Date |
Text |
2023-06-29 15:59:10 | INSUFFICIENT |
| |
| REPEAT COMMENTS: |
| |
| 1. PROVIDE A SURVEY, PREPARED BY A FLORIDA LICENSED |
| SURVEYOR, THAT SHOWS THE RIGHT-OF-WAY LINE, THE |
| SIDEWALK, AND ANY TREES WITHIN THE RIGHT-OF-WAY ALONG |
| THE FIBER CONDUIT PATH SO THAT STAFF CAN VERIFY THAT |
| THE BORE AND ANY REQUIRED BORE PITS AND HANDHOLES ARE |
| WITHIN THE PUBLIC RIGHT-OF-WAY. THE SURVEY NEEDS TO |
| INCLUDE THE LOCATION OF CONDUIT, PROPOSED HANDHOLES, |
| AND THE BORE SECTIONS. IN ORDER TO INSTALL HANDHOLES |
| AND BORE UNDER PRIVATE PROPERTY THE SCOPE OF WORK MUST |
| BE WITHIN A GENERAL UTILITY EASEMENT. THIS GENERAL |
| UTILITY EASEMENT MUST BE CLEARLY SHOWN ON THE SURVEY. |
| |
| [NEW COMMENT 3.21.23] CONDUIT APPEARS TO CROSS OVER |
| PRIVATE PROPERTY AT CORNER INTERSECTION OF CLEARWATER |
| AND AUSTRALIAN. PLEASE SHOW EASEMENT GRANTING THIS |
| CROSSING. |
| |
| [UPDATE 6.29.23] THANK YOU FOR PROVIDING SURVEY |
| SECTIONS, PLEASE OVERLAY FIBER CONDUIT PATH AS WELL AS |
| ANY HANDHOLES OR BOREPITS ON THE SURVEY. |
| |
| 2. THE TUBULAR MARKERS ARE NOT PERMITTED. MARKERS MAY |
| ONLY BE INSTALLED WITHIN THE HANDHOLES OR OTHERWISE |
| BURIED. |
| |
| 3. PROVIDE A COPY OF THE FDOT PERMIT APPROVING THE WORK |
| WITHIN THEIR RIGHT-OF-WAY. |
| |
| 4. ANY BOREPITS, HANDHOLES, OR EXCAVATION WORK SHALL |
| PROVIDE AN 8FT. BUFFER FROM THE TRUNK OF THE TREE TO |
| REDUCE THE RISK TO ROOT SYSTEMS. PLEASE PROVIDE |
| DIMENSIONS FROM ANY TREES ADJACENT TO EXCAVATIONS. |
| |
| |
| CHRIS KIMMERLY, AICP |
| URBAN DESIGN PLANNER |
| 822.1426 [email protected] |
| |