2019-10-07 18:16:40INSUFFICIENT
  
 PLEASE SEE THE LIST BELOW FOR AN ANALYSIS OF THE
 DEFICIENCIES IN INFORMATION REQUIRED BY SECTION 78-401
 OF THE CITY OF WEST PALM BEACH CODE AS PART OF THE
 COMMUNICATION FACILITIES PLACEMENT PERMIT APPLICATION.
 THE DEFICIENT INFORMATION MUST BE PROVIDED FOR STAFF TO
 REVIEW THE PERMIT APPLICATION. PLEASE NOTE THAT STAFF
 HAS ALSO INCLUDED SOME SUBSTANTIVE REVIEW COMMENTS,
 THAT WHILE NOT RESULTING IN A DEFICIENT APPLICATION,
 NEED TO BE ADDRESSED OR THE PERMIT WILL NOT BE
 APPROVED.
  
 1) ENGINEERING PLAN
  
 A. THE SUBMITTED ENGINEERING PLAN MUST BE BASED ON THE
 REQUIRED SURVEYS.
  
 B. THERE IS A DISCREPANCY IN YOUR APPLICATION AND PLANS
 AS TO WHETHER THIS IS A NEW POLE OR MOUNTING ON AN
 EXISTING POLE.
  
 C. IF THIS IS A NEW POLE, THEN THE SIZE OF THE PROPOSED
 POLE BASE WITHIN THE RIGHT-OF-WAY MUST BE SHOWN ON THE
 ENGINEERING PLAN.
  
 D. IF THIS IS A MOUNTING ON AN EXISTING POLE, THEN YOU
 MUST SUBMIT A STRUCTURAL CAPACITY REPORT FOR THE
 SUPPORT STRUCTURE, AS EVIDENCED BY A SEALED STATEMENT
 FROM A STRUCTURAL ENGINEER LICENSED IN THE STATE OF
 FLORIDA, THAT THE POLE CAN SUPPORT THE PROPOSED
 ELEMENTS.
  
 2) SURVEY OF UNDERGROUND FACILITIES - THE BASE OF THE
 POLE IS BEING INSTALLED UNDERGROUND SO THIS IS
 REQUIRED.
  
 A. ALL UNDERGROUND UTILITIES NEED TO BE PROVIDED ON A
 SURVEY PREPARED BY A FLORIDA LICENSED SURVEYOR.
  
 B. THE ENGINEERING PLAN MUST BE BASED OFF OF THIS
 SURVEY INFORMATION.
  
 3) SURVEY OF ABOVEGROUND FACILITIES - A NEW POLE IS
 BEING USED OR INSTALLED ABOVEGROUND SO THIS IS
 REQUIRED. PLEASE NOTE THAT YOU ARE REQUIRED TO VERIFY
 THE POLE OWNERSHIP AND INCLUDE THE INFORMATION ON THE
 SURVEY.
  
 A. IDENTIFY ALL ABOVEGROUND FEATURES TO INCLUDE TREES
 ON A SURVEY PREPARED BY A FLORIDA LICENSED SURVEYOR.
  
 B. IDENTIFY ALL ABOVEGROUND COMMUNICATION FACILITIES IN
 THE AREA TO INCLUDE AN INVENTORY OF THE REGISTRANT'S
 EXISTING FACILITIES - NO INFORMATION ON EXISTING
 FACILITIES WAS PROVIDED. SHOW THIS INFORMATION ON THE
 PLANS AND PROVIDE A NARRATIVE. IF THERE ARE NO
 FACILITIES, THIS SHALL BE NOTED ON THE SURVEY.
  
 C. YOU ARE REQUIRED TO PROVIDE INFORMATION REGARDING
 EXISTING UTILITY POLES (INCLUDING LIGHT POLES) WITHIN
 50 FEET OF YOUR PROPOSED POLE. THE POLE HEIGHT AND BASE
 DIAMETER SHALL BE INCLUDED. PLEASE NOTE: THE SUPPORT
 POLE INCLUDED WITH THIS APPLICATION IS 43 FEET ABOVE
 GRADE IN HEIGHT. WITHOUT THE INFORMATION REGARDING THE
 SURROUNDING POLE HEIGHTS, STAFF CANNOT DETERMINE IF IT
 COMPLIES WITH THE HEIGHT STANDARDS LISTED IN SECTION
 78-411(G)(1) OF THE CITY CODE.
  
 D. THE ENGINEERING PLAN MUST BE BASED OFF OF THIS
 SURVEY INFORMATION.
  
 4) CONCEALMENT METHODS DESCRIPTIONS - NO CONCEALMENT
 INFORMATION WAS PROVIDED. REGARDLESS OF IF THIS IS A
 NEW POLE OR ATTACHMENT TO AN EXISTING POLE, THE
 EXTERIOR CABLES, NON-CONCEALED ANTENNAS AND A REMOTE
 EQUIPMENT CABINET DO NOT COMPLY WITH THE CONCEALMENT
 STANDARDS OUTLINED IN SECTION 78-411 OF THE CITY CODE.
 THE POLE ELEVATION MUST INCLUDE ALL THE DIMENSIONS.
 PLEASE NOTE THAT NON-CONCEALED ATTACHMENTS ARE ONLY
 PERMITTED ON ELECTRICAL TRANSMISSION POLES AND LIGHT
 POLES, WHICH THIS POLE IS NOT.
  
 5) CONSTRUCTION TIMETABLE - YOU MUST PROVIDE AN
 ESTIMATED TIMETABLE FOR CONSTRUCTION OF THE PROJECT.
  
 6) RESTORATION ESTIMATE - YOU MUST PROVIDE A
 RESTORATION ESTIMATE.
  
 7) RADIO FREQUENCY INTERFERENCE - NO INFORMATION WAS
 PROVIDED THAT THE PROPOSED FACILITIES WILL NOT CAUSE
 RADIO FREQUENCY INTERFERENCE WITH THE CITY'S PUBLIC
 SAFETY COMMUNICATIONS EQUIPMENT. PROVIDE A STATEMENT
 REGARDING RADIO FREQUENCY INTERFERENCE.
  
 8) EVIDENCE OF INSURANCE COVERAGE - YOU ARE REQUIRED TO
 SUBMIT VERIFICATION OF INSURANCE IN ACCORDANCE WITH THE
 PROVISIONS OF SECTION 78-406 OF THE CITY CODE OF
 ORDINANCES.
  
 9) START OF OPERATION - AN ATTESTATION FROM THE
 COMMUNICATIONS FACILITIES SERVICE PROVIDER THAT
 COMMUNICATIONS SERVICES FACILITIES WILL BE INSTALLED
 AND OPERATIONAL ON THE PROPOSED STRUCTURE NO LATER THAN
 NINE MONTHS AFTER THE DATE THE APPLICATION IS APPROVED
 IS REQUIRED. PROVIDE THE REQUIRED ATTESTATION.
  
 10) PUBLIC UTILITY LETTERS, TELEPHONE, NATURAL GAS,
 ELECTRIC SERVICE, AND TELEVISION CABLE - THE PUBLIC
 UTILITY LETTERS WERE NOT PROVIDED. PROVIDE COPIES OF
 THE PUBLIC UTILITY LETTERS.
  
 11) ELECTRONIC FORMAT OF SUBMITTAL - THE SUBMITTAL WAS
 NOT PROVIDED IN ELECTRONIC FORM. A COPY OF ALL OF THE
 SUBMITTAL MATERIAL MUST BE SUBMITTED IN ELECTRONIC
 FORMAT.
  
 12) PROVIDER CLARIFICATION - ON THE COMMUNICATIONS
 FACILITIES PLACEMENT PERMIT APPLICATION, YOU MARKED
 THAT THIS IS A PASS THROUGH PROVIDER, YET YOU HAVE ALSO
 MARKED THAT YOU ARE A COMMUNICATION SERVICES PROVIDER
 THAT REMITS TAXES TO THE CITY. BY CITY DEFINITION, YOU
 CANNOT BE BOTH. IF YOU ARE A PASS THROUGH PROVIDER, YOU
 ARE REQUIRED TO PAY AN APPLICATION FEE TO THE CITY.
  
 13) POLE OWNER APPROVAL - THE APPROVAL FROM THE OWNER
 OF THE POLE PERMITTING THE INSTALLATION OF A FACILITY
 WAS NOT PROVIDED. PLEASE NOTE THAT IF THIS IS BEING
 INSTALLED ON A CITY POLE, THEN FEE IS REQUIRED TO BE
 PAID TO THE CITY.
  