| Code Enforcement Detail |
| Case Number |
UX11030067 |
*zones* |
|
| Case Date |
2011-03-02 |
priority |
|
| Type |
|
Status |
C - C |
| Description |
|
Officer |
1685 |
| Operator |
pyusko |
| Property On Case |
| Property ID |
74434322140050170 |
Owner |
LOVE 718 DIXIE LLC |
| Property Address |
718 S DIXIE HWY |
Owner Address |
PO BOX 28 |
| City/State/Zip |
WEST PALM BEACH FL 33401 |
City/State/Zip |
WHITE PLAINS NY 10605 |
|
|
Phone |
|
|
| Case Description |
| THIS 3-STORY, HOLLOW TILE WAREHOUSE HAS FALLEN | | INTO A DILAPIDATED STATE. BEING UNOCCUPIED FOR AN | | ESTIMATED 20 YEARS, AND APPARENTLY UNMAINTAINED | | FOR JUST AS LONG, HAS RESULTED IN A ROOF COVER | | THAT IS NOW ALLOWING WATER TO ENTER THE STRUCTURE. | | THE WATER INFILTRATION IS DAMAGING THE ROOF | | FRAMING, AND WE NOW HAVE MORE THAN ONE MAJOR ROOF | | FRAMING GIRDER READY TO FAIL. THE POTENTIAL FOR | | FAILURE OF THESE GIRDERS COULD LEAD TO FAILURE OF | | OTHER COMPONENTS, SUCH AS THIRD FLOOR FRAMING AND | | EXTERIOR HOLLOW TILE WALL IN THOSE AREAS. THESE | | COMPONENTS WORK TOGETHER AND ARE CRITICAL TO THE | | BUILDING'S LATERAL CUPPORT AND ABILITY TO RESIST | | PERIODS OF STRONG WINDS, SUCH AS A HURRICANE. | | | OTHER AREAS OF THE WAREHOUSE ARE SHOWING TERMITE | | DAMAGE. TERMITES HAVE FOLLOWED THE WATER | | INFILTRATION AND DAMAGED MANY AREAS OF WOOD FLOOR | | FRAMING AND PINE WOOD COVER. | | | THE ELECTRICAL SYSTEM HAS ALSO BEEN DAMAGED BY | | MOISTURE, VANDALISM AND NEGLECT. IT APPEARS TO NO | | LONGER BE STABLE. THE TWO RESTROOMS AND RELATED | | PLUMBING WOULD NEED TO BE REBUILT OR REPLACED. | | | THE BUILDING'S ABILITY TO SAFELY REMAIN UNATTENDED | | HAS CHANGED, AND ITS ABILITY TO WITHSTAND STORMS | | OR PERIODS OF HIGH WIND IS NOW COMPROMISED. THE | | POTENTIAL FOR FAILURE IS PUTTING ALL IN THE | | IMMEDIATE VICINITY IN DANGER AND MUST BE ABATED. |
|
|
|
|
| Violation Code(s) |
| 1: 18-III-202.11(10) -- DANGER,UNSANITARY,FIRE HAZARD |
|
|
| Inspections/Events Detail |
| DATE | TIME | INSPECTION / EVENT TYPE | INSTRUCTIONS / COMMENTS | | 2013-05-27 | 16:13:47 | CLOSE CASE | CLOSE CASE DUE TO DEMOLITION OF STRUCTURE.
| | 2013-05-27 | 16:04:46 | COMMENTS | PER INSPECTOR TOM MOORE, THIS STRUCTURE HAS BEEN DEMOLISHED. THIS CASE IS CLOSED.
| | 2013-05-24 | 16:14:30 | CLOSE CASE | CASE CLOSED BY PYUSKO | | 2011-03-14 | 09:30:25 | INITIAL INSPECTION | THE BUILDING SHOULD BE SECURED FROM ENTRY BY VAGRANTS. THEN A LICENSED ARCHITECT OR ENGINEER SHOULD BE ASKED TO VISIT THE SITE. THEY CAN INSPECT THE INTEGRITY OF THE STRUCTURE AND THE DEGREE OF DETERIORATION. SECURING THE DAMAGED TRUSSES FROM COLLAPSE SHOULD BE A PRIORITY, AND A SHORING PLAN SHOULD BE PUT IN PLACE. THEY WILL THEN BE ABLE TO DESIGN THE APPROPRIATE REPAIRS AND PREPARE THE NECESSARY DRAWINGS. WHEN THE DRAWINGS ARE READY, THEY SHOULD BE SUBMITTED TO CONSTRUCTION SERVICES DEPARTMENT FOR PLAN REVIEW. WHEN THAT IS COMPLETE, A PERMIT TO REPAIR CAN BE ISSUED.
| | 2011-03-02 | 09:50:28 | MAKE A VIOLATION | MAKEVIO RECORDED PYUSKO
| | 2011-03-02 | 09:28:42 | CREATE INITIAL CASE RECORD | COMPLAINT RECORDED BY PYUSKO
|
|
|