| Miscellaneous Information / Notes |
| CONSTRUCTION OF A RETAIL SHELL BUILDING |
| |
| |
| 7/20/23 REVIEWS COMPLETE, WAITING ON IMPACT AO |
| 7/19/23 RESUBMIT RECEIVED, INCOMING COMPLETE. AM |
| 6/26/23 REVIEWS COMPLETE, APPLICANT INVITED TO |
| RESUBMIT AO |
| 6/23/23 IMPACT FEE QUEST UPLOADED. PBCGOV EMAILED |
| AO |
| 6/26/23 - ZONING PASS W PROVISOS. CONTACT PERMIT |
| LIBRARIAN TO PROCESS. LL |
| 5/26/23 PASS FIRE CLF |
| 5/25/23 RESUBMIT RECEIVED, INCOMING COMPLETE. AM |
| 4/21/23 REVIEWS COMPLETE, APPLICANT INVITED TO |
| RESUBMIT AO |
| 4/6/23 - ZONING PASS W PROVISOS. LL |
| 3/31/23 PASS FIRE CLF |
| 3/26/23 RESUBMIT RECEIVED, INCOMING COMPLETE. LEM |
| 3/20/23 RE OPENED CONTRACTOR READY TO RE SUBMIT. |
| DB |
| 3/7/23 ABANDONED APPLICATIO EXPIER FOR CLEAN UP.CD |
| 3/1/22 REVIEWS COMPLETE, APPLICANT NEEDS TO |
| RESUBMIT. LEM |
| 2/15/22 FAILED FIRE CLF |
| THIS PLAN WAS REVIEWED AND FAILED BY CAITLIN L. |
| FRANCIS, FIRE INVESTIGATOR, WITH THE FOLLOWING |
| COMMENTS: |
| 1) RELOCATION OF THE FIRE HYDRANT TO FRONT OF |
| BUILDING PREFERRED FOR OPERATIONAL EFFICIENCY. |
| ? NFPA 1 18.1.3.2 FIRE HYDRANT SYSTEMS. PLANS AND |
| SPECIFICATIONS FOR |
| FIRE HYDRANT SYSTEMS SHALL BE SUBMITTED TO THE |
| FIRE DEPARTMENT |
| FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. |
| |
| 1A) FDC WAS NOT INDICATED ON THE PLANS. FOR |
| OPERATIONAL EFFICIENCY, LOCATE FDC WITHIN 100 FEET |
| OF THE HYDRANT. |
| |
| |
| 2) FIRE SPRINKLER PLANS WERE NOT INDICATED OR |
| INCLUDED IN MASTER. |
| ? FAC 61G15-32.002 DEFINES THE FIRE PROTECTION |
| SYSTEM ENGINEERING DOCUMENT (5) AS WELL AS THE |
| FIRE PROTECTION SYSTEM LAYOUT DOCUMENT (6). |
| 61G15-32.003 OUTLINES THE COMMON REQUIREMENTS TO |
| ALL FIRE PROTECTIONS ENGINEERING DOCUMENTS WITH |
| 32.004 (2) (A-J) OUTLINING THE MINIMUM INFORMATION |
| TO BE PROVIDED ON FIRE PROTECTION ENGINEERING |
| DOCUMENTS FOR WATER-BASED SYSTEMS. AS STATED IN |
| THE DEFINITIONS, THE CONTRACTOR IS TO DEVELOP THE |
| LAYOUT DOCUMENTS BASED ON THE DESIGN CRITERIA |
| PROVIDED IN THE FIRE PROTECTION ENGINEERING |
| DOCUMENTS BY THE ENGINEER OF RECORD FOR THE FIRE |
| SPRINKLER SYSTEM. THE FIRE PROTECTION SYSTEM |
| ENGINEERING DOCUMENTS ARE SUBMITTED FOR THE MASTER |
| PERMIT (BUILDING PERMIT PER FBC) AND THE LAYOUT |
| DOCUMENTS ARE SUBMITTED FOR THE FIRE SPRINKLER |
| INSTALLATION PERMIT. |
| |
| 2A) SEPARATE PERMIT AND SHOP DRAWINGS ARE NEEDED |
| FOR ANY FIRE ALARM, FIRE SPRINKLER AND UNDERGROUND |
| FIRELINE. |
| |
| 3) SHEET E2-1 ELECTRICAL PLAN SHOWS POWER GOING TO |
| EMERGENCY/EXIT SIGN COMBOS BUT DOES NOT INDICATE |
| THE EXIT SIGNS THAT ARE IDENTIFIED ON THE WEST |
| SIDE |
| OF THE SUITES ON SHEET LS1.0 |
| |
| |
| 4) PROVIDE DIMENSIONS FOR DRIVE TO INDICATE |
| ADEQUATE CLEARANCE FOR FIRE DEPARTMENT ACCESS ON |
| SHEET SP1.0. |
| |
| ? NFPA 1 18.2.3.1.1 APPROVED FIRE DEPARTMENT |
| ACCESS ROADS SHALL BE |
| PROVIDED FOR EVERY FACILITY, BUILDING, OR PORTION |
| OF A BUILDING |
| HEREAFTER CONSTRUCTED OR RELOCATED. |
| |
| 5) THERE IS AN INDICATION OF LIGHT FRAME TRUSS |
| TYPE ON SHEET A2.1.1 |
| ?PER F.S. 69A-60.0081 |
| (1) PURPOSE: THE PURPOSE OF THIS RULE IS TO |
| REQUIRE THE PLACEMENT OF AN IDENTIFYING SYMBOL ON |
| STRUCTURES CONSTRUCTED WITH A LIGHT-FRAME TRUSS |
| COMPONENT IN A MANNER SUFFICIENT TO WARN PERSONS |
| CONDUCTING FIRE CONTROL AND OTHER EMERGENCY |
| OPERATIONS OF THE EXISTENCE OF LIGHT-FRAME |
| TRUSS-TYPE CONSTRUCTION IN THE STRUCTURE. |
| (2) DEFINITIONS. |
| (A) ?LIGHT-FRAME TRUSS-TYPE CONSTRUCTION? MEANS A |
| TYPE OF CONSTRUCTION WHOSE PRIMARY STRUCTURAL |
| ELEMENTS ARE FORMED BY A SYSTEM OF REPETITIVE WOOD |
| OR LIGHT GAUGE STEEL FRAMING MEMBERS. |
| (B) ?APPROVED SYMBOL? MEANS A MALTESE CROSS |
| MEASURING 8 INCHES HORIZONTALLY AND 8 INCHES |
| VERTICALLY, OF A BRIGHT RED REFLECTIVE COLOR, |
| DESIGNED IN ACCORDANCE WITH FIGURE 1. |
| (3) ANY COMMERCIAL, INDUSTRIAL, OR MULTIUNIT |
| RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE, |
| WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME |
| TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE |
| MARKED WITH AN APPROVED SYMBOL. TOWNHOUSES ARE NOT |
| MULTIUNIT RESIDENTIAL STRUCTURES AND THEREFORE NOT |
| SUBJECT TO THIS RULE. EACH APPROVED SYMBOL SHALL |
| INCLUDE WITHIN THE CENTER CIRCLE ONE OF THE |
| FOLLOWING DESIGNATIONS: |
| (A) STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL |
| BE MARKED WITH THE LETTER ?R?. |
| (B) STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR |
| SYSTEMS SHALL BE MARKED WITH THE LETTER ?F?. |
| (C) STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND |
| ROOF SYSTEMS SHALL BE MARKED WITH THE LETTERS |
| ?RF.? |
| (4) THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 |
| INCHES TO THE LEFT OF THE MAIN ENTRY DOOR AND: |
| (A) BE PERMANENTLY ATTACHED TO THE FACE OF THE |
| STRUCTURE ON A CONTRASTING BACKGROUND, OR |
| (B) BE MOUNTED ON A CONTRASTING BASE MATERIAL |
| WHICH IS THEN PERMANENTLY ATTACHED TO THE FACE OF |
| THE STRUCTURE. |
| (5) THE DISTANCE ABOVE THE GRADE, WALKING SURFACE |
| OR THE FINISHED FLOOR TO THE BOTTOM OF THE SYMBOL |
| SHALL BE NOT LESS THAN 4 FEET (48 IN.). |
| (6) THE DISTANCE ABOVE THE GRADE, WALKING SURFACE |
| OR THE FINISHED FLOOR TO THE TOP OF THE SYMBOL |
| SHALL BE NOT MORE THAN 6 FEET (72 IN.). |
| (7) IN SINGLE TENANT STRUCTURES WITH MULTIPLE MAIN |
| ENTRY DOORS, SUCH AS BIG BOX RETAIL STORES, |
| DEPARTMENT STORES AND GROCERY STORES, THE |
| AUTHORITY HAVING JURISDICTION IS AUTHORIZED TO |
| REQUIRE THAT OTHER MAIN ENTRY DOORS OF THE |
| STRUCTURE BE MARKED WITH AN APPROVED SYMBOL TO |
| CARRY OUT THE PURPOSE IN SUBSECTION (1) ABOVE. |
| (8) IN MULTIPLE TENANT STRUCTURES AND COVERED MALL |
| STRUCTURES WITH MULTIPLE MAIN ENTRY DOORS, THE |
| AUTHORITY HAVING JURISDICTION IS AUTHORIZED TO |
| REQUIRE THAT OTHER MAIN ENTRY DOORS OF THE |
| STRUCTURE BE MARKED WITH AN APPROVED SYMBOL TO |
| CARRY OUT THE PURPOSE IN SUBSECTION (1) ABOVE. |
| (9) IN MULTIPLE TENANT STRUCTURES AND COVERED |
| MALLS WITH MULTIPLE MAIN ENTRY DOORS, THE |
| AUTHORITY HAVING JURISDICTION IS AUTHORIZED TO |
| REQUIRE THAT OTHER MAIN ENTRY DOORS BE MARKED WITH |
| AN APPROVED SYMBOL TO CARRY OUT THE PURPOSE IN |
| SUBSECTION (1) ABOVE. IN SUCH STRUCTURES, APPROVED |
| SYMBOLS SHALL BE MARKED ON ONE SIDE OF THE |
| STRUCTURE ONLY AND SPACED NOT CLOSER THAN 100 FEET |
| OR AT EACH END OF THE STRUCTURE WHEN SUCH |
| STRUCTURE IS LESS THAN 100 FEET IN LENGTH. |
| (10) THE OWNER OF EACH NEW STRUCTURE REQUIRED TO |
| COMPLY WITH THIS SECTION SHALL MARK THE STRUCTURE |
| WITH THE APPROVED SYMBOL PRIOR TO RECEIVING A |
| CERTIFICATE OF OCCUPANCY. |
| (11) THE OWNER OF EACH EXISTING STRUCTURE REQUIRED |
| TO COMPLY WITH THIS SECTION SHALL MARK THE |
| STRUCTURE WITH THE APPROVED SYMBOL WITHIN 90 DAYS |
| OF THE EFFECTIVE DATE OF THIS RULE. |
| (12) WHERE THE OWNER OF THE STRUCTURE AND THE |
| AUTHORITY HAVING JURISDICTION DISAGREE AS TO THE |
| USE OF LIGHT-FRAME TRUSS-TYPE CONSTRUCTION WITHIN |
| THE STRUCTURE, THE OWNER SHALL BE GRANTED NOT MORE |
| THAN 45 DAYS TO PROVIDE WRITTEN VERIFICATION FROM |
| A LICENSED ENGINEER OR LICENSED ARCHITECT; |
| OTHERWISE, THE OWNER SHALL COMPLY WITH THE RULE. |
| |
| 6) INFORMATIONAL NOTE: ENSURE A ACCESS (KNOX) BOX |
| IS INSTALLED PER NFPA 1: |
| 18.2.2.1 ACCESS BOX(ES). THE AHJ SHALL HAVE THE |
| AUTHORITY TO |
| REQUIRE AN ACCESS BOX(ES) TO BE INSTALLED IN AN |
| ACCESSIBLE LOCATION |
| WHERE ACCESS TO OR WITHIN A STRUCTURE OR AREA IS |
| DIFFICULT |
| BECAUSE OF SECURITY. THE ACCESS BOX(ES) SHALL BE |
| OF AN APPROVED |
| TYPE LISTED IN ACCORDANCE WITH UL 1037. |
| |
| CAITLIN L. FRANCIS |
| FIRE INVESTIGATOR |
| 561-804-4728 |
| [email protected] |
| |
| 2/11/22 - ZONING FAILED. LL |
| 2/7/22 FEES PAID ON 1/24, BACKDATED, INCOMING |
| COMPLETE. LEM |
| 7/7/21 PLANS UPLOADED BUT REJECTED BACK TO |
| APPLICANT AS FILES ARE NOT NAMED PROPERLY, FEES |
| NOT PAID SH |
| 4/27/21 WAITING ON FEES.CD |
| 03/10/21 WAITING ON FEES. CC |
| 03/09/21 APPLICANT INVITED TO UPLOAD PLANS OR |
| DOCUMENTS AND PAY FEES. CC |
| |