date 2000-02-05 Time 17:40 Rev Time 0.00
Received By dpalmer Date 2000-02-05 Time 17:40 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT *****************
  
 1)NOTE: NEED TO SUBMIT AIC RATING OF
 EQUIPMENT MAINS. MAINS ARE TO BE RATED
 FOR AVAILABLE FAULT CURRENT.AS REQ`D BY
 ARTS:110-9/110-10 AND 215-5 OF THE NEC.
  
 2)NOTE:PLEASE HAVE THE DEDICATED BATH(S)
 CIRCIUT(S) LISTED ON PANEL SCHEDLUE.
  
 AIC RATING MUST BE ON ALL PLANS! THIS
 HAS BEEN PREVIOUSLY REQUESTED. PLEASE
 HAVE ALL THE ABOVE INFORMATION SUBMITTED
 FOR REVIEW AND APPROVAL.IF THERE ARE ANY
 QUESTIONS PLEASE CALL 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-01-22 Cont ID  
Sent By jleech Date 2000-01-22 Time 12:00 Rev Time 0.35
Received By jleech Date 2000-01-22 Time 12:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-07-07 Cont ID  
Sent By tlarge Date 2000-07-07 Time 15:20 Rev Time 0.25
Received By tlarge Date 2000-07-07 Time 15:20 Sent To  
Notes
2001-01-08 00:00:00REVISED PLBG.RISER.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-01-13 Cont ID  
Sent By tlarge Date 2000-01-13 Time 07:18 Rev Time 0.50
Received By tlarge Date 2000-01-13 Time 07:18 Sent To  
Notes
2001-01-08 00:00:00*****************PROVISO****************
 SANITARY RISER DOESN'T MATCH FLOOR PLAN.
 SUBMIT NEW SANITARY RISER PRIOR TO RGH.
 PLBG.INSP.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-03-27 Cont ID  
Sent By jcaloger Date 2000-03-07 Time 17:05 Rev Time 0.50
Received By jcaloger Date   Time   Sent To  
Notes
2001-01-08 00:00:00PLANS NOT DESIGNED TO THE 1997 SBC.
 NOTES THROUGHOUT PLANS REFERENCE 94 EDI-
 TION.
  
 FILL OUT THE HEADING OF THE DESIGN COMPL
 IANCE FORM.PROVIDE ADDRESS.
  
  
 TYPICAL WALL SECTION REFERS TO THE
 INVALID SSTD 10-93.CANNOT MIX DESIGN
 CRETERIA WITH SBC 1606 & SSTD.
  
 PLAN #1, HURRICANE INSTALTION SCHEDULE
 SPECIFYS THATTHE GARAGE OVERHEAD DOOR
 WILL SERVE AS A MEANS OF EGRESS.NOTE
 THATALL EGRESS DOORS ARE REQUIRED TO
 BE SWING TYPE.CLARIFY
  
 PLANS ARE REQUIRED TO BE SPECIFIC.
 PROVIDE THE ADDRESS ON THE PLANS
  
  
  
 ROOF TILE PRODUCT APPROVAL, THE PALM
 BEACH COUNTY CHECK LIST IS INVALID SINCE
 THE TILES HAVE A METRO DADE APPROVAL AND
 MUST BE INSTALLED ACCORDING TO.
  
  
 ROOF TILE, SPECIFY THE METHOD OF ATTACH-
 MENT.IF NAIL ON SYSTEM IS TO BE USED
 THAN PROVIDE THE CALCULATIONS.SEE PAGE
 10 OF THE PRODUCT APPROVAL.
  
  
 NORANDEX PRODUCT APPROVAL IS REQUIRED TO
 HAVE THE DESIGNER OF RECORD RAISED SEAL.
  
 MANUAL J CALCULATIONS, PROVIDE UPDATED
 CALCULATIONS.NOTE THAT WHITE OUT
 CHANGES WILL NOT BE ACCEPTED.
  
 HURRICANE SHUTTERS, PROVIDE A INSTALLAT-
 ION SCHEDULE AND PLAN IDENTIFYING THE
 OPENINGS.
  
 FILL OUT THE HEADING INFORMATION
 COMPLETELY ON THE ENERGY FORM 600

Review Stop Z ZONING
Rev No 1 Status P Date 2000-01-12 Cont ID  
Sent By gjoyce Date 2000-01-12 Time 09:27 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***