| Plan Review Stops For Permit 00010279 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-07-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-31 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-31 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-03-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-03-22 |
Time |
07:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-03-22 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** PROVISO **************** | | | | | | SUBMIT NEW REDRAWN SHEET BEFORE ANY | | | ROUGH INSPECTION IS CALLED IN. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-02-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-02-05 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-05 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: NEED TO SUBMIT AIC RATING OF | | | EQUIPMENT MAINS. MAINS NEED TO BE RATED | | | FOR THE AVAILABLE FAULT CURRENT.AS REQ`D | | | BY ARTS;110-9/110-10 AND 215-5 OF THE | | | NEC. | | | | | | 2)NOTE:AS REQ`D BY NFPA-72 2-2.1.1.1 | | | SMOKE DETECTORS ARE REQ`D INSDIE AND | | | OUTSIDE ALL SLEEPING ROOMS. | | | | | | 3)NOTE:PLEASE HAVE THE DEDICATED BATH(S) | | | CIRCUT(S) LISTE ON PANEL SCHEDULE. MUST | | | BE 20 AMP AND #12 AWG. THIS IS REQ`D BY | | | ART;210-52D | | | | | | 4)NOTE: NEED TO HAVE OUTLET MARKED ON | | | WALL BY FRONT DOOR PER 210-52 OR 210-52H | | | | | | PLEASE NOTE A/C AND METER LOCATION AND | | | CLEARANCES REQ`D BY 110-16 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW AND APPROVAL.IF THERE ARE ANY | | | QUESTIONS PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-01-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-01-25 |
Time |
15:37 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-01-25 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-01-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-01-24 |
Time |
13:38 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2000-01-24 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED; | | | 1. A/C UNIT NOT LARGE ENOUGH. LIVING | | | AREA 2056SQ FT. AND 1775CFMS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2000-10-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-26 |
Time |
11:36 |
Rev Time |
0.25 |
| Received By |
tlarge |
Date |
2000-10-26 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | REVISED SANITARY RISER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-02-19 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-02-19 |
Time |
09:31 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-02-19 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2000-02-19 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-01-13 |
Time |
09:49 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-01-25 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT A SANITARY ISOMETRIC THAT | | | COMPLIES W/SPC. | | | SEC.901.2 | | | TABLE 714.1.FOOTNOTE #3. | | | 409.12.3. | | | DRY VENTS NOT PERMITTED, |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2000-03-08 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-03-08 |
Time |
10:01 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-03-07 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ****************PROVISO***************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COPIES OF SBCCI OR | | | METRO-DADE PRODUCT APPROVALS FOR FRONT | | | DOOR ASSEMBLY WITH SIDELITE. | | | | | | 2)PROVIDE 2 CURRENT COPIES OF SBCCI OR | | | METRO-DADE PRODUCT APPROVALS FOR FIX | | | GLASS WINDOWS. | | | | | | 3)PROVIDE MISSILE IMPACT PROTECTION | | | INFORMATION WITH PERMIT APPLICATION. | | | | | | 4)PROVIDE ROOF COVERING PRODUCT APPROVAL | | | WITH PERMIT APPLICATION. | | | | | | PLEASE SUBMIT PRIOR TO INSTALLATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-01-10 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-01-10 |
Time |
15:26 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|