Date |
Text |
2021-04-07 16:32:15 | DENIED |
| |
| PERMIT 19020199 - UNDERGROUND FIBER FLAGLER AND FERN |
| MCIMETRO PROJECT #1806CQB.1 3/25/21 RESUBMITTAL |
| |
| PROVIDE WRITTEN RESPONSE TO COMMENTS. |
| |
| THE FOLLOWING ITEMS NEED TO BE ADDRESSED OR THE PERMIT |
| WILL NOT BE APPROVED. |
| |
| 1) ENGINEERING PLAN - REPEAT COMMENT: THE REVISED BORE |
| LOCATION INCLUDES A CROSSING OF FERN STREET WHICH |
| INCLUDES A PROPOSED OPEN CUT, THREE FEET DEEP, LEADING |
| TO HANDHOLE 8+95. THE LOCATION OF THE PROPOSED OPEN CUT |
| IS AN AREA THAT INCLUDES BIOSWALE PITS THAT ARE |
| SURROUNDED BY STRUCTURAL SOIL. THE STRUCTURAL SOIL HAS |
| EXACTING INSTALLATION STANDARDS AND MAY NOT BE |
| DISTURBED. STAFF PROVIDED THE AS ENGINEERING DRAWINGS |
| SHOWING A DETAIL FOR THE BIOSWALE PIT WITH THE |
| SURROUNDING STRUCTURAL SOIL. THE FULL AREA COVERED BY |
| THE STRUCTURAL SOIL UNDER THE SIDEWALK IS A MINIMUM OF |
| 19 FEET EAST TO WEST AND THE FULL DEPTH OF THE SIDEWALK |
| FROM THE CURB TO THE EDGE OF THE RIGHT-OF-WAY LINE. THE |
| DETAILS ARE PROVIDED ON SHEET C1.10 OF THE DRAWINGS. |
| |
| IT APPEARS THAT YOU SHIFTED THE BIOSWALE PIT TO THE |
| EAST OF HANDHOLE STA 8+95; HOWEVER, THE DIMENSION FROM |
| THE LIMITS OF THE STRUCTURAL SOIL TO THE EDGE OF WHERE |
| YOU WILL CUT THE SIDEWALK TO SET THE HANDHOLE WAS NOT |
| PROVIDED. THIS DIMENSION MUST BE AT LEAST SEVEN (7) |
| FEET TO AVOID DISTURBING THE STRUCTURAL SOIL AND |
| CLEARLY SHOWN ON THE PLAN (A BLOW UP OF THE AREA OF |
| WORK WOULD BE BEST). |
| |
| THE FIBER LEADING TO THE WEST SIDE OF STA 8+95 WAS NOT |
| CHANGED AND CONTINUES TO SHOW AN OPEN CUT THROUGH THE |
| STRUCTURAL SOIL BOTH TO THE WEST OF THE BIOSWALE PIT |
| AND BETWEEN THE BIOSWALE PIT AND THE EDGE OF THE |
| RIGHT-OF-WAY. STAFF WILL NOT SUPPORT THIS PROPOSAL AS |
| IT WILL DAMAGE THE STRUCTURAL SOIL. |
| |
| AFTER THE SEVEN FOOT OFFSET FROM EACH OF THE BIOSWALE |
| PITS TO AVOID THE STRUCTURAL SOIL, THERE WILL BE AN |
| APPROXIMATELY 15 FOOT CLEAR AREA WHERE YOU CAN INSTALL |
| THE HANDHOLE AND THE FUTURE SMALL CELL WIRELESS |
| FACILITY POLE. YOU WILL NEED TO BORE DIRECTLY FROM THE |
| HANDHOLE STA 8+00 TO HANDHOLE STA 8+95 UNDER FERN |
| STREET. |
| |
| 2) THE SURVEY FOR THE INTERSECTION OF N CLEMATIS STREET |
| AND FLAGLER DRIVE DOES NOT INCLUDE THE RIGHT-OF-WAY |
| LINE, THE CURB LINE OR OTHER FEATURES. |
| |
| PLEASE NOTE: |
| |
| THE INSTALLATION CONTRACTOR MUST CONTACT SUNSHINE 811 |
| TO VERIFY THE LOCATION OF ALL UTILITIES AND VERIFY ALL |
| DEPTHS PRIOR TO CONSTRUCTION. ALL CITY UTILITIES MUST |
| BE LOCATED BY SOFT DIG METHODS BEFORE STARTING THE |
| WORK. |
| |
| THE RIGHT-OF-WAY USE PERMIT REQUIRES YOU TO PROVIDE A |
| CERTIFICATE OF LIABILITY INSURANCE, WHICH IN ACCORDANCE |
| WITH SECTION 78-406 OF THE CITY CODE SPECIFICALLY NAMES |
| THE CITY OF WEST PALM BEACH, ITS COMMISSIONERS, |
| OFFICERS, EMPLOYEES AND AGENTS AS ADDITIONAL INSURED. |
| |
| CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| [email protected] |
| |