Plan Review Notes
Plan Review Notes For Permit 19020199
Permit Number 19020199
Review Stop Z
Sequence Number 5
Notes
Date Text
2021-04-07 16:32:15DENIED
  
 PERMIT 19020199 - UNDERGROUND FIBER FLAGLER AND FERN
 MCIMETRO PROJECT #1806CQB.1 3/25/21 RESUBMITTAL
  
 PROVIDE WRITTEN RESPONSE TO COMMENTS.
  
 THE FOLLOWING ITEMS NEED TO BE ADDRESSED OR THE PERMIT
 WILL NOT BE APPROVED.
  
 1) ENGINEERING PLAN - REPEAT COMMENT: THE REVISED BORE
 LOCATION INCLUDES A CROSSING OF FERN STREET WHICH
 INCLUDES A PROPOSED OPEN CUT, THREE FEET DEEP, LEADING
 TO HANDHOLE 8+95. THE LOCATION OF THE PROPOSED OPEN CUT
 IS AN AREA THAT INCLUDES BIOSWALE PITS THAT ARE
 SURROUNDED BY STRUCTURAL SOIL. THE STRUCTURAL SOIL HAS
 EXACTING INSTALLATION STANDARDS AND MAY NOT BE
 DISTURBED. STAFF PROVIDED THE AS ENGINEERING DRAWINGS
 SHOWING A DETAIL FOR THE BIOSWALE PIT WITH THE
 SURROUNDING STRUCTURAL SOIL. THE FULL AREA COVERED BY
 THE STRUCTURAL SOIL UNDER THE SIDEWALK IS A MINIMUM OF
 19 FEET EAST TO WEST AND THE FULL DEPTH OF THE SIDEWALK
 FROM THE CURB TO THE EDGE OF THE RIGHT-OF-WAY LINE. THE
 DETAILS ARE PROVIDED ON SHEET C1.10 OF THE DRAWINGS.
  
 IT APPEARS THAT YOU SHIFTED THE BIOSWALE PIT TO THE
 EAST OF HANDHOLE STA 8+95; HOWEVER, THE DIMENSION FROM
 THE LIMITS OF THE STRUCTURAL SOIL TO THE EDGE OF WHERE
 YOU WILL CUT THE SIDEWALK TO SET THE HANDHOLE WAS NOT
 PROVIDED. THIS DIMENSION MUST BE AT LEAST SEVEN (7)
 FEET TO AVOID DISTURBING THE STRUCTURAL SOIL AND
 CLEARLY SHOWN ON THE PLAN (A BLOW UP OF THE AREA OF
 WORK WOULD BE BEST).
  
 THE FIBER LEADING TO THE WEST SIDE OF STA 8+95 WAS NOT
 CHANGED AND CONTINUES TO SHOW AN OPEN CUT THROUGH THE
 STRUCTURAL SOIL BOTH TO THE WEST OF THE BIOSWALE PIT
 AND BETWEEN THE BIOSWALE PIT AND THE EDGE OF THE
 RIGHT-OF-WAY. STAFF WILL NOT SUPPORT THIS PROPOSAL AS
 IT WILL DAMAGE THE STRUCTURAL SOIL.
  
 AFTER THE SEVEN FOOT OFFSET FROM EACH OF THE BIOSWALE
 PITS TO AVOID THE STRUCTURAL SOIL, THERE WILL BE AN
 APPROXIMATELY 15 FOOT CLEAR AREA WHERE YOU CAN INSTALL
 THE HANDHOLE AND THE FUTURE SMALL CELL WIRELESS
 FACILITY POLE. YOU WILL NEED TO BORE DIRECTLY FROM THE
 HANDHOLE STA 8+00 TO HANDHOLE STA 8+95 UNDER FERN
 STREET.
  
 2) THE SURVEY FOR THE INTERSECTION OF N CLEMATIS STREET
 AND FLAGLER DRIVE DOES NOT INCLUDE THE RIGHT-OF-WAY
 LINE, THE CURB LINE OR OTHER FEATURES.
  
 PLEASE NOTE:
  
 THE INSTALLATION CONTRACTOR MUST CONTACT SUNSHINE 811
 TO VERIFY THE LOCATION OF ALL UTILITIES AND VERIFY ALL
 DEPTHS PRIOR TO CONSTRUCTION. ALL CITY UTILITIES MUST
 BE LOCATED BY SOFT DIG METHODS BEFORE STARTING THE
 WORK.
  
 THE RIGHT-OF-WAY USE PERMIT REQUIRES YOU TO PROVIDE A
 CERTIFICATE OF LIABILITY INSURANCE, WHICH IN ACCORDANCE
 WITH SECTION 78-406 OF THE CITY CODE SPECIFICALLY NAMES
 THE CITY OF WEST PALM BEACH, ITS COMMISSIONERS,
 OFFICERS, EMPLOYEES AND AGENTS AS ADDITIONAL INSURED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved